background image

 

 

 

Configuration: 

Set HDCP Compliance status for every input, and manage EDID. See the screenshot 

below: 

 

Network: 

Inquire  and  configure  network  settings  including  MAC  address,  IP  address,  subnet  mask, 

and Gateway 

 

Note: 

Log in as user access main interface only. 

 

GUI Update 

GUI  for  MUH44TPR2-N  supports  online  update  in 

http://192.168.0.178:100

.  Type  the  username  and 

password  (the  same  as  the  GUI  log-in  settings,  modified  password  will  be  available  only  after 
rebooting) to log in the configuration interface. After that, click 

Administration

 at the source menu to 

get to 

Upload Program

 as shown below: 

 

Select the desired update file and press Apply, it will start upgrading then. 

 

 

Summary of Contents for TEK-MUHD44TP 79055

Page 1: ...used for service Specifications are subject to change without notice Please ask your local dealer for detailed information Copyright 2018 TEKVOX Inc No part of the contents of this book may be transmi...

Page 2: ...30 F To avoid any damage by over heat please provide adequate ventilation to radiate the heat when operating the device The device should be turned off when in wet or humid areas The AC power supply...

Page 3: ...eration 9 Usage of IR Remote 9 6 2 2 IR Operations 10 Force Carrier 10 Control Far end Device locally 10 Control Local Device Remotely 11 RS232 CONTROL 12 Connection with RS232 Communication Port 12 C...

Page 4: ......

Page 5: ...DVI 1 0 Powerful EDID and HDCP management HDBaseT Lite outputs to transmit HDMI IR RS 232 up to 200 1080 or 130 at 4K over a single Cat 6A cable Output PoC provides power for all the receivers connec...

Page 6: ...annel No 3 Operation Press buttons in this order 1 AV 3 ALL outputs button To transfer one input to all outputs Example To transfer both AV and IR signals from input channel No 1 to all output channel...

Page 7: ...seT receivers and all IR signals can be switched synchronously with the AV signal or separately switched OUTPUTS a IR IN Connect with IR receiver fixed IR input for the output cannot be switched separ...

Page 8: ...ate red when powered on DC 24V Connect with DC 24V power adaptor GROUND Connect to grounding make the unit ground well 4 4 HDBaseT Twisted Pair Cable Connection Always use a minimum of 30 feet Cat 5E...

Page 9: ...TEK MUHD44TP 4x4 HDBaseT Matrix TEKVOX INC 5 www tekvox com 830 460 9099 5 System Diagram...

Page 10: ...R Example Convert input 1 to all outputs Note Indicators of the pressed buttons will blink green for three times if the conversion is done then it will be off If the conversion failed they will be off...

Page 11: ...1 2 to switch among the 5 embedded EDID data Then press ENTER to confirm invoking Format Press and hold EDID for 3 seconds INPUTS OUTPUTS 1 2 ENTER Operations Invoke embedded EDID data for one input...

Page 12: ...with HDCP Y means the input signal is with HDCP N means not Check if the output is with HDCP Y means the output signal is with HDCP N means not Check the output resolution Use the UP and DOWN directio...

Page 13: ...ontrol local input output device remotely 3 Control the MUH44TPR2 N locally remotely Usage of IR Remote Standby button press it to enter exit standby mode Input channels range from 1 4 buttons 5 8 are...

Page 14: ...with IR carrier to the IR IN port of MUH44TPR2 N users can control far end output displayer via its IR remote from local In that case the IR signal is transferred via twisted pair Only the correspondi...

Page 15: ...ix See as below IR Matrix The IR signal is sent by corresponding IR remote then it is transferred to HDBaseT receiver then to corresponding zone of the matrix through the twisted pair finally it is tr...

Page 16: ...rt Connect a control device to the 9 pin RS232 port of the switcher users are able to control the switcher far end device See the figure below Control the switcher 3rd party Device through 9 pin femal...

Page 17: ...vice 3rd party device and connect PC to the corresponding same zone as controlled device receiver see below Control 3rd party device from remote Installation uninstallation of RS232 Control Software I...

Page 18: ...gnals from the input channel x to all output channels X To All X 01 04 All Transfer all input signals to the corresponding output channels respectively like 1 1 2 2 All Through All Switch off all the...

Page 19: ...audio output of port x X 1 2 3 4 enable this port X 5 enable all the 4 ports DigitAudio ON with x DigitAudioOFF x Disable HDMI audio output of port x X 1 2 3 4 disable this port X 5 disable all the 4...

Page 20: ...rations will be canceled after 10 seconds Please cut off all connections of HDBaseT ports Please send the EDID file EDID x y Set the EDID data of input port x to built in EDID No y y 1 5 correspond to...

Page 21: ...ect Y Y Y Y 9972 Check the connection status of the outputs Out 01 02 03 04 Connect Y Y Y Y 9973 Check the HDCP status of the inputs In 1 2 3 4 HDCP N N N N 9974 Check the HDCP status of the outputs O...

Page 22: ...r to the network port you must use a crossover network cable or network switch Set its IP address of the PC to the same IP VLAN as the default IP is address or the unit 192 168 0 178 6 6 Connection an...

Page 23: ...er username and the right password Here is a brief introduction to the interfaces Main Interface shown after logging in provide intuitive I O connection switching See the screenshot below The button m...

Page 24: ...main interface only GUI Update GUI for MUH44TPR2 N supports online update in http 192 168 0 178 100 Type the username and password the same as the GUI log in settings modified password will be availab...

Page 25: ...via USB When you need to upgrade it download the latest upgrade file and use the update EXE software Copy the EXE software to the PC and double chick the program to run the program Connect a Micro USB...

Page 26: ...P Supports HDCP 2 2 auto and manual HDCP management Audio General Output Signal Stereo audio Digital audio Output Connector 4 3p captive screw connectors 4 Coax RCA Stereo Output 200 ohm Coax Output S...

Page 27: ...ectrical or mechanical abuse abnormal operating conditions or non TEKVOX authorized modifications to said product If it has been determined product is defective please call TEKVOX and ask for an Appli...

Reviews: