15 

display  will  show  the  camper  indoor 
temperature again. 
 
 

5.9  Setting  system  time  on  remote 

control 

 
After  inserting  the  batteries,  set  the  system 
time on your remote control: 
1)  Press  and  hold  down  the 

SET

  key  on 

your  remote  control  until  the  system time 
digits start flashing 

2)  By  using  the 

+HOUR

  and 

–HOUR

  keys, 

set your system time 

3)  Press the 

SET

 key once again 

 
 

5.10  Automatic operation mode 

 
1)  Press the 

On/Off 

key  

2)  Press the 

MODE

 key repeatedly until the 

display  shows  the 

Automatic 

mode 

symbol

 

 

3)  Set  your  required  temperature  with  the 

keys 

+TEMP

 and 

–TEMP 

 

4)  Press the 

FAN

 key several times until you 

reach your required ventilation setting. 

 
 

5.11  Cold operation mode 
 

1)  Press the 

On/Off 

key 

 

2)  Press the 

MODE 

key repeatedly until the 

display shows the 

COLD 

mode symbol. 

3)  Set  your  required  temperature  with  the 

keys 

+TEMP

 and 

-TEMP

4)  Press the 

FAN

 key several times until you 

reach your required ventilation setting. 

 
 
5.12  Heating operation mode 

 

1)  Press the 

On/Off 

key

 

2)  Press the 

MODE

 key several times until 

the display shows the 

HOT 

mode symbol.

 

3)  Set your required temperature with the 

keys 

+TEMP

 and 

-TEMP

.

 

4)  Press the 

FAN

 key several times until you 

reach your required ventilation setting.

 

 

 If the air conditioner is switched off 

and 

immediately 

re-started 

or 

the 

operating  mode  is  changed,  a  three-

minute  interval  will  elapse  before  the 
compressor resumes operating. 

 

  If  the  air  conditioner  is  turned  off 

during  the  heating  mode,  the  fan  will 
remain  in  operation  for  a  few  minutes  in 
order  to  dissipate  the  heat  accumulated 
inside the air conditioner, before stopping 
automatically. 

 
 

5.13  Timer setting  

 
1)  Press  the 

TIMER

  key  on  the  remote 

control:  the  start  time 

ON

  indicator  is 

activated 

2)  By  using  the 

+HOUR

  and 

–HOUR

  keys, 

set the start time 

3)  Press  the 

TIMER

  key  once  again:  the 

stop time 

OFF

 indicator is activated 

4)  By  using  the 

+HOUR

  and 

–HOUR

  keys, 

set the stop time 

5)  Press the 

TIMER

 key once again 

6)  After  completing  the  setting  operations, 

press the 

SET

 key 

 
To  delete  timer  programming  press  the 

CLEAR

 key 

 

  The  start  and  stop  times  are 

programmable in 10 minutes' steps.

 

 
 

5.14  Operation without remote control 

 

 

 
If the  remote  control  is  lost  or  not  working,  it 
is  still  possible  to  use  the  air  conditioner  by 
delicately  pressing  with  a  sharp  object  the 
small Reset key hidden inside the slot next to 
the display (Fig. 22). 

Summary of Contents for 5400H

Page 1: ...MANUAL FOR INSTALLATION AND USER MANUAL v 004 January 2017...

Page 2: ...ent to identify various levels of danger or important information Information to avoid a potentially dangerous situation that could cause serious personal injury or possible damage to health Informati...

Page 3: ...fire extinguishers Do not attempt to extinguish flames from the air conditioner with water This appliance can be used by children over 8 years of age or persons with reduced physical sensory or mental...

Page 4: ...declaration is rendered null and void in the event of incorrect assembly improper use or modifications made to the machine without our written approval Machine AIR CONDITIONER Model SILENT 5400 H Ser...

Page 5: ...minary checks 12 5 3 Useful tips 12 5 4 Installing batteries in the Remote Control 13 5 5 Information on Remote Control use 13 5 6 Remote control key definitions functions 13 5 7 Remote control displa...

Page 6: ...rature adjustment range 16 31 C Internal fan speed number 3 Maximum internal air flow 300 m h Type and quantity of coolant gas R 407c 430 g Waterproof rating IP X4 Generator required 2200 W Diffuser d...

Page 7: ...ners can damage the conditioners themselves and put personnel at risk of injury 3 2 Weight Weight of SILENT 5400 H including packaging 39 kg 3 3 Handling Always observe safety and accident prevention...

Page 8: ...g ventilation port This solution is practical as long as the port size is 395 x 395 mm fig 2 Proceed by removing the screws that fix the port to the roof and then removing the port itself Scrape off a...

Page 9: ...al cable must be suitably protected in order to ensure its integrity and insulation in all conditions of use of the vehicle 4 3 Positioning the air conditioner Before installation check that the cylin...

Page 10: ...rt the connection outlet at the base of the air conditioner use the four supplied 12 mm long self tapping screws to fix it Align with the rectangular hole of the fan Fig 9 The arrow in figure 9 indica...

Page 11: ...is shown in Fig 13 4 4 Connecting the power lead Connect the previously prepared cable of the unit to the 230V AC power supply terminal Fig 14 Please note that the colour of the wires according to th...

Page 12: ...ontrol signals electronic board which receives the signals from the receiver and transforms them into commands for the various electrical components of the air conditioner The SILENT 5400H provides co...

Page 13: ...d the internal unit Do not drop or throw the remote control Do not expose the remote control to direct sunlight or leave it near heating systems or other sources of heat If you do not intend to use th...

Page 14: ...te control IR receiver When the red Power light Fig 20 ref A is lit on the display the air conditioner is powered off 230 Vac line power When the green Run light Fig 20 ref B is lit the air conditione...

Page 15: ...equired temperature with the keys TEMP and TEMP 4 Press the FAN key several times until you reach your required ventilation setting If the air conditioner is switched off and immediately re started or...

Page 16: ...ly Check that the system is electrically live by connecting another household appliance or using a voltmeter 2 Air outflow is insufficient Check that the directional vents are open enough Check that t...

Page 17: ...hicle Remove any traces of oxidation from metallic parts and protect the zone with a suitable paint Check that wiring insulation is in good condition and eliminate any traces of oxidation or moisture...

Page 18: ...all end no later than 14 months 16 months if delivered outside of Europe after ex factory delivery In any case the costs of lubricants and consumables shall be charged Any transport expenses shall hav...

Page 19: ...ondenser fan capacitor C5 Compressor run capacitor EvGAS 4 way solenoid valve MC Compressor motor VC Condenser fan motor VE Evaporator fan motor CTP condenser temperature probe ETP Evaporator temperat...

Page 20: ...20 10 SPARE PARTS LIST...

Page 21: ...21...

Page 22: ...apa del condensador 16 06523 n 1 Gruppo condensante Groupe de condensation Condensatie unit Condenser unit Kondensatoreinheit Unidad de condensacion 17 06542 n 1 Ventilatore Condensante Ventilateur de...

Page 23: ...a Diffuseur de l air Diffuser voor de lucht Air diffuser Diffusor f r Luft Difusor de aire 79 03512 n 2 Aletta per diffusore Ailette pour le diffuseur de l air Vin voor de lucht diffuser Fin for air d...

Page 24: ...24...

Reviews: