V1.1
9
II. Setting of Dome Device communication
Before installation and use, the setting of communication protocol and transmission speed (baud rate)
should comply with the control system.
1
.
Setting protocol and baud rate of dome device.
On/Off
status
Protocol type
1
st
digit
2
nd
digit
3
rd
digit
4
th
digit
5
th
digit
6
th
digit
PELCO-D
ON
ON
OFF
OFF
**
**
PELCO-P
OFF
OFF
ON
OFF
**
**
TeleEye DM2
ON
ON
ON
OFF
**
**
协
议
设
置
波
特
率
设
置
拔
码
开
关
拔
码
开
关
拔
码
开
关
拔
码
开
关
Dome device
controller
Image
displayer
Power
of dome
AC24V
Video
Image
displayer
Power
of dome
AC24V
Video
Image
display
Power
of dome
AC24V
Video
Dome #1
Dome #2
Dome #N
RS-485
RS-485
RS-485
RS-485 Bus
(Wiring of multi-dome)
O
n
/O
ff
sw
itch
B
a
u
d
ra
te
se
tti
n
g
P
ro
to
co
l se
tti
n
g
Summary of Contents for DM597
Page 12: ...V1 1 11...