Model 458-3SL (3-Slot Chassis) Rev A
Page 12
Status Byte Register
Bit Value Set
Operation
0
1 0 Not
Supported
1
2 0 Not
Supported
2
4 0 Not
Supported
3
8 0 Not
Supported
4
16
1
Enable Message Available bit (MAV)
5
32
1
Enable Event Status Bit (ESB)
6
64
1
MSS this bit is always enabled
7 128 0
Not
Supported
Event Status Enable Register
Bit Value Set
Operation
0
1 1 Operation
Complete
1
2 0 Not
Supported
2
4 1 Query
Error
3
8 0 Not
Supported
4 16 1
Execution
Error
5 32 1
Command
Error
6 64 0
Not
Supported
7 128 1
Power
On
Set Length command
:setcard:length:LM:H:LE,C
Where:
LM = Module slot number
Æ
01 - 02 (458-2SL) 01 – 03 (458-3SL) or 01 – 16 (458-CM)
H = Channel number
Æ
1 - 8
LE = Length (in feet)
C = Connect mode:
N = connect both CO and CPE ends.
P = connect CPE only CO is open.
O = connect CO only CPE is open.
Z = open both CO and CPE ends
Example: :setcard:length:01:1:2000,n sets channel 1 of the line module in slot 1 to 2000 ft.