Telair 5400H Manual For Installation And User Manual Download Page 12

   

 

 

12 

Plug  the  flat  cable  coming  from  the  diffuser 
display into the connector coming from the air 
conditioner electronic board (Fig. 16). 
If  in  the  flat  cable  coming  from  the  air 
conditioner  Pcb  there  is  also  a  2-pin 
connector, it remains unused. 
Fix the diffuser with the 4 self-tapping screws 
L. 25 mm (Fig. 17). 
 

 

 
Then re-insert the two airflow director fins. 

 
 

5  INSTRUCTIONS FOR USE 

 

5.1  Introduction 

 

  The  power  supply  voltage  must 

never be less than 205V AC, with a stable 
frequency of 50Hz. 

 

 

Outside  the  specified  operating 

temperature range, the efficiency of the air 
conditioner is reduced considerably. 

 

The 

SILENT  5400H 

air  conditioner  consists 

of nine main parts: 
 

 

compressor

, which circulates the coolant 

gas through the system. 

 

condenser

,  which  cools  the  coolant  by 

changing  it  from  a  gaseous  to  a  liquid 
state. 

 

evaporator

, which, cooled by the change 

of  state  of  the  coolant,  cools  the  air 
passing through it. 

 

two  fans

,  which  move  the  air  so  that  it 

passes  through  the  condenser  and 
evaporator 

 

solenoid  valve

,  which  switches  gas 

circulation  and  so  provides  a  cooling  or 
heating function 

 

remote  control 

to  program  the  desired 

function 

 

receiver, 

situated  in  the  diffuser,  which 

receives the remote control signals 

 

electronic  board, 

which  receives  the 

signals  from  the  receiver

 

and  transforms 

them  into  commands  for  the  various 
electrical 

components 

of 

the 

air 

conditioner. 

 
The 

SILENT  5400H

  provides  cold  air  during 

the summer months and hot air in winter. 
If  the  vehicle  has  been  left  in  the  sun  for 
some  time  it  is  good  practice  to  open 
windows  and  doors  before  starting  the 
conditioner  so  as  to  release  the  build  up  of 
heat  in  the  interior;  once  indoor  temperature 
matches  outdoor  temperature  close  the 
windows  and  doors  and  start  the  air 
conditioner.  Subsequently,  only  open  doors 
and windows when necessary. 
 
 

5.2  Preliminary checks 

 
Before switching on the air conditioner for the 
very first time: 

  Check  that  condensate  drainage  holes 

are unobstructed. 

  Check that the power supply  voltage and 

frequency 

match 

the 

required 

specifications. 

  Check that air flow through relative ducts 

and  vents  is  unobstructed.  To  ensure 
maximum efficiency always keep external 
ventilation grilles clear. 

 

  When  the  equipment  is  started  for 

the  first  time  with  the  remote  control,  the 
fan and compressor will also start within a 
few  seconds.  After  a  power-off,  upon  the 
next  power-on  the  compressor  will  only 
start  after  at  least  3  minutes  from  the 
power-off. 

 
 

5.3  Useful tips 

 

 

  Enhance  the  thermal  insulation  of  the 

camper  by  eliminating  any  fissures  and 
covering  glass  surfaces  with  heat-
reflecting curtains. 

Summary of Contents for 5400H

Page 1: ...MANUAL FOR INSTALLATION AND USER MANUAL v 004 January 2017...

Page 2: ...ent to identify various levels of danger or important information Information to avoid a potentially dangerous situation that could cause serious personal injury or possible damage to health Informati...

Page 3: ...fire extinguishers Do not attempt to extinguish flames from the air conditioner with water This appliance can be used by children over 8 years of age or persons with reduced physical sensory or mental...

Page 4: ...declaration is rendered null and void in the event of incorrect assembly improper use or modifications made to the machine without our written approval Machine AIR CONDITIONER Model SILENT 5400 H Ser...

Page 5: ...minary checks 12 5 3 Useful tips 12 5 4 Installing batteries in the Remote Control 13 5 5 Information on Remote Control use 13 5 6 Remote control key definitions functions 13 5 7 Remote control displa...

Page 6: ...rature adjustment range 16 31 C Internal fan speed number 3 Maximum internal air flow 300 m h Type and quantity of coolant gas R 407c 430 g Waterproof rating IP X4 Generator required 2200 W Diffuser d...

Page 7: ...ners can damage the conditioners themselves and put personnel at risk of injury 3 2 Weight Weight of SILENT 5400 H including packaging 39 kg 3 3 Handling Always observe safety and accident prevention...

Page 8: ...g ventilation port This solution is practical as long as the port size is 395 x 395 mm fig 2 Proceed by removing the screws that fix the port to the roof and then removing the port itself Scrape off a...

Page 9: ...al cable must be suitably protected in order to ensure its integrity and insulation in all conditions of use of the vehicle 4 3 Positioning the air conditioner Before installation check that the cylin...

Page 10: ...rt the connection outlet at the base of the air conditioner use the four supplied 12 mm long self tapping screws to fix it Align with the rectangular hole of the fan Fig 9 The arrow in figure 9 indica...

Page 11: ...is shown in Fig 13 4 4 Connecting the power lead Connect the previously prepared cable of the unit to the 230V AC power supply terminal Fig 14 Please note that the colour of the wires according to th...

Page 12: ...ontrol signals electronic board which receives the signals from the receiver and transforms them into commands for the various electrical components of the air conditioner The SILENT 5400H provides co...

Page 13: ...d the internal unit Do not drop or throw the remote control Do not expose the remote control to direct sunlight or leave it near heating systems or other sources of heat If you do not intend to use th...

Page 14: ...te control IR receiver When the red Power light Fig 20 ref A is lit on the display the air conditioner is powered off 230 Vac line power When the green Run light Fig 20 ref B is lit the air conditione...

Page 15: ...equired temperature with the keys TEMP and TEMP 4 Press the FAN key several times until you reach your required ventilation setting If the air conditioner is switched off and immediately re started or...

Page 16: ...ly Check that the system is electrically live by connecting another household appliance or using a voltmeter 2 Air outflow is insufficient Check that the directional vents are open enough Check that t...

Page 17: ...hicle Remove any traces of oxidation from metallic parts and protect the zone with a suitable paint Check that wiring insulation is in good condition and eliminate any traces of oxidation or moisture...

Page 18: ...all end no later than 14 months 16 months if delivered outside of Europe after ex factory delivery In any case the costs of lubricants and consumables shall be charged Any transport expenses shall hav...

Page 19: ...ondenser fan capacitor C5 Compressor run capacitor EvGAS 4 way solenoid valve MC Compressor motor VC Condenser fan motor VE Evaporator fan motor CTP condenser temperature probe ETP Evaporator temperat...

Page 20: ...20 10 SPARE PARTS LIST...

Page 21: ...21...

Page 22: ...apa del condensador 16 06523 n 1 Gruppo condensante Groupe de condensation Condensatie unit Condenser unit Kondensatoreinheit Unidad de condensacion 17 06542 n 1 Ventilatore Condensante Ventilateur de...

Page 23: ...a Diffuseur de l air Diffuser voor de lucht Air diffuser Diffusor f r Luft Difusor de aire 79 03512 n 2 Aletta per diffusore Ailette pour le diffuseur de l air Vin voor de lucht diffuser Fin for air d...

Page 24: ...24...