![Teledyne TIENet 360 LaserFlow Ex Installation And Operation Manual Download Page 18](http://html1.mh-extra.com/html/teledyne/tienet-360-laserflow-ex/tienet-360-laserflow-ex_installation-and-operation-manual_1080370018.webp)
TIENet™ 360 LaserFlow™ Velocity Sensor
Section 1 Introduction
1-4
1.5 Technical
Specifications
Table 1-1 provides technical specifications for the LaserFlow.
Table 1-1 LaserFlow Sensor Specifications
a
Size (H x W x D)
38.01 x 26.21 x 56.7 cm
14.96 x 10.3 x 22.32 in
Cable Lengths
b
10 or 23 m
32.8 or 75.5 ft
The maximum recommended distance between the Laser-
Flow and the Signature® flow meter is 45.7 meters (150
feet). The maximum recommended distance between the
LaserFlow and the 2160 LaserFlow module is 23 meters
(75.5 feet).
Weight (LaserFlow w/ built-in sensor, 10 m cable)
Sensor w/o built-in sensor, 10 m cable
LaserFlow w/ built-in sensor, 350 AV Sensor
8.7 kg
19.2 lbs
8.25 kg
18.2 lbs
9 kg
20 lbs
Materials
Conductive Carbon Filled ABS Plastic, SST, Conductive
Kynar®
c
, Anodized Aluminum, UV Rated PVC
Enclosure (self-certified)
IP68 (Submerged @ 2 m depth for 72 hrs)
Certifications
CE EN61326; FDA CDRH 21CFR1040; IEC 60825-1
Laser Class
Class 3R
Laser Wavelength
655 nm
Laser Exit Angle
45° ±3°
Power (from connected flow meter/module)
Input voltage range: 8 to 26VDC; 12VDC Nominal
Electrical Connections
Signature Flow Meter
Screw Terminal
2160 LaserFlow Module
TIENet
™
Plug
Temperature Range
Operating:
-20 to 60 °C
-4 to 140 °F
Storage:
-40 to 60 °C
-40 to 140 °F
Flow Accuracy
±4% of Reading (Typical under normal flow conditions)
Velocity Measurement
Technology
Non-Contact, Subsurface Laser Doppler Velocity
(U.S. patent 8,339,584 and patents pending)
Measurement Range
-4.6 to + 4.6 m/sec
-15 to +15 ft/sec
Number of velocity readings per measurement
1 to 15 (selectable measurement points)
Maximum distance: liquid surface to bottom of sensor
3m (10 ft)
Minimum depth for velocity measurement
0.01m (0.5 in)
Direction
Selectable Bi-Directional Measurement
d
Minimum Velocity
0.15 m/s
0.5 ft/s
Deadband
Zero deadband from bottom of LaserFlow sensor
d
Accuracy
±0.5% of reading ±0.03 m/s (0.1 ft/s)
Summary of Contents for TIENet 360 LaserFlow Ex
Page 2: ......
Page 4: ......
Page 10: ...TIENet 360 LaserFlow Velocity Sensor Safety viii ...
Page 54: ...TIENet 360 LaserFlow Velocity Sensor Section 2 Preparation and Installation 2 32 ...
Page 90: ...TIENet 360 LaserFlow Velocity Sensor Section 4 Setup with 2160 LaserFlow Module 4 20 ...
Page 102: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 2 A 2 LaserFlow Sensor ...
Page 103: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 3 ...
Page 104: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 4 ...
Page 105: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 5 ...
Page 106: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 6 ...
Page 107: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 7 ...
Page 109: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 9 ...
Page 111: ...TIENet 360 LaserFlow Velocity Sensor Appendix A Replacement Parts A 11 ...
Page 132: ...TIENet 360 LaserFlow Velocity Sensor D 6 ...
Page 136: ......
Page 138: ...Warranty ...
Page 140: ......