Telect 009-8005-1404 Installation Manual Download Page 5

Dual 200A 4/5 TPA/GMT Fuse Alarm Panel  
with Bay Alarms 

Installation Guide 

 

 

 

 

© Telect, Inc. All rights reserved. 126152-5 5.3.17  
509.926.6000 :: www.telect.com 

 

1.3 Specifications 

 

Inputs:  

Specifications:  

Voltages & range 

+/- 24 VDC, +/- 20V to +/- 30V 
-48 VDC, -40V to -60V 

Max. input load rating  

200A per side  

Nominal power dissipation at  
full load  

70W per side @ 9600W full load per side (200A x 48V) 

Percentage of full load power 
dissipation at nominal voltage 

Less than 1% 

Max. input interrupt device 

250A 

Input terminal studs (with split ring 
lock washers & nuts) for  
dual-hole compression lugs 

Two pairs of ¼ -20 studs on ¾ in. centers. Torque nut (using 7/16 
in. or 12 mm socket) to ~45 in. -lb. (~5 N

m). 

Input wire size  

#8 to 250MCM AWG (depends on input interrupt device) 

 

 

TPA Outputs:  

Specifications:  

Max. TPA output fuse (ea.) 

50A 

Max. TPA output load  
(ea.) 

– continuous 

40A 

Max. total TPA output load  

160A per side  

TPA output terminal studs with nuts 

16, single, #10 

– 32 studs, max. lug width of 0.46 in. (1.17 cm). 

Torque nut using 3/8 in. or 10 mm socket to ~20 in.-lb.  
(~2.3 N

m) 

TPA output wire size  

#18 to #6 AWG (depends on output fuse rating) 

 

 

Grounding:  

Specifications:  

Earth GND terminal studs (with split 
ring lock washers & hex nuts) for 
dual-hole compression lug 

Two pair of ¼ - 

20 threaded holes on ⅝ in. (1.59 cm) centers. 

Torque supplied bolt (using 7/16 in. or 12 mm socket) to 4 ft-lb  
(5.42 N

m) 

Ground wire size  

Up to #4 AWG (depends on input interrupt device) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 009-8005-1404

Page 1: ...Dual 200A 4 5 TPA GMT Fuse Alarm Panel with Bay Alarms Installation Guide ...

Page 2: ...us quo and looks beyond what is possible in network connectivity and power management Founded in 1982 Telect is driven by the principles of innovation and customer service Headquartered in Liberty Lake WA the privately held company supports a global network of customers with a comprehensive product portfolio and a values driven corporate culture Our products and solutions are found across communic...

Page 3: ...hematic Drawing 11 1 7 Assembly Drawing 12 List of Figures Figure 1 Model 009 8005 1404 1 Figure 2 Bracket Orientation 4 Figure 3 Rack Mounting 4 Figure 4 Ground Lug Connection 5 Figure 5 Input Lugs 5 Figure 6 Disengaging a TPA Fuse Holder 6 Figure 7 Alarm Indicators 6 Figure 8 Alarm Terminals 6 Figure 9 TPA Output Lug Connections 7 Figure 10 GMT Output Lug Connections 7 Figure 11 Installing TPA F...

Page 4: ...t accessories and replaceable parts output fuses 3A 50A TPA A 15A GMT dummy fuses lugs ETSI mounting kit and more Model 009 8005 1404 is UL listed File E 139903 V1 S9 1 2 Inspection Please read these instructions carefully before beginning installation If you need assistance call Technical Support at 509 926 6000 or email Telect at getinfo telect com Inspect equipment after unpacking and compare i...

Page 5: ...in centers Torque nut using 7 16 in or 12 mm socket to 45 in lb 5 N m Input wire size 8 to 250MCM AWG depends on input interrupt device TPA Outputs Specifications Max TPA output fuse ea 50A Max TPA output load ea continuous 40A Max total TPA output load 160A per side TPA output terminal studs with nuts 16 single 10 32 studs max lug width of 0 46 in 1 17 cm Torque nut using 3 8 in or 10 mm socket t...

Page 6: ...on output fuse rating Alarms Specifications Alarm relay contacts 2A 30 VDC 0 6A 60 VDC Max alarm card power rating 20V 85mA 1 70W 24V 103 mA 2 47W 27V 109 mA 2 94W 30V 112 mA 3 36W 42V 123 mA 5 17W 48V 128 mA 6 14W 56V 135 mA 7 56W 60V 139 mA 8 34W Alarm wire size 24 AWG type 26 to 20 AWG Alarm terminals Wire wrap Dimensions Specifications Nominal without brackets Width Height Depth See Page 12 fo...

Page 7: ...ing in a 19 in rack 1 If necessary remove the three screws and reposition re align the brackets on the sides of the distribution panel as shown in Figure 2 2 Locate an unused rack position and mount the panel using the four screws and lock washers provided as shown in Figure 3 It s best to mount the panel as high as possible on the rack 3 Tighten the screws to 35 in lb 4 29 N m 4 Loosen you need n...

Page 8: ...he panel is turned off 10 Make sure the input power is off open breaker dummy fuse open fuse holder at power distribution unit or PDU before connecting this panel s input cables to the PDU 11 For input wiring wiring used as inputs to this distribution panel crimp the dual hole compression lugs onto 8 AWG to 250MCM copper wires 12 Insulate lug barrels with UL94 V 0 rated heat shrink tubing 13 Clean...

Page 9: ...erminals See Figure 8 for location 19 With PWR ON A lit normal operation but with PWR ON B LED off failure operation test the power fail relay and contacts at the PWR ALM terminals on the rear of the panel Expect an open circuit Ω between Terminals C and NC Expect continuity 0Ω between Terminals C and NO 20 Also test the fuse alarm relay contacts at the FUSE ALARM terminals on rear of the panel Fo...

Page 10: ...ETURN terminals before connecting lugs to the terminals as shown in Figure 9 NEC specifies only one lug and load at each output terminal 27 Tighten nuts to 20 in lb 2 3 N m and then connect the other end of output wire to load 28 For GMT output wiring use 20 to 12 AWG copper wire Work with one wire at a time At the panel end of the wire either Crimp a single hole ring or fork lug as required by NE...

Page 11: ...use pull out the TPA fuse carrier and insert an operable fuse as shown in Figure 11 For a GMT fuse pull out dummy fuse and insert operable fuse as shown in Figure 12 33 Check the voltage and polarity at the input of each equipment load 34 If possible Temporarily replace one of the operable TPA fuses with a blown fuse to check that the FUSE ALARM and the TPA Fuse LEDs light red Also check the FUSE ...

Page 12: ...inal to corresponding R return terminal of CRIT MAJ and MIN When each pair of A and R terminals are jumpered Expect CRIT and MAJ LEDs to turn red and MIN to turn amber Expect an open circuit Ω between C and NC of each set of terminals when the relays are activated Expect continuity 0Ω between Terminals C and NO when relays are activated 38 Connect A and R pairs to appropriate corresponding dry con...

Page 13: ...Y ALARM LEDs Contacts 400547 TPA Fuses 5A 124818 10A 124819 15A 124820 20A 124821 30A 122734 40A 122738 50A 122739 GMT Fuses A Violet VIO 100151 A Red RED 004001 A Brown BRN 004008 1A Gray GRY 100991 1 A White WHT 004006 1 A White Yellow WHT YEL 004011 2A Orange ORN 004002 3A Blue BLU 004012 4A White Brown WHT BRN 004013 5A Green GRN 004014 7 A Black White BLK WHT 004010 10A Red White RED WHT 0040...

Page 14: ...M BAY ALARMS CONTACTS ACTIVATE NO NO NC C NC NC NO C C A A R R REMOVEABLE ALARM CARD BATT RTN RTN BATT 1 2 3 4 1 2 3 4 1 2 19 20 1 2 19 20 1 2 19 20 1 2 19 20 1 2 3 4 1 2 3 4 TPA OUTPUT BATT A INPUT A TPA OUTPUT RTN A GMT OUTPUT BATT A GMT OUTPUT RTN A GMT OUTPUT RTN B GMT OUTPUT BATT B TPA OUTPUT RTN B TPA OUTPUT BATT B INPUT B POWER ON A POWER ON B TPA GMT FUSE ALARM CR MJ MN TPA FUSE HOLDER LED...

Page 15: ...s described herein are subject to change without notice 8 36 Stud Nut Use 5 16 Socket 1 4 20 Stud 6 Panhead NOTES 1 Dimensions are in or in cm cm in 2 Panel not supplied with fuses REAR VIEW ROTATED TOP VIEW FRONT VIEW Universal Bracket Reversed for 23 Rack Holes Accommodate EIA WECO Mounting Patterns Pull Out Designation Card Below Replacable Alarm Board 1 72 4 37 1 00 2 54 23 00 58 42 22 31 56 6...

Reviews: