7
2.3 CONTROL UNIT DIAGRAM
1 - High voltage terminals
2 - Low voltage terminals
3 - 3.15A fuse
4 - Aerial connection
5 - Programming/command buttons
6 - Dip switches
7 - Status/alarm LED
8 - LED courtesy light
9 - Socket for radio card (MASTER)
10 - Alarm buzzer output
11 - Manoeuvre relays
12 - Common relay
13 - Transformer
14 - Ground terminal
2.4 ELECTRICAL CONNECTIONS
High voltage terminals
#
CONNECTION
1
Motor Ground
2
240V
~
Power supply - Ground
3
240V
~
Power supply IN - LIVE
4
240V
~
Power supply IN - NEUTRAL
5
Motor - OPEN
6
Motor - COMMON
7
Motor - CLOSE
8
240V
~
COURTESY LIGHT
(300W max. lamp)
9
#
CONNECTION
16
Infrared/8K2 safety edge input (brown)
17
Infrared/8K2 safety edge input (green)
18
Infrared/8K2 safety edge input (white)
19
Push-button common (COM)
20
Push-button (step-by-step, N.O.)
21
Emergency STOP push-button (N.C.)
22
Emergency STOP push-button common
Wired
infrared/8K2
safety edge
Emergency
STOP (TB)
TB
COM
COM
TD
Via dell'Artigianato, 16 - 31014 Colle Umberto (TV) ITALY
Tel. +39.0438.388511 Fax +39.0438.388536
Web site: www.telecoautomation.com
DATE: 02/03/17
REV: 1.0
ETI-MORS-RDSB02
Da stampare a colori
Low voltage terminals
Push-
button
(TD)
see pag. 8 for
connections
Open COM Close
MOTOR
240V
Line IN
GND
Via dell'Artigianato, 16 - 31014 Colle Umberto (TV) ITALY
Tel. +39.0438.388511 Fax +39.0438.388536
Web site: www.telecoautomation.com
DATE: 02/03/17
REV: 1.0
ETI-MORS-RDSB02
Da stampare a colori
L N
Courtesy
light
output
GSM
1
4
5
2
3
6
7
8
9
10
11
13
12
14
3 4 5 6 7 8 9
12 13 14 15 16 17 18 19 20 21 22