6712SR Refrigereated Sampler
Section 7 Remote Operation
7-8
3. If the command is valid for its current state of operation,
the sampler responds with “[command number], please
acknowledge.” If the command is not valid the sampler
responds with the command number followed by three
quick beeps. Enter a valid command.
4. Acknowledge the valid command by pressing the number.
For the example, press
.
5. If the number is incorrect, the sampler responds with your
entry followed by three quick beeps. You must re-enter the
command (step 2).
6. After the command is confirmed, the sampler replies with
“[command number] acknowledge” and executes the com-
mand.
To enter additional commands, repeat steps two through five.
The sampler will hang up after ten seconds of quiet time.
1
Table 7-4 6712 Remote Commands
Phone
Command
Name
Description
Start
This command will start immediately any program that has been run and is
currently waiting to start.
Load and Run
Program 1
This command will load Program 1 as the sampler’s current Extended pro-
gram, reset partition if the storage interval has been changed, and run the pro-
gram. RUN1 is valid when the sampler is in standby, or when it is waiting for a
start command. RUN1 will also run the current program while in Standard pro-
gramming.
Load and Run
Program 2, 3, or 4
These commands will load the selected program number as the sampler’s cur-
rent Extended program, reset partition data if the storage interval has
changed, and run the program. They are valid when the sampler is in standby,
or when it is waiting for a start command. The commands are available for
Extended programming only.
Disable
This command is similar in functionality to a pin F low signal (a signal typically
used to enable or disable the sampler from a flow meter). At run time, the sam-
pler starts with the phone enable in the enabled state. PHONE DISABLE is
valid while a program is running. If successful, a reply of REMOTE ENABLE IS
FALSE will be returned.
A Remote Disable is the highest priority disable. If the sample is disabled with
this command, no condition other than command 6#, ENABLE, will allow the
program to become enabled again.
Enable
This command is used to re-enable a phone-disabled sampler. PHONE
ENABLE is valid while a program is running. If successful, a reply of REMOTE
ENABLE IS TRUE will be returned.
Grab Sample
This command causes the sampler currently running a program to take a sam-
ple. The sample will count as one of the program’s samples and is placed in
the current bottle (Part A’s current bottle when using two-part programming).
TAKE_SAMPLE is valid while the program is running, after the start time, but
not while in the MANUAL PAUSE screens. If successful, a response similar to
PUMPING XXML SAMPLE INTO BOTTLE ## will be returned. If not, a
response similar to NO SAMPLE, PROGRAM WAITING START will be
returned.
0
#
1
#
2
#
3
#
4
#
5
#
6
#
7
#
Summary of Contents for 6712SR
Page 2: ......
Page 4: ......
Page 14: ...6712SR Refrigerated Sampler Table of Contents xii ...
Page 28: ...6712SR Refrigerated Sampler Section 1 Introduction 1 14 ...
Page 42: ...6712SR Refrigerated Sampler Section 2 Installation Preparation 2 14 ...
Page 54: ...6712SR Refrigerated Sampler Section 3 Getting Started 3 12 ...
Page 140: ...6712SR Refrigerated Sampler Section 6 SDI 12 Sondes 6 8 ...
Page 188: ...6712SR Refrigerated Sampler Appendix A Menu Flowcharts A 24 ...
Page 196: ...6712SR Refrigerated Sampler Appendix B Material Safety Data Sheets B 8 ...
Page 206: ...6712SR Refrigerated Sampler Appendix D Replacement Parts D 2 ...
Page 207: ...6712SR Refrigerated Sampler Appendix D Replacement Parts D 3 ...
Page 208: ...6712SR Refrigerated Sampler Appendix D Replacement Parts D 4 Locknut 10 32 Screw 10 32 x 3 4 ...
Page 209: ...6712SR Refrigerated Sampler Appendix D Replacement Parts D 5 ...
Page 210: ...6712SR Refrigerated Sampler Appendix D Replacement Parts D 6 ...
Page 211: ...6712SR Refrigerated Sampler Appendix D Replacement Parts D 7 ...
Page 212: ...6712SR Refrigerated Sampler Appendix D Replacement Parts D 8 ...
Page 218: ...6712SR Refrigerated Sampler Appendix E Accessories List E 6 ...
Page 222: ...6712SR Refrigerated Sampler Index Index 4 ...
Page 224: ......