Telcoma STONE 300 GR Installation Manual Download Page 4

IO 18/E Rev. 00 

 

SPARE PARTS 

 

PART  QTy  CODE  DESCRIPTION 

PART  Q.TY 

CODE 

DESCRIPTION 

100645  REDUCTION GEAR COVER LF. BLACK 

20 

100715 

BLACK ALUMINIUM TUBE 400mm STROKE 

100644  REDUCTION GEAR COVER RG. BLACK

 

20 

100763 

GREY ALUMINIUM TUBE 400mm STROKE

 

100759  REDUCTION GEAR COVER LF. GREY 

20 

100739 

BLACK ALUMINIUM TUBE 600mm STROKE

 

100758  REDUCTION GEAR COVER RG. GREY

 

20 

100764 

GREY ALUMINIUM TUBE 600mm STROKE

 

100647  MOTOR CASING RG. BLACK

 

21 

100829 

PISTON ROD GUIDE 

100761  MOTOR CASING RG. GREY

 

22 

100625 

SCRAPER RING 

100840  STATOR 220V 4 POLES 45mm 1400rpm 

23 

100827 

PISTON ROD LOCK NUT 

100651  IRREVERSIBLE MOTOR SHAFT 

24 

100828 

FEMALE SCREW 

100841  ROTOR 45mm 

25 

100823 

WALL BRACKET 

100278  BEARING 6202 ZZ 

26 

100705 

GRUB SCREW M14X10 

100706  HELASTIC RING E15 

27 

100646 

ALUMINIUM PISTON ROD TERMINAL BLACK 

100291  BEARING 6202 2RS 

27 

100906 

ALUMINIUM PISTON ROD TERMINAL GREY 

10 

100650  IRREVERSIBLE TOOTH WHEEL 

28 

100624 

ALUMINIUM UNCLAMPING 

11 

100789  HELASTIC RING E20 

29 

100657 

O-RING 

12 

100709  BEARING 6004 ZZ 

30 

100825 

GATE BRACKET 

13 

100658  TOWING BALL 

31 

100654 

PIN 

14 

100655  UNCLAMPING PIN 

32 

100218 

UNCLAMPING KEY 

15 

100641  UNCLAMPING SPRING 

33 

100707 

BEARING 6003 ZZ 

17 

100661  ALUMINIUM LOCK NUT  

34 

100184 

CAPACITOR 8µF 

17 

 

100909  FIBRE LOCK NUT  

35 

100755 

UNCLAMPING CAP 

19 

100712  STAINLESS STEEL TUBE 300mm STROKE 

36 

100748 

CABLE PRESS 

19 

100713  STAINLESS STEEL TUBE 400mm STROKE  37 + 40 

 100998  ENDLESS SCREW 40 + release shaft 

19 

100738  STAINLESS STEEL TUBE 600mm STROKE  37 + 40

 

 100998  ENDLESS SCREW 50 + release shaft 

20 

100714  BLACK ALUMINIUM TUBE 300mm STROKE  37 + 40

 

 100998  ENDLESS SCREW 70 + release shaft 

20 

100762  GREY ALUMINIUM TUBE 300mm STROKE 

38 

100313 

CAP SCREW M5X16 

 

    

      

 

CARDIN ELETTRONICA Spa 

Via Del Lavoro, 73 

31013 Codognè, Fraz. Cimavilla TV 

Tel. +39 0438 404011 Fax. +39 0438 401831 

www.cardin.it

 

 

Summary of Contents for STONE 300 GR

Page 1: ...ety devices must be installed at a height not exceeding 70cm from the ground and at a distance from the floor movement of the door of no more than 20cm Their proper functioning of the photocells must be verified at the end of installation according to Section 7 2 1 of EN12445 Keep the activation controls of automation out of reach of children The controls should be installed at a minimum 1 5m heig...

Page 2: ... that the gate has a rather solid structure and that there is no friction points in its movement 3 Make sure that the leaf is suitably balanced even after the installation of the gear motor 4 Check that the electrical installation is in accordance with the characteristic required by the gear motor TECHINICAL DATA SCHEDULED MAINTENANCE DESCRIPTION FREQUENCY ENTRUSTED OPERATION Photocells cleaning M...

Page 3: ...ix it with the bolt 6 With gate s leaf closed turn and slide the screw of gear motor s D shaft until the end of the stroke 7 Screw D shaft back on 1 complete turn of 360º picture5 8 Place B support plate in the hole of D shaft and position it against the gate leaf Fix it to the gate leaf taking in account the inclination point nr 3 9 Proceed in the same way with the other gate leaf 10 Connect the ...

Page 4: ...00291 BEARING 6202 2RS 27 1 100906 ALUMINIUM PISTON ROD TERMINAL GREY 10 1 100650 IRREVERSIBLE TOOTH WHEEL 28 1 100624 ALUMINIUM UNCLAMPING 11 2 100789 HELASTIC RING E20 29 2 100657 O RING 12 1 100709 BEARING 6004 ZZ 30 1 100825 GATE BRACKET 13 2 100658 TOWING BALL 31 2 100654 PIN 14 1 100655 UNCLAMPING PIN 32 1 100218 UNCLAMPING KEY 15 1 100641 UNCLAMPING SPRING 33 1 100707 BEARING 6003 ZZ 17 1 1...

Page 5: ... importanti Pagina 3 Collegamento elettrico Pagine 3 4 Procedura di programmazione Pagine 5 6 Comando via radio Pagina 7 Modalità di funzionamento Pagina 7 Indicazioni del display Pagina 7 Caratteristiche tecniche Pagina 28 230 Vac Motors PROGRAMMATORE ELETTRONICO PER IL COMANDO DI PORTE E PORTONI MOTORIZZATI ELECTRONIC PROGRAMMER CONTROLLING MOTORISED GATES AND DOORS PROGRAMMATEURÉLECTRONIQUE POU...

Page 6: ...ogrammation CENTRAL DE MANDO PARA 1 O 2 MOTORES DE 230 V Instrucciones de uso y programación ELECTRONIC CONTROL UNIT FOR 1 or 2 230V MOTORS Programming and user instructions STEUERZENTRALE FÜR 1 2 MOTOREN MIT 230V Gebrauchs und Programmierungsanweisungen BESTURINGSKAST VOOR 1 2 230V MOTOREN Gebruiksaanwijzing en programmeerinstructies I F E GB D NL mod T600 ...

Page 7: ...1 2 28 29 P1 P P STOP PA Spia PC P2 PED Led 3 4 5 8 6 9 10 12 14 15 16 18 19 20 13 17 11 22 21 23 26 27 24 25 7 Art XXXOC2 Art TAST 3F 30 32 31 MEMORIA Fig A 1 7 ...

Page 8: ...222 190 150 50 118 280 220 Fig B mm 8 ...

Page 9: ...e 230V M1 M2 M1 M2 Com Com C CAP M1 CAP M1 ENC ENC Encoder Encoder Spia LAMP Luce C AP AP NO CH CH NC 25 45 26 46 27 47 D D D D 6 7 8 9 10 11 12 13 3 3 4 4 5 5 2 1 BSC BSC BSC BSA BSA Com 0 BSA FT 1 FT 2 JOLLY 1 JOLLY 2 STOP PEDONALE APRE CHIUDE 230V 50Hz LINEA ALIMENTAZIONE F6 3A 230V F2A 24V 8K2 8K2 8K2 8K2 39 Rx ANT 14 15 Com 0 PASSO PASSO 230V TR1 12 0 24 14 0 mod T600 Fig C 9 ...

Page 10: ...M1 Com Com C CAP M1 CAP M2 ENC ENC Spia LAMP Luce C AP AP NO CH CH NC 25 45 26 46 27 47 D D 6 7 8 9 10 11 12 13 3 4 5 2 1 BSC Com 0 1 2 3 4 5 6 7 BSA FT 1 FT 2 FT 1 FT 2 J1 J 2 STP PED PA PC 39 Rx ANT Rx ANT 14 15 Com 0 P P P1 P P P2 PED Linea Alim 230V 50Hz TX TX RX RX Couple of photocells VEDO 180 Couple of photocells VEDO 180 Con Con N L Key selector APRO 0 2 1 2 1 M1 M2 F6 3A F2A STOP P P nc n...

Page 11: ...c n c n o n a n o n a n o n a n o n a n c n c n c n c n c n c n c FCA FCA FCA FCC FCC FCC FCA FCA n c n c n c n c n c M1 M1 M1 M2 M2 3 4 FT3 BSA BSA BSC BSC TX RX 24V Couple of photocells VEDO 180 8 2K 8 2K 8 2K 8 2K Fig E Fig F 11 ...

Page 12: ...ion has been completed carry out a series of tests to make sure that the safety devices warning signals and release mechanisms are all working correctly 8 Write the following information down for the user in the instruction manual for example a the presence of any residual risk factors that have not been protected and factors that could arrive from unforeseen use of the system b The end user must ...

Page 13: ...enabled Connect 8 2K safety edges or an N C contact with 8 2K resistance in series fig E If unused binding post free set dip 2 to ON part 23 fig A Travel direction inversion during closing If unused binding post free set dip 3 to ON part 23 fig A Temporary movement block during the opening stage Travel direction inversion during closing If unused binding post free set dip 4 to ON part 23 fig A See...

Page 14: ...g pause period connect the photoelectric cell projectors so that the minimum amount of power is used If the jumper part 9 di fig A is set to ON this output will be continuously active Status indication automation CLOSED led off during OPENING flashes slowly during CLOSING flashes quickly STOP block remains lit during the RECLOSING PAUSE double flashing with pause Activates for a couple of seconds ...

Page 15: ... seconds and then opens During opening pressing the P Pbutton has no effect During the pause pressing the P Pbutton has no effect During closing upon pressing the P P button the gate stops for a few seconds and then opens During opening pressing the P Pbutton has no effect During the pause upon pressing the P Pbutton the gate closes During closing upon pressing the P P button the gate stops for a ...

Page 16: ... Function excluded There is no slowdown in the last part of travel Power closing is not carried out Only the M1 output is enabled The pedestrian command partially opens and closes motor M1 Function excluded The flashing light operates 5 seconds before any operation After one complete opening the control unit closes automatically after the programmed pause time Second radio channel output If you do...

Page 17: ... and gate delay information It is also possible to input the deceleration times at this point for the final part of the gates movement or you may try the default settings by moving dip 9 to ON after programming DIP9 set to OFF during programming Deceleration times will not be modified DIP9 set to ON only after programming Default deceleration times will be set DIP 9 set to ON during programming wi...

Page 18: ...utomatic reclosing is not being used you may move directly to point 6a Once the desired pause time has elapsed press button P P and motor M2 will begin to close Press P P again when M2 has reached the desired gate delay angle the motor will stop for a second and then begin to close again At this point you must manually insert the DECELERATION start point using P P if DIP 9 is set to ON The motor w...

Page 19: ...to the ECU Release the motors and move the gates to the position almost open Re engage the motors and switch on the power to the installation Hold down the PROG button part 15 fig A for about 3 seconds until led LD1 lights up part 18 fig A The ECU is now in the programming stage Press button P P part 17 fig A the gate with motor M2 should begin to close if it moves in the opening direction instead...

Page 20: ... programming Checks force times and stopping points We advise you to consider inserting deceleration points DIP 9 set to ON to reduce impact against the travel limits so reducing wear and tear on the mechanical parts Repeat programming if you have modified the mechanical travel limits After point 3e the gate with M1 will start to open Press P P when M1 has reached the desired gate delay angle the ...

Page 21: ...ill have to manually using the P P command input all the travel limit information It is also possible to input the deceleration times at this point for the final part of the gate movement or you may try the default settings by moving dip 9 to ON after programming DIP9 set to OFF during programming Deceleration times will not be modified DIP9 set to ON only after programming Default deceleration ti...

Page 22: ...t points 3c 4b and 6b In this case the ECU willAUTOMATICALLY detect all the travel limit information Programming is more precise and quicker thanks to the encoder sensor The deceleration points and times will be inserted automatically To modify them you need only insert the new values during programming DIP9 set to ON This procedure allows you to modify the pause time set during a previous program...

Page 23: ... for all those who have to manage installations on a daily basis and in the future would like to do so by means of a long distance Wi Fi connection MODIFYING AND CONTROLLING SETTINGS USING PRG Link optional This product ismade up of various components that could contain pollutants Dispose of properly Make enquiries concerning the recycling or disposal of the product complying with the local laws i...

Page 24: ...ale dell azienda Dott Cristiano Cardin Amministratore delegato La dichiarazione di conformità CE per i prodotti Cardin è disponibile in lingua originale nel sito www cardin it nella sezione norme e certificazione attraverso il link Les déclarations de conformité CE des produits Cardin sont disponibles dans la langue originale sur le site www cardin it dans la section normes et certificats par le l...

Reviews: