Product Data 

 

Electrical Data 

 

SST (Transmitter) 

SSR (Receiver) 

Supply voltage 

18 – 30 V dc 

Max. Voltage ripple 

15 % (within supply range) 

Current consumption 

100 mA (RMS)

 

75 mA 

Max. outputs load 

Digital 

100 mA 

Analogue 

Voltage:  Z

load

 

 

1kΩ

 

Current: Z

load

 

 600

 

Reverse polarity protected 

Yes 

Short circuit protected 

Yes 

Inductive load protection 

Yes 

 

Environmental Data 

Light immunity @5º incidence 

> 100.000 lux 

Temperature, operation 

-30 to + 60 ºC 

Sealing class 

 IP 67 

Marking 

 

 

Available Models 

 

Model 

Beam spacing 

Sensing Range 

Transmitter 

SST 02-10-xxx-xxx-05-H-1D1-0.5-J5 

5 mm 

10 m 

SST 02-10-xxx-xxx-10-H-1D1-0.5-J5 

10 mm 

SST 02-10-xxx-xxx-20-H-1D1-0.5-J5 

20 mm 

SST 02-10-xxx-xxx-40-H-1D1-0.5-J5 

40 mm 

Receiver 

SSR 02-10-xxx-xxx-05-H-UUK-ZZW--0.5-J12 

5 mm 

0.5 m – 10 m 

SSR 02-10-xxx-xxx-10-H-UUK-ZZW--0.5-J12 

10 mm 

SSR 02-10-xxx-xxx-20-H-UUK-ZZW--0.5-J12 

20 mm 

SSR 02-10-xxx-xxx-40-H-UUK-ZZW--0.5-J12 

40 mm 

 

Connection

 

 

Wiring Diagrams

 

   

 

                 5 pin, M12                                                                       12 pin, M12 

        

 

 

 

 

 

 

 

 

 

 

SST 5 pole M12 male connector 

 

 

SSR 12 pole M12 male connector 

 

 

Transmitter Model 

Black wire  

connected to ( - ) 

Black wire  

not connected 

Black wire  

connected to ( + ) 

SST 02-10-xxx-xxx-xx-H-1D1-0.5-J5 

not transmitting 

transmitting 

transmitting 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring diagram 

 

UUK-ZZW 

Pin 5 

Pink 

Pin 6 

Yellow 

Pin 7 

Black 

Pin 8 

Green 

Pin 9 

Red 

Pin 10 

Violet 

AC2 - DN2 

Dig. NPN Out 2  Dig. Input 1  Analog Out +  Analog Out - 

Dig. NPN Out 1 

AC2 - DP2 

Dig. PNP Out 2  Dig. Input 1  Analog Out +  Analog Out - 

Dig. PNP Out 1 

ANN - DN4 

Dig. NPN Out 2 

Dig. NPN Out 3  Dig. NPN Out 4  Dig. NPN Out 1 

ANN - DP4 

Dig. PNP Out 2 

Dig. PNP Out 3  Dig. PPN Out 4  Dig. PNP Out 1 

  “ - “ = Not used 

 

Type name: SSR 02-10-xxx-xxx-xx-H-

UUK-ZZW

--0.5-J8.  

The letters 

UUK-ZZW

 determine the output configuration of the SSR 02.

 

 

Output configurations 

 

 

 

 

 

 

 

 

Installation & Adjustments

 

 

Installation

 

The light curtain is configured by the PC program ‘Telco Space Scan Terminal’, described in 

the following pages. Before using it, check the power supply complies with electrical data. 

Mount the transmitter (SST) and receiver (SSR) facing each other and correctly aligned.  

Wire the sensor according to the wiring diagram.  

Notice that the pin 2 on the SSR and the pin 3 on SST (blue wires) must be connected 

together to a common GND ( – ).   

Make sure the SSR output load does not exceed 100 mA. 

Check for correct wiring before turning power on. 

When the power on indicator (green LED) on SSR and SST is on, the system is 

operating. 

The position of the receiver and transmitter must not be changed after power-up. The 

light curtain is only intended for static applications. 

 

SST Test Input                                                                                                                       

The transmitter SST can be externally disabled and enabled via the black control wire for test 

purposes. When the transmitter is disabled the action of the receiver corresponds to breaking 

all beams. 

 

SSR Digital Input 1                                                                                                                         

The digital input can be used to switch between two different output readings on the analogue 

output.  

The time from a transition on the digital input to a transition on the analogue output is 

dependent on the number of beams. 

The maximum transition time can be calculated as 500us + the number of beams multiplied by 

15us. 

Using cross beam scan mode will double the number of beams. 

While communication on the RS485 in ongoing, the transition time will be considerably longer. 

 

Indicators 

SSR 

Red LED 

Status indicator 

SSR 

Yellow LED 

Follows state of Digital Output 1 

SSR & SST 

Green LED 

Power on indicator 

 

Troubleshooting 

Probable Reason 

Corrective Action 

1.

 Symptom: Status indicator (Red LED) on SSR is constant on. 

SST has no power. 

Check supply and supply cable to the SST  

SST & SSR white, grey and blue wires are 

not connected correctly. 

Connect the wires. 

 

2.

 Symptom: Output indicator (Yellow LED) on SSR is flashing. 

Severe electrical interference. 

Separate SSR and SST supply cable from high 

voltage cables. 

Severe ambient light. 

Swap position of SSR and SST. 

Cross talk from another light curtain or 

photo sensor 

Swap position of SSR and SST. 

Cross talk from a nearby HF strip light 

Swap position of SSR and SST or remove the 

strip light. 

 

3.

 Symptom: Digital outputs do not response when IR beams are obstructed. 

One or more beams are blocked or the 

rails are out of sensing range. 

Remove obstruction or reduce the distance 

between the rails. 

The test input on SST is activated 

Remove SST pin 4 (black wire) from ground. 

Outputs are not configured for simple 

detection of obstructions 

If needed factory reset the SSR using the 

System Information page in the PC program 

‘Telco Space Scan Terminal’ 

 

Summary of Contents for Space Scan SS02 Series

Page 1: ...g pages Before using it check the power supply complies with electrical data 1 Mount the transmitter SST and receiver SSR facing each other and correctly aligned 2 Wire the sensor according to the wir...

Page 2: ...o make changes without prior notice Page 2 of 7 tel EN SSR02 and PC connection To setup or adjust a SS02 it is required to use the Telco Space Scan Terminal software together with an RS485 data link 1...

Page 3: ...go The information is stored in a previously saved configuration file in ASCII format Save configuration Saves information about the current configuration of the light curtain Colour Preference It is...

Page 4: ...re the status of the beams are ignored Blanking can either be setup by writing directly which beams to be blanked in the text box Writing 12 16 20 means that all beams starting from beam no 12 and end...

Page 5: ...de Position of the first beam made LBB Last Beam Blocked Position of the last beam blocked LBM Last Beam Made Position of the last beam made MBB Middle Beam Blocked Position of the FBB LBB 2 rounded t...

Page 6: ...aluation of a Boolean expression that here is set up using the two pull down boxes and text input box The first box contains the same list of functions as available under Analogue Output Function plus...

Page 7: ...oes not include the self checking redundant circuitry necessary to allow its use in personnel machine guarding stand alone safety applications April 2019 edition Made in Denmark Telco A S reserves the...

Reviews: