Instructions

020-2664-00
TLA7012 Portable Logic Analyzer
Rackmount Kit

071-1750-00

*P071175000*

071175000

Warning

The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.

www.tektronix.com

Summary of Contents for TLA7012

Page 1: ...071 1750 00 P071175000 071175000 Warning The servicing instructions are for use by qualified personnel only To avoid personal injury do not perform any servicing unless you are qualified to do so Refe...

Page 2: ...and pending Information in this publication supercedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tek...

Page 3: ...falling onto the operator two or more installers should install the instrument into the rack cabinet After completing the installation procedure the installers should verify that the instrument and ra...

Page 4: ...Service Safety Summary 2 TLA7012 Portable Logic Analyzer Rackmount Kit Instructions...

Page 5: ...quires you to remove the right side panel of the instrument rack you intend to use You must have access to the right side of your instrument to connect the logic analyzer probes when the instrument is...

Page 6: ...Kit Description 4 TLA7012 Portable Logic Analyzer Rackmount Kit Instructions Figure 1 Completed rackmount installation...

Page 7: ...ANUAL INSTRUCTIONS TLA7012 1 1 ea 436 0426 00 CHASSIS ASSY TLA7012 RACKMOUNT INCLUDES 6 32 AND 10 32 SCREWS 2 1 ea 407 5122 00 BRACKET LOCKING 3 2 ea 386 7459 00 PANEL COSMETIC 4 1 ea 351 1119 00 GUID...

Page 8: ...Kit Description 6 TLA7012 Portable Logic Analyzer Rackmount Kit Instructions 1 2 3 4 5 6 7 8 Figure 2 Rackmount kit parts...

Page 9: ...ents mounted using methods other than those described in these instructions may not meet their warranted requirements See Specifications in the user or service manual that applies to your instrument m...

Page 10: ...in which the rack adapted instrument is mounted must provide the following clearance requirements H A minimum of 14 0 inches 355 6 mm of vertical space H A minimum width of 17 717 inches 450 mm betwe...

Page 11: ...ption TLA7012 Portable Logic Analyzer Rackmount Kit Instructions 9 541 mm 21 300 in 412 02 mm 16 230 in 480 00 mm 18 897 in 352 1 mm 13 862 in 352 1 mm 13 862 in Figure 4 Instrument with rack adapter...

Page 12: ...Kit Description 10 TLA7012 Portable Logic Analyzer Rackmount Kit Instructions...

Page 13: ...ment cabinet All tools are standard tools that are readily available Table 2 Tools required for rackmount installation Item no Name Description 1 Screwdriver handle magnetic Accepts 1 4 inch hexagonal...

Page 14: ...lly extended Do not leave the instrument extended when finished accessing the rear panel Assemble Shelf Begin the installation procedure by attaching the brackets to the track assembly 1 Remove the mo...

Page 15: ...track onto the shelf assembly applying 28 inch lbs of torque You must move the rail within the track to gain access to the rearward mounting hole Refer to Figure 6 to help you attach the tracks to th...

Page 16: ...to the instrument rack 1 Remove the right side panel of the instrument rack 2 Select two 0 5 inch spaced holes that have at least 14 inches of clearance above on all four rails of the rack See Figure...

Page 17: ...with the rear flanges inside of rails use the mounting method B outlined in Figure 8 This mounting method assumes untapped holes Mounting Method A Mounting Method B Left rear rail Use two flat head s...

Page 18: ...ing shelf installation Equipment Required One screwdriver handle Item 1 one number two Pozidriv tip Item 2 and one torque driver Item 5 NOTE The rack hardware kit contains hardware for mounting the in...

Page 19: ...on each side of the shelf front 4 Install two 8 32 screws through the shelf tracks to the rear brackets Attach the screws with the 8 32 lock nuts included in the kit 5 Tighten all of the screws and c...

Page 20: ...e 11 Right side brackets Left side brackets Flip the feet down Figure 11 Location of screws for bracket mounting 3 Attach the right and left side brackets to the bottom of the instrument using the scr...

Page 21: ...to make it lighter Always reinstall the mechanical safety stop after you push the instrument back into the rack WARNING To prevent the rackmounted instrument from tipping forward onto the operator ins...

Page 22: ...right side screw out The screws are stored on the rear of the shelf See Figure 12 Leave this screw out Three 6 32 screws Instrument brackets Shelf Extra hardware provided on rear of shelf assembly Fi...

Page 23: ...helf with the fourth 6 32 screw See Figure 13 Safety stop Fourth 6 32 screw Optional storage location for handle Two 10 32 screws Figure 13 Mount the safety stop to the shelf 7 Secure the shelf to the...

Page 24: ...ine the best route for the probes to your DUT This may include a front or rear exit through the instrument rack or a combination of the two 3 Push the module end of the probe one at a time through the...

Page 25: ...ic Analyzer Rackmount Kit Instructions 23 Route the probes where you need them Probes out back Probes out front Figure 14 Routing the probes 6 Repeat steps 2 through 5 for the remaining probes 7 Conne...