www.tekvox.com
1201-MV
79033-MV User Manual
5.3 Display Setting Tab
Automatic CEC and RS232 Control:
Enable or disable Automatic Display Control Mode. In Automatic
Display Control Mode, the unit will automatically perform the operations listed below:
System On:
When the unit detects a source signal (5V), or receives the
“Wake Up” command, it will automatically
perform the following operations:
1.
Send the
Display On
CEC or RS232 command to the display
2.
RS232 Only. Send the
Display On
RS232 command to the display, then wait for the specified
Delay
Time
(default: 3/5 S), then send the
Display Input Select
RS232 command to the display
System Off:
When the unit does not detect a source signal and the No Signal Timeout (default: 10 minutes) is on,
or the unit receives a
“Power Off” command, it will automatically perform the following steps:
1.
Send a
Display Off
CEC or RS232 command to the display
2.
RS232 Only. Send
Display Off
RS232 command to the display device. This command is sent once
by default, or it can be set to send twice via settings.
3.
After executing the
“
System Off
”
command, the
“
System On
”
can again be triggered.
No Signal Timeout:
The system will enter Standby Mode, and the display device will automatically
shut down, when no source signal is detected within this time interval.
Baud Rate:
Set the baud rate for the display device (9600, 19200, 38400, 57600, or 115200)
Command Format:
The default command format is ASCII; select
“
Hex
”
to enter commands as
hexadecimal strings.
Command Ending:
Select whether to terminate commands with NULL, CR, LF, or CR+LF
Display On:
Enter
the “
Display On
”
RS232 command for turning on the display, then click
“
Save
”
.