background image

 

17

 

6.0  LIMITATION OF WARRANTY AND LIABILITY 

 

Seller warrants that this product, under normal use and service as described in the operator’s manual shall be free 
from defects in workmanship and material for a period of twelve (12) months, or the length of time specified in the 
operator’s manual, from the date of shipment to the customer. This limited warranty is subject to the following 
exclusion :- 

 

a. 

Batteries and certain other components when indicated in specifications are warranted for a 
period of 90 days from the date of shipment to the customer. 

b. 

With respect to any repair services rendered, Seller warrants that the parts repaired or replaced 
will be free from defects in workmanship and material, under normal use, for a period of 90 days 
from the date of shipment to the customer 

c. 

Seller does not provide any warranty on finished goods manufactured by others. Only the 
original manufacturer’s warranty applies. 

d. 

Unless specifically authorised in a separate writing by Seller, Seller makes no warranty with 
respect to, and shall have no liability in connection with, any goods  which are incorporated into 
other products or equipment by the Buyer. All goods returned under warranty shall be at the 
Buyer’s risk of loss, Seller’s factory prepaid, and will be returned at Seller’s risk of loss, Buyer’s 
factory prepaid. 

 
The foregoing is IN LIEU OF all other warranties and is subject to the conditions and LIMITATIONS stated herein. 
NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR 
MERCHANTABILITY IS MADE. 
 
THE EXCLUSIVE REMEDY OF THE USER OR PURCHASER, AND THE LIMIT OF LIABILITY OF SELLER FOR 
ANY AND ALL LOSSES, INJURIES, OR DAMAGES IN CONNECTION WITH THIS PRODUCT ( INCLUDING 
CLAIMS BASED ON CONTRACT NEGLIGENCE, STRICT LIABILITY, OTHER TORT, OR OTHERWISE ) SHALL 
BE THE RETURN OF THE PRODUCT TO THE FACTORY OR DESIGNATED LOCATION AND THE REFUND OF 
THE PURCHASE PRICE, OR, AT THE OPTION OF THE SELLER, THE REPAIR OR REPLACEMENT OF THE 
PRODUCT. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL 
DAMAGES.SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING, REASSEMBLY OR 
REINSTALLATION COSTS OR CHARGES. NO ACTION, REGARDLESS OF FORM, MAY BE BROUGHT AGAINST 
THE SELLER MORE THAN ONE YEAR AFTER THE CAUSE OF ACTION HAS ACCRUED. 
 
The purchaser and all users are deemed to have accepted the terms of this LIMITATION OF WARRANTY AND 
LIABILITY, which contains the complete and exclusive limited warranty of Seller. This LIMITATION OF WARRANTY 
AND LIABILITY may not be amended or modified nor may any of its terms be waived except by a  writing signed by 
an authorised representative of the Seller. 

 

7.0  Contact us :-

 

 
 
 

For further information on our range of airflow alarms and controls 
please contact us at :- 
 
 
 

 

TEMPERATURE ELECTRONICS Ltd 

388 / 400  MANCHESTER ROAD 
ROCHDALE 
LANCS , ENGLAND 
OL11  4NW

 

Tel

 : +44 1706 633438    

Fax

 :  +44 1706 524609 

 
Web site:   

www.tel-uk.com

Summary of Contents for AFA1000 / 1 - Mk2

Page 1: ...Digital display 3 Relay inputs 3 Relay outputs Com port Used for alarm indication and monitoring on Fume Cupboards Model AFA1000 2 Mk2 Digital display 3 Relay inputs 3 Relay outputs 3 Pushbuttons Com...

Page 2: ...Passwords in the Main Menu or alternatively use a Laptop connected to the Com port and the Upload Download software provided Velocity Bar Graph or Alarm Time Line Velocity display m sec or fpm Control...

Page 3: ...R2 R3 SENSOR SOCKET 0 10V ECON OUTPUT 15V DC POWER SUPPLY INPUT 0 10V AUX OUTPUT s w Sash Proximity switch OUTPUT RELAYS COMMS PORT RELAY INPUTS INPUT 1 INPUT 2 INPUT 3 Bn Bk Bl Sash Micro switch REF...

Page 4: ...representing events that have occurred during the past hour The alternative to the event time line is a dynamic bar graph representing the face velocity The display shows a Horn icon with line through...

Page 5: ...the calibration and configuration menu or to select options or values External Connections the alarm unit will have the following connection points Input 1 volt free relay input configurable for norma...

Page 6: ...a Fan stop start button for the fume cupboard extract fan or as Night Set back Override Pushbutton 2 This button can be configured to act as a Lights ON OFF or UV Lights On OFF for the fume cupboard o...

Page 7: ...e configuration of the alarm NOTE If you enter the Calibration or Configure Menu by accident press the buttons at the same time to escape back to the Main Menu The menus and sub menus are in plain lan...

Page 8: ...ime the Low air alarm resets automatically High airflow If configured High Air toggles on off with display Audible alarm sounds can be muted via Enter pushbutton Audible alarm Mute When the audible al...

Page 9: ...ctivated Night Set Back Icon is displayed Red LED on Flashing Reduced Low air alarm if configured Audible alarm muted Mute Icon shown on display External alarm When input configured as External alarm...

Page 10: ...isables Night setback operation in Override On condition Note In the On condition the unit ignores any Night Set back input signals and remains in this condition until Off is selected Pushbutton 2 Pum...

Page 11: ...setup press ENTER to continue and in the Main Menu use the buttons on the alarm facia select SETUP and then press the ENTER button 7 In the Setup Menu select CALIBRATION and press the ENTER button 8...

Page 12: ...individual lowest point on the grid For most fume cupboards this low point is on the bottom row in the centre and is a convenient position to measure and for future reference when checking the alarm...

Page 13: ...ensor Hole for Vent Tube SM6 Sensor Dimensions Rear view SM6 Sensor Panel Cutout Dimensions Front view NOT TO SCALE 2 x Holes for self tapping fixing screw 4mm Fixing Hole provided on SM6 sensor Panel...

Page 14: ...ng position using a flexible tube With a single skin side wall it is possible to fix the sensor on the outside of the fume cupboard and connect directly to the inner chamber in the ideal position This...

Page 15: ...SM6 Airflow Sensor R1 R2 R3 SENSOR SOCKET 0 10V ECON OUTPUT 15V DC POWER SUPPLY INPUT 0 10V AUX OUTPUT s w Sash Proximity switch OUTPUT RELAYS COMMS PORT RELAY INPUTS INPUT 1 INPUT 2 INPUT 3 Bn Bk Bl...

Page 16: ...oximity switch Optional SM6 Airflow Sensor R1 R2 R3 SENSOR SOCKET 0 10V ECON OUTPUT 15V DC POWER SUPPLY INPUT 0 10V AUX OUTPUT s w Sash Proximity switch OUTPUT RELAYS COMMS PORT RELAY INPUTS INPUT 1 I...

Page 17: ...F all other warranties and is subject to the conditions and LIMITATIONS stated herein NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE THE EXCLUSIVE RE...

Reviews: