T3PS Series Programming Manual
36
F-72 = 1
Set to 8 data bits.
F-73 = 0
Parity to none.
F-74 = 0
1 Stop bit.
F-75 = 1
Set the UART TCP to TDK
(emulation mode).
F-76 = 00~30
Set the address of each slave to a
unique address identifier
8.
Multiple units can now be operated at the same
time. Only legacy commands can be used in
this mode. See the programming manual or see
the function check below for usage details.
Slave serial link
cable with RJ-45
shielded
connectors
RS-485 slave serial link pin assignment
8 Pin Connector (IN)
8 Pin Connector (OUT)
Pin No.
Name
Pin No.
Name
Housing
Shield
Housing
Shield
1
SG
1
SG
6
TXD -
6
TXD -
3
TXD +
3
TXD +
5
RXD -
5
RXD -
4
RXD +
4
RXD +
1 8