April
2018
Pathfinder DVL Guide
Page 204
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Table 46:
Sensor Source for Doppler Processing Output Format
Binary
Bytes
Field
Description
28
SOS Status
A value of 0 indicates no valid data; A value of 1 indicates sensor data valid from
sensor specified by EZ; A value of 2 indicates sensor data valid from alternate
sensor or user input.
29-30
SOS Source
See notes, below.
31-34
Temperature
Temperature in 1/100ths of a °C.
35
Temperature
Status
A value of 0 indicates no valid data; A value of 1 indicates sensor data valid from
sensor specified by EZ; A value of 2 indicates sensor data valid from alternate
sensor or user input.
36-37
Temperature
Source
See notes, below.
38-41
Salinity
Salinity in parts-per-ten thousand
42
Salinity Status A value of 0 indicates no valid data; A value of 1 indicates sensor data valid from
sensor specified by EZ; A value of 2 indicates sensor data valid from alternate
sensor or user input.
43-44
Salinity Source See notes, below.
45-48
Depth
Depth in centimeters
49
Depth Status
A value of 0 indicates no valid data; A value of 1 indicates sensor data valid from
sensor specified by EZ; A value of 2 indicates sensor data valid from alternate
sensor or user input.
50-51
Depth Source
See notes, below.
52-55
Pressure
Pressure in kPa.
56
Pressure Sta-
tus
A value of 0 indicates no valid data; A value of 1 indicates sensor data valid from
sensor specified by EZ; A value of 2 indicates sensor data valid from alternate
sensor or user input.
57-58
Pressure
Source
See notes, below.
59-62
Ensemble
Timer Ticks
Timer Ticks Recorded when the RTC clock was read at the start of the ensemble.
Intended for use in matching sensor TimeTags to RTC based ensemble time.
This data corresponds to the last ping of the ensemble for those sensors sampled at ping
intervals. It is intended for single ping ensembles.
Output of this data is controlled by the 7
th
bit of the EE command (
The sensor source is identified by the detailed list of sensors in the table of the main text or
the #EY description (
EY – Sensor Source Override for Doppler Parameters
). In addition to the
sensors in that command, a sensor ID of -1 indicates that the parameter has been calculated
based on other parameters (for example, speed of sound calculated based on salinity,
pressure and temperature). A sensor ID of 0 indicates the parameter is from a user input
command.