GB
Special needs Manual
Commissioning with analogue basic electronics
GB
40
www.behnke-online.com
3.5. Set-up example
*0000
▸ Enter set-up mode
21 telephone no. Button 1 #
▸ Enter the telephone no. for the first button
09 10 #
▸ set the open door time interval (5 to 90 seconds)
10 0 #
▸ Set 0 as the code to open the door
53 4 #
▸ Play message 4 when opening the door
56 5 #
▸ Play message 5 when opening the door after a keypad
entry
58 1 2 6 #
▸ Play message 1 before establishing connection
Play message 2 while waiting for the call to be picked up
Play message 6 to the called party,
In case this message will not be necessary, enter the following
setting: 58 1 2 0 #
*
▸ Exit set-up mode
*0000
▸ Enter set-up mode
21 telephone no. Key 1 *800# (00 can be replaced by voice messages,
see configuration steps from page 41)
09 10#
▸ set the open door time interval (5 to 90 seconds)
10 0#
▸ Set 0 as the code to open the door
*
▸ Exit set-up mode
3.6. Set-up example with function *800 (waiting for the call to be answered, here
without voice messages)
In this example, the special needs module button is connected to the flat ribbon plug on T1. Relay 1
(here: door opener) is activated for 10 seconds. Messages 1, 2 and 6 are played during events.