Teledyne PDS - Teledyne PDS, T20-P and POS MV Quick Setup
Configuration
21
Figure 3-3
I/O pane serial clock setting
4. Set-up the POS MV to output a serial time ZDA message. Refer to
the POS MV configuration’s section ‘Serial time message output’ on
page 27.
3.4.2.2 Ethernet Time Message
When a time message from the POS MV by Ethernet is used it is not
necessary to connect the serial cable to the T20-P COM1 timing port. The
PPS ports are still connected to each other.
Refer to section ‘Connections’ on page 3.
Perform the following steps:
1.
Open the SUI I/O pane and select ‘Network’ as protocol. Settings are
changed by selecting the field and selecting the value from the drop
down list. See Figure 3-4.
Figure 3-4
Changing the serial protocol into network
2. Setup the settings as indicated in Figure 3-5.
Select port type
Network
and the POS MV Ethernet 7 message.
Select as protocol UDP/IP with local port 5602. Set the host
address with the IP address of the POS M
V. Tick the ‘Check host
address’ checkbox.