background image

   

 

ICE S 2800 

 

 Rev.001 

 

The  original  version  of  this  manual  was 
written 

in 

Italian 

language. 

The 

Manufacturer  is  not  responsible  for  any 
translation 

errors 

present 

on 

other 

languages versions. 

 
This  manual  has  been  drawn  up  by  the 
manufacturer  in  order  to  provide  all  the 
information  /  instructions  needed  for  proper, 
safe  use  and  maintenance  of  the  air 
conditioner. 
The  manual  is  an  important  part  of  the  air 
conditioner: it must be stored safely and kept 
in  good  condition  throughout  the  working  life 
of 

the 

machine 

and 

protected 

from 

deterioration.  It  must  accompany  the  air 
conditioner if re-installed on a new vehicle or 
sold. 
The  information  contained  in  this  manual  is 
intended  for  air  conditioner  installers  and  all 
those involved in its use and maintenance. 
The manual defines the purpose for which the 
conditioner  has  been  built  and  contains  all 
the  information  required  for  its  safe,  correct 
use. 
Constant  observance  of  the  information  it 
contains  will  ensure  user  safety,  low  running 
costs and a longer air conditioner life. 
To  make  consultation  easy  the  manual  is 
divided  into  sections,  each  of  which  deals 
with  a  specific  topic.  To  find  information 
quickly refer to the table of contents. 
You  are  strongly  advised  to  read  the  entire 
manual  and  the reference  documents: this  is 
the 

best 

way 

to 

ensure 

long-lasting 

performance,  reliability  and  prevention  of 
injury or damage. 
 
The  drawings  included  in  this  manual  are 
provided  for  illustrative  purposes  only. 
Although  the  machine  in  your  possession 
may  differ  in  some  details  from  the 
illustrations  contained  in  this  manual,  the 
safety  and  information  regarding  it  are 
nevertheless guaranteed. 
 
"Graphic  safety  symbols"  are  used  in  this 
document to identify various levels of danger 
or important information: 
 

  Information  to  avoid  a  potentially 

dangerous  situation that  could  cause  serious 
personal injury or possible damage to health. 
 

  Information  to  avoid  a  situation  that 

could potentially cause damage to objects. 
 

  Important  information  for  proper 

execution  of  the  operations  described  or  for 
proper use of the equipment. 
 
 

  Before  carrying  out  any  work  on 

the  air  conditioner,  carefully  consult  this 
manual 

and 

make 

sure 

you 

have 

understood its contents. 

 

 

Before starting work, wear personal 

protective  equipment  (goggles,  gloves, 
dust  masks,  etc.)  appropriate  to  the  type 
of work to be done. 

 

   

The  air  conditioning  unit  must  be 

installed  exclusively  by  qualified  and 
authorized  personnel,  in  accordance  with 
the 

instructions 

provided 

by 

the 

manufacturer. It must be used on vehicles 
or in a stationary installation connected in 
all  cases  to  an  electrical  system  installed 
in  compliance  with  current  regulations 
and  sized  in  relation  to  the  electrical 
power. 
 

 

The  manufacturer  is  not  liable  for 

any damages resulting from improper use 
of the air conditioner. 

 

  It  is  mandatory  to  install  a  double-

pole  thermal  magnetic  circuit  breaker  on 
the  230V  power  supply  line  upstream  of 
the  air  conditioner  to  protect  against 
overcurrents caused by the appliance and 
to  serve  as  a  disconnect  switch  when the 
appliance  is  not  in  use  or  undergoing 
maintenance.  The  specifications  of  the 
switch should be determined in relation to 
the power rating and inrush current of the 
air conditioner. 

 

Summary of Contents for ice S2800

Page 1: ...MANUAL FOR INSTALLATION AND USER MANUAL v 001 May 2021...

Page 2: ...ffer in some details from the illustrations contained in this manual the safety and information regarding it are nevertheless guaranteed Graphic safety symbols are used in this document to identify va...

Page 3: ...Do not insert anything into the air vents of the diffuser or the condenser fan In the event of fire do not open the top cover of the AC unit and only use approved fire extinguishers Do not attempt to...

Page 4: ...rendered null and void in the event of incorrect assembly improper use or modifications made to the machine without our written approval Machine AIR CONDITIONER Model ICE S 2800 Serial n Reference dir...

Page 5: ...minary checks 12 5 3 Useful tips 12 5 4 Installing the batteries in the remote control 13 5 5 Information on using the Remote Control 13 5 6 Remote Control description and functions 13 5 7 Remote Cont...

Page 6: ...r cooling 990 Watt Power consumption for heating 950 Watt Cooling capacity 2500 Watt Heating capacity 2450 Btu h Operating temperature 2 48 C Internal temperature adjustment range 16 31 C Internal fan...

Page 7: ...the symbol on the packaging Stacking more than five packaged air conditioners can damage the conditioners themselves and put personnel at risk of injury 3 2 Weight Weight of ICE S 2800 including packa...

Page 8: ...terior which might obstruct diffuser attachment fig 1 ref 6 or the outflow of cool air from the adjustable vents fig 1 ref 8 The air conditioner may be installed in one of two different ways by using...

Page 9: ...ectrical wires fig 4 ref 2 Fix a reinforcement frame around the opening fig 5 4 2 3 Power lead A 3 core cable with a 2 5 mm cross section live neutral earth must be routed for the power supply of the...

Page 10: ...ing damage to the roof Bring the air conditioner onto the roof fig 7 ref 2 and without scraping it position it over the 360 x 360 mm opening previously lined with sealant Correct alignment of the air...

Page 11: ...multiple fittings The purpose of the fitting is to form a sealed channel to connect the diffuser inlet port to the outlet port on the bottom of the air conditioner Open the two doors on the diffuser...

Page 12: ...air conditioner Subsequently only open doors and windows when necessary 5 2 Preliminary checks Before switching on the air conditioner for the very first time Check that condensate drainage holes are...

Page 13: ...ontrol for some time remove the batteries If the signal transmission sound is no longer audible in the internal unit or the transmission symbol is no longer clearly visible on the display screen the b...

Page 14: ...ting mode 4 Ventilation mode 5 Timer start time only visible if the timer has been activated 6 Timer stop time only visible if the timer has been activated 7 System time 8 Temperature setting 9 Courte...

Page 15: ...ys TEMP and TEMP 4 Press the FAN key several times until you reach your required ventilation setting 5 12 Heating operation mode 1 Press the On Off key 2 Press the MODE key several times until the dis...

Page 16: ...temperature setting 24 C 6 MAINTENANCE 6 1 Cleaning the filters To ensure full efficiency of the air conditioner clean the diffuser filters by washing them with a neutral detergent solution allow them...

Page 17: ...even after the exchangers have been cleaned check the refrigerating gas load 6 4 Opening the external lid The external lid in ABS is attached to the base by 6 re usable rivets To remove them proceed a...

Page 18: ...n of this appliance are recyclable In the event of disposal it is advisable to bring the unit to a specialist workshop or designated waste collection centre Waste materials must not be dispersed into...

Page 19: ...period shall end no later than 14 months 16 months if delivered outside of Europe after ex factory delivery In any case the costs of lubricants and consumables shall be charged Any transport expenses...

Page 20: ...itor C4 Condenser fan capacitor C5 Compressor run capacitor EvGAS 4 way solenoid valve MC Compressor motor VC Condenser fan motor VE Evaporator fan motor CTP condenser temperature probe ETP Evaporator...

Page 21: ...Rev 001 ICE S 2800 21 10 SPARE PARTS LIST...

Page 22: ...ICE S 2800 Rev 001 22...

Page 23: ...ompresor 13 06180 n 1 Scatola condensatore Bo te de condensateur Doos van de condensator Condenser box Kondensatorkasten Caja del condensador 14 06181 n 1 Coperchio del condensatore Couvercle du conde...

Page 24: ...jeta electr nica 74 06239 n 1 Condotto aria adesivo rettangolare per diffusore Conduit d air adh sif rectangulaire pour diffuseur Rechthoekige lijm luchtkanaal voor diffuser Rectangular adhesive air d...

Page 25: ...Rev 001 ICE S 2800 25 Notes...

Page 26: ...ICE S 2800 Rev 001 26 Notes...

Page 27: ...Rev 001 ICE S 2800 27 Notes...

Page 28: ...ICE S 2800 Rev 001 28...

Reviews: