T3PS Series Programming Manual
24
Display memory
parameter when recalling
(M1, M2, M3)
F-15
0 = OFF, 1 = ON
Auto Calibration Parallel
Control
F-16
0 = Disable, 1 = Enable, 2 = Execute
Parallel Calibration and set to Enable.
Note: Must be a short between each
unit before starting.
Measurement Average
Setting
F-17
0 = Low, 1 = Middle, 2 = High
Alarm Recovery and
Output Status
F-18
0 = Safe Mode, 1 = Force Mode
Lock Mode
F-19
0:Lock Panel, Allow Output OFF
1:Lock Panel, Allow Output ON/OFF
USB Settings
Show front panel USB
status
F-20
0 = None, 1 = Mass Storage
Show rear panel USB
status
F-21
0 = None, 1 = Linking to PC
Setup rear USB Speed
F-22
0 = Disable USB, 1 = Full Speed, 2 =
Auto Detect Speed
SCPI Emulation
F-26
0 = Teledyne LeCroy, 1 = TDK GEN, 2
= Agilent 5700, 3 = Kikusui PWX, 4 =
AMREL SPS
LAN Settings
Show MAC Address-1
F-30
0x00-0xFF
Show MAC Address-2
F-31
0x00-0xFF
Show MAC Address-3
F-32
0x00-0xFF
Show MAC Address-4
F-33
0x00-0xFF
Show MAC Address-5
F-34
0x00-0xFF
Show MAC Address-6
F-35
0x00-0xFF
LAN Enable
F-36
0 = OFF, 1 = ON
DHCP
F-37
0 = OFF, 1 = ON
IP Address-1
F-39
0-255
IP Address-2
F-40
0-255
IP Address-3
F-41
0-255
IP Address-4
F-42
0-255
Subnet Mask-1
F-43
0-255
Subnet Mask-2
F-44
0-255
Subnet Mask-3
F-45
0-255
Subnet Mask-4
F-46
0-255