Teleco TVDMM868A05 Manual Download Page 14

14

Warnings

IMPORTANT! READ THIS INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND 

COMMISSIONING THE PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

PRODUCT INSTALLATION

The product at issue must be installed, commissioned and maintained only by licensed and authorised people, respecting 

the laws concerning the electrical installations. Not conforming installations, wrong adjustments or product alterations may 

cause fire, electric shock, or personal injuries. The manufacturer is not responsible for any damage due to wrong installation 

or improper use. 

Attention:

 at the power-on the device resumes the status it had before the turning-off.

MOUNTING LOCATION AND MODALITY

The product must be mounted applying the following indications carefully:

•  it must be

 fixed on surfaces which cannot be damaged by the high temperature.

•  it must be 

placed in a well ventilated location. It cannot be hermetically closed.

•  it must be

 fixed vertically, with cable glands downward.

•  connection cables 

must be

 protected against any accidental impacts, using proper pipes. 

•  do not cover

 the product.

•  do not 

use or store flammable materials close to the product.

ELECTRICAL CONNECTIONS 

All the connections must be rated for a single-phase 110/230Vac power supply, with the relative Earth connection. For the 

disconnection from the power line, use an all-pole switch with contacts having a dimension of at least 3,5mm. Arrange 

all 

the necessary safety devices 

and use only materials complying with the standard of electrical installations. Signal and 

power voltage wiring (110/230Vac) must be separated one from the other. The cable must have a section properly rated 

according to the load connected and a nominal temperature range (T) up to 90°C. The following table reports (roughly) the 

resistance values and the maximum current of a copper wire, according to its length:

 Section (mm2)  

R (ohm/Km)    Max. current (A)

 

 

   19.5   

 

5

 

1.5 

 

   13.3   

 

10

 

2.5 

 

   7.98   

 

16

WARNING: If any cable is damaged, it must be immediately replaced by a qualified person in order to avoid any hazard.

SAFETY INFORMATION

This  appliance  is  not  intended  for  use  by  people  (including  children)  with  reduced  physical,  sensory  or  mental

capabilities, or not properly informed about the product’s characteristics or the possible hazards it can cause. 

Children should be carefully supervised when they are in the area of the product. Do not touch the electronic board 

with  wet  hands,  any  metallic  or  flammable  objects.  Do  not  operate  in  the  high  voltage  area  of  the  electronic  board, 

when it is supplied. Do not touch the heatsink, for at least 15 minutes after the switching off of the product. Use the 

product  only  in  combination  with  devices  which  can  guarantee  a  safe  extended  time  functioning. 

The radio signal 

reception of the device could be disturbed by the presence of electrical disturbances being transmitted by 

other appliances working on the same frequency or  if the product is somehow shielded by metal parts.
PRODUCT DISPOSAL

At the end of this product’s useful life, it must not be disposed of as domestic waste, but must be taken to a collection 

centre for waste electrical and electronic equipment. It is the user’s responsibility to dispose of this appliance through the

appropriate channels at the end of its useful life. 
Hereby Teleco automation s.r.l. declares that the product complies with the essential requirements and other relevant 

provisions, established by the Directive 1999/5/EC. The declaration of conformity can be consulted on the web site: 

www.telecoautomation.com/ce. 

In the view of a constant development of their products, the manufacturer reserves the 

right for changing technical data and features without prior notice.

Summary of Contents for TVDMM868A05

Page 1: ...utput Maximum power each output 230Vac 50 60Hz 110Vac 50 60Hz 25W R 25VA L C 7W Led 12W R 12VA L C 4W Led 500W R 500VA L C 100W Led 250W R 250VA L C 50W Led Characteristics Suitable for any type of lo...

Page 2: ...7 GND for L3 8 GND for L4 M3 9 10 Load L1 11 12 wired input T1 M4 13 14 Load L2 15 16 wired input T2 M5 17 18 Load L3 19 20 wired input T3 M6 21 22 Load L4 23 24 wired input T4 T1 T2 T3 T4 ON OFF and...

Page 3: ...TTING DIP Output 1 2 3 4 see p 4 P1 ON OFF Dim P2 memorize TX P3 delete TX P4 output selection SELECTED OUTPUT Output 1 2 3 4 ON output selected by means of P4 button or associated to the received rad...

Page 4: ...ying perform the procedure of fine adjustment see par 3 3 page 13 keeping the dip switch configuration as it is In case of a later modification of the load type it might be necessary adjusting the min...

Page 5: ...he button P4 the selection will be indicated by the relative led ON 1 2 Memorization of one transmitter button with On Off Dim function With short impulses turn the load on and off keeping it pressed...

Page 6: ...by the relative led ON 2 Press the button P2 four times and hold it down the fourth one the buzzer will make a beep each time and then sounds continuously 3 During the beep sound press the button of...

Page 7: ...he button P4 the selection will be indicated by the relative led ON 2 Press the button P2 seven times and hold it down the seventh one the buzzer will make a beep each time and then sounds continuousl...

Page 8: ...TS the 2 channels of TVTXSxx and TVTXLR02x can be assigned to the preset values of activation 100 recognized movement 66 NO movement which are CH1 and CH2 of a 7 channel transmitter see the procedure...

Page 9: ...t and each of them must have different values of intensity when a preset scene is commanded it is necessary to clearly identify the output which relative preset will be modified This is possible in di...

Page 10: ...the selected output will change its intensity Press P4 to select the output OR Press Adjust Adjust Keep pressed to DIM 5 sec press 5 sec press b The 4 7 42 channel transmitter is associated to more th...

Page 11: ...nual The new transmitter will have the same functions of the transmitter used for its memorization Press P3 Press Press c The 4 7 42 channel transmitter is associated to more than one output as MASTER...

Page 12: ...y 1 Clean the output selection using P4 Output LED must be all OFF 2 Press the button P3 two times and hold it down for 10 sec the buzzer will make one beep and then sound quickly and intermittently 3...

Page 13: ...hold them down Press P4 to select the output Press P4 to select the output Press P1 P2 P3 once and hold them down Press P4 to select the output 1 Select the output using P4 2 Press P1 P3 and hold the...

Page 14: ...e reports roughly the resistance values and the maximum current of a copper wire according to its length Section mm2 R ohm Km Max current A 1 19 5 5 1 5 13 3 10 2 5 7 98 16 WARNING If any cable is dam...

Page 15: ...utput Power 2000W 500W for each output at 230Vac 1000W 250W for each output at 110Vac Reception frequency 868 3 MHz TVDMM868A05 916 MHz TVDMM916A05 Operating temperature range 20 45 C The maximum numb...

Page 16: ......

Reviews: