To change user code:  

Switch to programming mode in security keyboard:

 

1.  Press 

 and 

 and 

 start blinking. 

2.  Bring installer’s key near the keypad. You will hear a short signal tone and only  

 blinks. 

3.  Key  in  installer  code  1234  and  press 

.  You  will  hear  a  long  signal  tone  and 

  starts 

blinking. 

To program a new user code: 

4.  Press 

, and 

 starts blinking. 

5.  Press 

 and 

 continues blinking. 

6.  Key in a new 4 digit code. Press 

 . 

 continues blinking. 

7.  Repeat the new 4 digit code you just entered. Press 

 is on for one second after which 

you  will  hear  a  long  signal  tone.  Note!  Setting  the  user  code  to  0000  removes  the  user  code 
altogether. 

Exit programming mode: 

8.  Press 

 and 

. The security keypad returns to normal user mode. 

 

Note:  Go  through  the  aforementioned  steps  in  one  succession  without  interruption  –  otherwise  the 
security keypad will return to user mode automatically after awhile and the user code is not changed. 

3.15 Heater Relay 

You can use HCE+ for controlling heating in your house. You can control an individual heater or an 
entire heating system with HCE+. 

 

 

Connect the heater to the central unit (HEATER 
relay). 

Note: You cannot control heating from your 
mobile phone if manual control is turned on. 

Important: Make sure that max load 230VAC/10A is not exceeded under any circumstances. 

Important: When relay is used to steer inductive load (for example, another contactor), connect 
RC filter or EMC suppression component in parallel to load to stop voltage spikes when 
contactor releases. Voltage spike may break the relay. 

3.16 EXT Relay 

There is a second relay in HCE+ (EXT) and its use can be selected freely. You can also set this relay to 
auto mode when it follows device’s operating mode. If monitoring is on (ALARM ON), the relay pulls and 
when monitoring is off (ALARM OFF), the relay releases. This allows you to easily switch off electricity 
and close water pipe when leaving home. 

EXT relay can also be used as a LEAKGUARD. When moisture sensor detects moisture, the EXT relay 
pulls. The relay releases when leakguard is disabled or reset. When leakguard is in use, you cannot set 
the relay on or off with EXT command. 

EN 

FUN 

EN 

EN 

EN 

EN 

FUN 

EN 

EN 

FUN 

Summary of Contents for HouseControl E+

Page 1: ...ANUAL 1 0 HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY SECURITY KEYPAD WITH PROXIMITY TAGS PREVENTION OF WATER DAMAGES WIRELESS EXTENSIONS ...

Page 2: ......

Page 3: ...ector model Motion sensor model Magnetic door switches Remote camera Security keypad Siren Installed by We assure that the alarm system was installed in accordance with the manufacturer s instructions that the alarm system has been tested and it works as documented that the end user has received guidance as to how to use the alarm system Location and date Installed by Signature This form needs to ...

Page 4: ......

Page 5: ...MOTE CAMERA 6 3 6 INDOOR TEMPERATURE SENSOR 6 3 7 OUTDOOR TEMPERATURE SENSOR 6 3 8 WATER TEMPERATURE SENSOR 7 3 9 SIREN 7 3 10 MAGNETIC DOOR SWITCHES 7 3 11 MOISTURE SENSOR 8 3 12 MOTION SENSOR 8 3 13 SMOKE DETECTOR 9 3 14 SECURITY KEYPAD 10 3 15 HEATER RELAY 11 3 16 EXT RELAY 11 3 17 POWER SUPPLY AND BATTERY BACKUP UNIT 12 3 18 SIM CARD 12 3 19 WIRELESS EXTENSION 13 4 SETUP AND TESTING 13 4 1 TES...

Page 6: ...munications operator for testing and using HouseControl You must disable the PIN code request from the SIM card before inserting the card in the central unit It is recommended that testing is conducted with the same SIM card that will remain in the central unit after the installation is complete If a camera is installed you should make sure that MMS messages messages that contain pictures can be s...

Page 7: ...ctor HCE Wireless extension detectors and remote controls Magnetic door switch flush and surface mounting Temperature sensors Battery Moisture sensor Battery backup unit package Central unit package Check the package contents Central unit Magnetic door switch flush mounting 2 temperature sensors Siren Motion sensor Smoke detector Battery backup unit And Materials needed in installation Installatio...

Page 8: ...ter Aircon relay see 3 3 2 Ext relay see 3 3 3 Camera and data connector 4 Inputs for temperature sensors siren magnetic door switches moisture sensor motion sensor smoke detector security keypad and 12V power supply see 3 3 5 Cable holder 6 SIM card slot 7 Power switch 8 Tamper switch 9 Manual heating switch red light is on when manual control is used 10 Door security on off switch 3 3 Connectors...

Page 9: ...r switch or without the motion sensor being able to detect the trespasser You must have an access to the central unit if you intend to use door security at night The signal light on the security keypad tells the current operating mode is monitoring on or off Drill holes for the cables on the wall Leave at least 30 cm of surplus length to the cables to make installation easier Push surplus cable ba...

Page 10: ...tom 3 6 Indoor Temperature Sensor Place the indoor temperature sensor in the living area in an unnoticeable place Run the cable behind a baseboard to the HCE Note Do not leave sensors uninstalled Shorten cables as needed and install temp1 and temp2 sensors inside HCE so that there will be no unnecessary temperature alarms Place the temperature sensor in the area where you want to measure temperatu...

Page 11: ...ust not exceed 300mA 12VDC Fasten the siren with the screws included in the package Connect the siren to the Siren connector as depicted in the separate wiring diagram Notice polarity black and red wires 3 10 Magnetic Door Switches Connect magnetic door switches in series as shown in the separate wiring diagram Install them in doors and windows that are most usually left open by accident This prev...

Page 12: ...ll the sensor under a bypass manifold or a dishwasher If there is a leakage in the water pipe water will flow in the casing pipe and come out near the bypass manifold and eventually end up in the floor drain By placing the moisture sensor under the bypass manifold you can detect leakages easily Tape the sensor to the floor Hide the excess of the cable Connect the moisture sensor to the Water conne...

Page 13: ...r ceiling Hide the surplus of the cable Connect the motion sensor to the IR connector as depicted in the separate wiring diagram 3 13 Smoke Detector The smoke detector should be attached to the ceiling Do not place the detector in a corner or cranny because then it will not detect smoke so easily Note You can connect up to 8 smoke detectors in the fire connector in HCE Open the cover cerefully by ...

Page 14: ...ode alarm on off Installer s key cannot be used for this purpose Operating mode can also be changed by using a secret code The codes are attached to the installer s key To program security keypad for example if you want to change individual codes you need installer s key and installer s code 1234 Do not change the installer code because if installer s proximity key is lost you cannot program the s...

Page 15: ... house You can control an individual heater or an entire heating system with HCE Connect the heater to the central unit HEATER relay Note You cannot control heating from your mobile phone if manual control is turned on Important Make sure that max load 230VAC 10A is not exceeded under any circumstances Important When relay is used to steer inductive load for example another contactor connect RC fi...

Page 16: ...e battery 3 Attach the battery to the casing with two sided tape 4 Connect the mains cable Make sure the HCE works even if you detach the mains cable from the wall outlet This proves that the battery has been connected properly and the 4A fuse is ok 3 18 SIM Card First disable the PIN code request from the SIM card Make sure the power is switched off from the HCE power switch is OFF see picture be...

Page 17: ...M card in the central unit Switch power ON and leave the cover open Wait 30 seconds for the HCE to start up The unit s status light starts blinking as it goes into programming mode If the light does not blink make sure the PIN code request is disabled from the SIM card the GSM connection has been opened by your operator the GSM signal strength is sufficient in the area and that the SIM card was pl...

Page 18: ... the detector as instructed by the manufacturer Wait until you receive an alarm message Send ALARM OFF to the unit to clear alarms 6 Enabling remote camera Send CAMERA ON message to the unit and then ask report from the unit with command Check that the camera is enabled CAMERA ON from the report 7 Taking pictures with remote camera You must tell HouseControl the multimedia settings MMS of the part...

Page 19: ..._______________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ ____________...

Page 20: ..._______________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ ____...

Page 21: ...SETUP AND TESTING 17 ...

Page 22: ...18 HouseControl E Installation Manual Isoharjantie 6 Tel 358 20 728 8740 71800 Siilinjärvi Fax 358 17 462 1212 FINLAND info telemic fi http www telemic net ...

Reviews: