www.tekvox.com
1201-MV
79033-MV User Manual
7. RS232 Control
The RS232 port of switcher has two control methods.
1.
Local control
: Connect the RS232 port to a control device (e.g. PC) to control the switcher with
RS232 commands.
2.
Display device control
: The RS232 port is used with the RS232 port of a far-end HDBaseT receiver
to control the display device (e.g. Projector).
RS232 Commands:
The command listed below are used to control the switcher. An RS232 control software needs to be
installed on the control PC to send RS232 commands.
After installing the RS232 control software, set the parameters of COM number, baud rate, data bit,
stop bit, and parity bit correctly, then commands can be sent to the 1201-MV.
Baud rate
: 9600
Data bit
: 8
Stop bit
: 1
Parity bit
: None
Notes:
⚫
All commands must be terminated
with “<CR>”
⚫
All feedbacks are terminated with
“<CR>
<LF
>”
⚫
In the commands, “[”and “]”
characters MUST be typed in order to function correctly
⚫
Type commands carefully, as they are case-sensitive
⚫
These same commands are used with TCP/IP port 4001