Telair 5400H Manual For Installation And User Manual Download Page 11

 

   

       

 

 

11 

 

 
Cut  the  two  sides  of  the  connector  duct  (fig. 
11)  so  that  they  do  not  protrude  from  the 
tunnel edge. 

 
Fold the two long sides of the connector duct 
(fig.  12)  so  that  they  are  horizontally  in 
contact  with  the  horizontal  surface  of  the 
tunnel.  
The resulting connection is shown in Fig.13. 
 

 

 
 

4.4  Connecting the power lead 

 
Connect the previously prepared cable of the 
unit  to  the  230V  AC  power  supply  terminal 
(Fig. 14). 
Please  note  that  the  colour  of  the  wires 
according to their use is: 

blue wire: neutral 

brown wire: phase 
yellow-green wire: earth 

 

 

 

 
Check that the power lead is not excessively 
long as it could obstruct the intake grilles. 
 
 

4.5  Installing the diffuser 

 

 

 
Remove  the  two  adjustable  airflow  director 
fins from the diffuser (fig. 15) 
 

 

 

Summary of Contents for 5400H

Page 1: ...MANUAL FOR INSTALLATION AND USER MANUAL v 004 January 2017...

Page 2: ...ent to identify various levels of danger or important information Information to avoid a potentially dangerous situation that could cause serious personal injury or possible damage to health Informati...

Page 3: ...fire extinguishers Do not attempt to extinguish flames from the air conditioner with water This appliance can be used by children over 8 years of age or persons with reduced physical sensory or mental...

Page 4: ...declaration is rendered null and void in the event of incorrect assembly improper use or modifications made to the machine without our written approval Machine AIR CONDITIONER Model SILENT 5400 H Ser...

Page 5: ...minary checks 12 5 3 Useful tips 12 5 4 Installing batteries in the Remote Control 13 5 5 Information on Remote Control use 13 5 6 Remote control key definitions functions 13 5 7 Remote control displa...

Page 6: ...rature adjustment range 16 31 C Internal fan speed number 3 Maximum internal air flow 300 m h Type and quantity of coolant gas R 407c 430 g Waterproof rating IP X4 Generator required 2200 W Diffuser d...

Page 7: ...ners can damage the conditioners themselves and put personnel at risk of injury 3 2 Weight Weight of SILENT 5400 H including packaging 39 kg 3 3 Handling Always observe safety and accident prevention...

Page 8: ...g ventilation port This solution is practical as long as the port size is 395 x 395 mm fig 2 Proceed by removing the screws that fix the port to the roof and then removing the port itself Scrape off a...

Page 9: ...al cable must be suitably protected in order to ensure its integrity and insulation in all conditions of use of the vehicle 4 3 Positioning the air conditioner Before installation check that the cylin...

Page 10: ...rt the connection outlet at the base of the air conditioner use the four supplied 12 mm long self tapping screws to fix it Align with the rectangular hole of the fan Fig 9 The arrow in figure 9 indica...

Page 11: ...is shown in Fig 13 4 4 Connecting the power lead Connect the previously prepared cable of the unit to the 230V AC power supply terminal Fig 14 Please note that the colour of the wires according to th...

Page 12: ...ontrol signals electronic board which receives the signals from the receiver and transforms them into commands for the various electrical components of the air conditioner The SILENT 5400H provides co...

Page 13: ...d the internal unit Do not drop or throw the remote control Do not expose the remote control to direct sunlight or leave it near heating systems or other sources of heat If you do not intend to use th...

Page 14: ...te control IR receiver When the red Power light Fig 20 ref A is lit on the display the air conditioner is powered off 230 Vac line power When the green Run light Fig 20 ref B is lit the air conditione...

Page 15: ...equired temperature with the keys TEMP and TEMP 4 Press the FAN key several times until you reach your required ventilation setting If the air conditioner is switched off and immediately re started or...

Page 16: ...ly Check that the system is electrically live by connecting another household appliance or using a voltmeter 2 Air outflow is insufficient Check that the directional vents are open enough Check that t...

Page 17: ...hicle Remove any traces of oxidation from metallic parts and protect the zone with a suitable paint Check that wiring insulation is in good condition and eliminate any traces of oxidation or moisture...

Page 18: ...all end no later than 14 months 16 months if delivered outside of Europe after ex factory delivery In any case the costs of lubricants and consumables shall be charged Any transport expenses shall hav...

Page 19: ...ondenser fan capacitor C5 Compressor run capacitor EvGAS 4 way solenoid valve MC Compressor motor VC Condenser fan motor VE Evaporator fan motor CTP condenser temperature probe ETP Evaporator temperat...

Page 20: ...20 10 SPARE PARTS LIST...

Page 21: ...21...

Page 22: ...apa del condensador 16 06523 n 1 Gruppo condensante Groupe de condensation Condensatie unit Condenser unit Kondensatoreinheit Unidad de condensacion 17 06542 n 1 Ventilatore Condensante Ventilateur de...

Page 23: ...a Diffuseur de l air Diffuser voor de lucht Air diffuser Diffusor f r Luft Difusor de aire 79 03512 n 2 Aletta per diffusore Ailette pour le diffuseur de l air Vin voor de lucht diffuser Fin for air d...

Page 24: ...24...

Reviews: