background image

Speci

fi

cations

Table 8: TLA5000 trigger system (cont.)

Characteristic

Description

By event

Storage can be turned on or off; only the current sample can be stored. The event storage
control overrides any global storage commands.

Block storage

When enabled, 31 samples are stored before and after the valid sample.
Not allowed when glitch storage or setup and hold violation is enabled.

Glitch violation storage

The acquisition memory can be enabled to store glitch violation information with each data
sample when asynchronous clocking is used. The probe data storage size is reduced by one
half (the other half holds the violation information). The fastest asynchronous clocking rate
is reduced to 4 ns.

Setup and hold violation storage

The acquisition memory can be enabled to store setup and hold violation information with each
data sample when synchronous clocking is used. The probe data storage size is reduced by
one half (the other half holds the violation information). The maximum clock rate in this mode is
235 MHz.

1

Each use of External Signal In, glitch detector, setup and hold violation detector, or transition detector requires a trade-off of one word recognizer resource.

2

Any glitch is subject to pulse width variation of up to the channel-to-channel skew speci

fi

 0.25 ns.

3

Any setup value is subject to variation of up to the channel skew speci

fi

cation. Any hold value is subject to variation of the channel skew speci

fi

cations.

Table 9: TLA5000 MagniVu feature

Characteristic

Description

MagniVu memory depth

16,000 samples per channel

MagniVu sampling period

Data is asynchronously sampled and stored every 125 ps in a separate
high resolution memory. The storage speed may be changed (by software)
to 250 ps, 500 ps, or 1000 ps so that MagniVu memory covers more time
at a lower resolution.

Table 10: TLA5000 Data Placement

Characteristic

Description

System time zero placement error

(Typical)

±4 ns + backplane 10 MHz skew
All stored data is referenced to this point.

Data correlation error

(Typical)

±200 ps + system time zero placement error

TLA5000 Series Product Speci

fi

cations & Performance Veri

fi

cation

13

Summary of Contents for TLA500 Series

Page 1: ...ment applies to TLA System Software Version 5 1SP1 and above Warning These servicing instructions are for use by qualified personnel only To avoid personal injury do not perform any servicing unless y...

Page 2: ...is publication supersedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc MagniVu and iView a...

Page 3: ...duties taxes and any other charges for products returned to any other locations This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintena...

Page 4: ......

Page 5: ...rformance Verification Procedures 21 Summary Verification 21 Certification 21 Test Equipment 22 Functional Verification 23 Performance Verification 25 Checking the 10 MHz System Clock CLK10 26 Thresho...

Page 6: ...e 3 Setting trigger parameters 28 Figure 4 Set the trigger states 32 Figure 5 Threshold Accuracy test fixture 34 Figure 6 Solder square pins to the SMA connector 35 Figure 7 Solder the SMA connectors...

Page 7: ...e 12 TLA5000B internal controller 14 Table 13 TLA5000 internal controller 15 Table 14 TLA5000 display system 15 Table 15 TLA5000 front panel interface 16 Table 16 TLA5000 rear panel interface 16 Table...

Page 8: ...that the product is properly grounded Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and markings on the product Consult the product manual for further ratings informa...

Page 9: ...ult in damage to this product or other property Symbols and Terms on the Product These terms may appear on the product DANGER indicates an injury hazard immediately accessible as you read the marking...

Page 10: ...ndering first aid and resuscitation is present Disconnect Power To avoid electric shock switch off the instrument power then disconnect the power cord from the mains power Use Care When Servicing With...

Page 11: ...e materials are reused or recycled appropriately This symbol indicates that this product complies with the European Union s requirements according to Directive 2002 96 EC on waste electrical and elect...

Page 12: ...Environmental Considerations viii TLA5000 Series Product Specifications Performance Verification...

Page 13: ...to follow all warnings cautions and notes in this manual Related Documentation The following table lists related documentation available for your logic analyzer The documentation is available on the...

Page 14: ...ic analyzer product Optional Service Manuals Self service documentation for modules and mainframes TLA Application Software Release Notes Software description compatibility impact of changes contact i...

Page 15: ...EC 61000 4 6 2003 Conducted RF immunity IEC 61000 4 11 2004 Voltage dips and interruptions immunity EN 61000 3 2 2000 AC power line harmonic emissions EN 61000 3 3 1995 Voltage changes fluctuations an...

Page 16: ...re rated Pollution Degree 1 No pollution or only dry nonconductive pollution occurs Products in this category are generally encapsulated hermetically sealed or located in clean rooms Pollution Degree...

Page 17: ...source of low voltage installation Measurement Category III For measurements performed in the building installation Measurement Category II For measurements performed on circuits directly connected to...

Page 18: ...0 C and 30 C For optimum performance using an external oscilloscope please consult the documentation for any external oscilloscopes used with your Tektronix logic analyzer to determine the warm up per...

Page 19: ...pF CLK Qual channels Probe input capacitance Typical P6419 0 7 pF Minimum slew rate Typical 0 2 V ns Maximum operating signal 6 0 Vp p P6410 P6417 P6418 P6419 250 mV or 25 of signal swing minimum req...

Page 20: ...destinations 5 SMPL represents the time from the event to the next valid data sample at the probe tip input In the Normal Internal clock mode this represents the delta time to the next sample clock In...

Page 21: ...ground 0 7 V sinking 10 mA Signal 1 2 Signal 3 4 Output bandwidth 2 50 MHz square wave minimum 10 MHz square wave minimum Active period Outputs signals during valid acquisition periods resets signals...

Page 22: ...y depth TLA520XB 2 M or optionally 8 M or 32 M samples 1 Acquisition memory depth TLA520X 512 K or optionally 2 or 8 M samples 1 1 PowerFlex options Table 6 Reference clock CLK10 Characteristic Descri...

Page 23: ...nimum recognizable word 2 across all channels Channel to channel skew sample uncertainty Example for a 2 ns sample period and a P6419 or P6434 Probe 400 ps 2 ns 2 4 ns Synchronous clocking Product Clo...

Page 24: ...CK1 to from CK0 to from D3 7 0 D2 7 0 D1 7 0 D0 7 0 C1 7 0 C0 7 0 E1 7 0 TLA5204 only E0 7 0 TLA5204 only Q2 TLA5204 only Q3 TLA5204 only Q0 Q1 Any individual channel may be demultiplexed with its pa...

Page 25: ...rd recognizers 13 word recognizers 10 word recognizers 7 word recognizers 4 word recognizers 0 range recognizers 1 range recognizer 2 range recognizers 3 range recognizers 4 range recognizers Range re...

Page 26: ...rolled by the main acquisition trigger machine MagniVu trigger position The MagniV trigger position is programmable within 2 ns boundaries and separate from the main acquisition memory trigger positio...

Page 27: ...information The maximum clock rate in this mode is 235 MHz 1 Each use of External Signal In glitch detector setup and hold violation detector or transition detector requires a trade off of one word re...

Page 28: ...NVRAM Battery life is 10 years Table 12 TLA5000B internal controller Characteristic Description Operating system Microsoft Windows Microprocessor Intel Celeron 2 93 GHz Style 184 pin DDR2 SDRAM DIMM...

Page 29: ...tegrated Device Electronics hard disk drive residing on an EIDE interface Continually subject to change due to the fast moving PC component environment Storage capacities valid at product introduction...

Page 30: ...4 K 16 8 M 256 64 K 16 8 M 256 64 K 16 8 M 256 64 K 16 8 M 256 64K 60 75 85 60 75 85 60 75 85 60 75 85 60 75 85 60 75 Classification Thin Film Transistor TFT 10 4 inch active matrix color LCD display...

Page 31: ...Yes On Standby Switch and Indicator Front Panel On Standby switch with indicator The power cord provides main power disconnect Table 18 TLA5000 cooling Characteristic Description Cooling System Forced...

Page 32: ...Specifications Figure 1 Dimensions of the TLA5000 series logic analyzer 18 TLA5000 Series Product Specifications Performance Verification...

Page 33: ...list of supported external oscilloscopes visit our Web site at www tektronix com TDS1000 TDS2000 2 3 TDS1000B and TDS2000B Series 3 4 TDS3000 and TDS3000B Series TDS3GM GPIB RS 232 communication modu...

Page 34: ...e physically located close together so that the iView cable can span both instruments Removing the sleeving from the iView cable assembly increases the spacing distance available between the external...

Page 35: ...ed in the Specifications chapter of this manual The performance verification procedures certify the accuracy of an instrument and provide a traceability path to national standards As you complete the...

Page 36: ...Hz Agilent 33131A 4 Digital timing generator 1 235 MHz 0 1 accuracy DC output 0 5 V 0 1 accuracy Tektronix DTG5274 5 DC voltage source see footnote 0 5 V 0 1 accuracy Tektronix PS281 6 Digital multime...

Page 37: ...wer on and fan operation Power up diagnostics Extended diagnostics TLA5000 Series logic analyzers CheckIt Utilities diagnostics Power on and Fan Operation Complete the following steps to check the pow...

Page 38: ...All tests that displayed an Unknown status will change to a Pass or Fail status depending on the outcome of the tests 6 Scroll through the tests and verify that all tests pass CheckIt Utilities CheckI...

Page 39: ...1 Verified by the 10 MHz system clock test Threshold accuracy 1 Verified by the threshold accuracy test Certified by running the certification procedure Setup and hold window size data and qualifiers...

Page 40: ...NC connector on the instrument 3 Select System Configuration from the System menu 4 In the System Configuration dialog box select 10 MHz Clock from the list of routable signals in the External Signal...

Page 41: ...imeter with the required accuracy to verify the voltage output levels specified in the procedure TLA5000 Setup To set up the logic analyzer for this test you must define the characteristics of the cha...

Page 42: ...Create a trigger program that triggers the logic analyzer when it doesn t see all highs or all lows a Click the If Then button b Set the channel definition to match the figure below Figure 3 Setting...

Page 43: ...and then record the voltage 5 Set the voltage source to 4 12 V 6 Start the logic analyzer and verify that it does not trigger 7 Decrease the voltage in 10 mV steps waiting at least 3 seconds between...

Page 44: ...ttern representing half the period of CH1 for example 001100110011 binary starting with 00 5 Connect the setup and hold test fixtures to the DTG channels that you have set up Connect 50 SMA terminatio...

Page 45: ...threshold voltage levels to one half the resulting termination voltage which should be about 620 mV not 1 25 V 7 Create a new group right click in the Group Name column 8 Select Add Group from the pop...

Page 46: ...Performance Verification Procedures Figure 4 Set the trigger states 32 TLA5000 Series Product Specifications Performance Verification...

Page 47: ...ncreasing the clock delay until the waveform window displays data that was not acquired correctly Record this delay 3 Add 1 00 ns to the delay value that you recorded in step 2 and increase the DTG cl...

Page 48: ...ription Example part number Square pin strip 0 100 x 0 100 2 x 8 contacts or two 1 x 8 contacts SAMTEC part number TSW 102 06 G S Wire 20 gauge Soldering iron and solder 50 W Build Procedure Use the f...

Page 49: ...pin strip 0 100 x 0 100 2 x 2 contacts or two 1 x 2 contacts SAMTEC part number TSW 102 06 G S SMA termination 50 2 GHz bandwidth Johnson part number 142 0801 866 SMA adapter Male to male Johnson par...

Page 50: ...nnectors together See Figure 7 Figure 7 Solder the SMA connectors together 7 Solder the ground conductors of the SMA connectors together 8 Attach the termination and coupler to the fixture Figure 8 Co...

Page 51: ...umber Verification performed by Verification date Test Data Characteristic Specification Tolerance Incoming data Outgoing data Clock frequency 10 MHz 1 kHz 9 9990 MHz 10 0010 MHz 4 V 100 mV 3 900 V to...

Reviews: