5. Cable Parameters
he most common cable parameters are installed in the device.
1. Basic V/2=100m/µs ø 0.6mm C0.042nF
(default)
2. Default V/2=100 Dia=0,4mm C/km
3. A-02Y/0,5/STIII Zell,PE
4. A-02Y/0,8/STIII Zell,PE
5. A-02YSF/0,5/STIII Foam Skin,PE
6. A-02YSF/0,6/STIII Zell,PE
7. A-2Y/0,35/STIII Zell,PE
8. A-2Y/0,8/STIII Papier,Lagen
9. A-2Y/0,9/STIII Zell,PE
10. A-2YF/0,35/STIII Voll,PE
11. A-2YF/0,4/STIII Voll,PE
12. A-PWE/0,4/STIII Papier,Buendel
13. A-PWE/0,6/STIII Papier,Buendel
14. A-PWE/A-PM/0,4/STIII Papier,Lagen
15. A-PWE/A-PM/0,6/STIII Papier,Lagen
16. A2Y/0,4/STIII Voll,PE
17. A2Y/0,6/STIII Voll,PE Tragseil
The cable parameters are transferred to the KE2500 via the file
CUPARAMS.DAT. To do this, set up a USB connection (see page
20) and then copy the file to the directory KE2500: \ SYS \ KECT.
Create new copper cable parameters:
The
F2 +
key is used to copy a parameter for editing and can then be
edited with
F4 Edit
. By entering only 2 values - such as the cable
diameter ø and the resistance per meter R '- the KE2500 indepen-
.dently calculate the remaining copper cable parameters.
Use the left / right control buttons to scroll through the values. The
selected value is then selected with
SEL
and changed in the context
menu via the numeric keypad.
Make sure that the new settings are saved under a changed label as
the default setting. To change the name go to
Name
and confirm
with
SEL
to get to the context menu for the name change, after the
name change confirm with
SEL
an you will get back to the cable
parameter menu, press F4 Save for conclusion. The new name will
now appear under
Cable Parameters
in the selection menu.
SEL
selects the desired value. This is then marked with a hook at
the right edge of the screen. The
F3 DEL
button can be used to
remove the cables that are installed.
Cable Parameters
Basic V/2=100m/µs ø 0.6mm C0.042nF
Default V/2=100 Dia=0,4mm C/km=
A-02Y/0,5/STIII Zell,PE
A-02Y/0,8/STIII Zell,PE
A-02YSF/0,5/STIII Foam Skin,PE
A-02YSF/0,6/STIII Zell,PE
A-2Y/0,35/STIII Zell,PE
A-2Y/0,8/STIII Papier,Lagen
A-2Y/0,9/STIII Zell,PE
Date / Time
1
2
3
4
5
6
7
8
9
Cable Parameters
test-kabel-06
Date / Time
Name:
Ø
= 0.600 mm
R'
= 0.0636
W
/m
2
k
= 55.600 m/
W
mm
V
= 200.0 m/
µ
s
VF
= 0.66
Save
2
A
= 0.282 mm
2R'
= 0.1272
W
/m
C'
= 0.098 nF/m
V/2
= 100.0 m/
µ
s
Cable Parameters
Cable Parameters
test-kabel-06
Y(ST)Y_4x2x06
Date / Time
Date / Time
Name:
Name:
Ø
= 0.600 mm
Ø
=
mm
0.600
R'
= 0.0636
W
/m
R'
= 0.0636
W
/m
2
k
= 55.600 m/
W
mm
2
k
= 55.600 m/
W
mm
V
= 200.0 m/
µ
s
V
= 200.0 m/
µ
s
VF
= 0.66
VF
= 0.66
Save
Clear
2
A
=
mm
0.282
2
A
= 0.282 mm
2R'
= 0.1272
W
/m
2R'
= 0.1272
W
/m
C'
= 0.098 nF/m
C'
= 0.098 nF/m
V/2
= 100.0 m/
µ
s
V/2
= 100.0 m/
µ
s
Conductor Cross-Section
2
0.282 mm
=
•
*
KURTH ELECTRONIC www.kurthelectronic.de [email protected]
19
Operating Manual
Telco Multimeter
KE2500
1
a=0.0039 /K
T
= 20°C
1
a=0.0039 /K
1
a=0.0039 /K
T
= 20°C
T
= 20°C
Edit
DEL
+
Predefined copper cable types