User Manual 

OE6250G-M 

Optical-Electrical 

Converter 

 

Summary of Contents for Everywhereyoulook OE6250G-M

Page 1: ...User Manual OE6250G M Optical Electrical Converter...

Page 2: ...unauthorized duplication of Teledyne LeCroy documentation materials is strictly prohibited Teledyne LeCroy is a registered trademark of Teledyne LeCroy Inc Other product or brand names are trademarks...

Page 3: ...ures 1 Compatibility 1 Safety 2 Operation 3 Connecting the Unit 3 Controlling from the Oscilloscope 4 Care and Maintenance 6 Cleaning the Converter Body 6 Cleaning and Connecting Optical Fibers 6 Cali...

Page 4: ...authorized service centers within this period However in order to do this we must first examine the product and find that it is defective due to workmanship or materials and not due to misuse neglect...

Page 5: ...ce the OE6250G M becomes an integrated part of the oscilloscope The Optical wavelength dark calibration and reference receiver functions are all controlled from the oscilloscope s touch screen The osc...

Page 6: ...always clean the optical connector and ensure the facet is free from dirt or impurities See the instructions on p 6 Do not install or terminate fibers while a light source is active Care must be taken...

Page 7: ...e and pushing until you hear a click 2 Connect one end of the 2 92 mm cable to the 2 92 mm connector on the OE6250G M and the other to the 2 92 mm connector on the oscilloscope 3 Clean and connect the...

Page 8: ...set signal without any light present in the optical receiver The Set to Zero function resets the Dark Calibration value to zero The Dark Level field allows manual entry of the Dark Level offset this w...

Page 9: ...dB OE6250G M Nominal Compensated Response 4th order Bessel Thomson response Flatness opimized response Optical Wavelength The optical wavelength of the OE6250G M can be selected between 830 nm and 160...

Page 10: ...it to the port If the fiber is dirty clean it as follows 1 Gently wipe the fiber end with a lint free swab dipped in isopropyl alcohol 2 Use compressed air to dry it completely 3 Visually inspect the...

Page 11: ...he power connector is plugged in and locked and that the 2 92mm cable is connected Service Defective products must be returned to a Teledyne LeCroy service facility for diagnosis and repair or replace...

Page 12: ...requirements to Directives 2012 19 EU on Waste Electrical and Electronic Equipment WEEE For more information about proper disposal and recycling of your Teledyne LeCroy product visit teledynelecroy c...