Operating
Instructions—
PS 503A
NOTE
Supply
is
connected for 20
to 40 V output.
Fig. 1-4.
Monitor and load connections.
NOTE
Supply
is connected
for
0
to 40 V output.
Fig.
1-6.
Reverse current shunt (Rs) with active load.
ting
a shunt resistor (Rs) as shown in Fig.1-6 provides an
external,
reverse-current
path
to
the power supply
sources or delivers current
only.
Over-voltage
The
PS
503A is protected from
over-voltage conditions
by an
over-voltage protection
circuit that shuts down the
power
supply
when the voltage rises to about 26 V dc.
NOTE
The point
at which the overvoltage protection blows
the fuse
may be changed for specific applications by
changing
the Zener
diode.
OPERATION
The
following
steps demonstrate
the use of the
PS
503A controls and connectors.
1.
Install
the PS 503A into (preferably) the
high-power
compartment of
the power module.
2.
Press
the OUT button to apply power to the
PS
503A.
Observe that the+and
- VOLTS indicator lights
come on
(the lights will be very dim at low voltages).
Single
Supply Operation
(±20 V Maximum)
1.
Set
the + and
— VOLTS controls for approximately
2
V.
NOTE
Supply
is connected for 0
to 40 V output.
2. Turn the
CURRENT LIMIT controls fully ccw (to
protect the ammeter).
Connect an ammeter between the
common terminal
and
the +
or — terminal and adjust the
appropriate
CURRENT LIMIT control for the maximum
desired
current
output.
Fig.
1-5. Ground loop created by
grounded remote lead.
1-4
REV.
A MAR 1977
Summary of Contents for PS 503A
Page 1: ...Tektronix COMMITTED TO EXCELLENCE PS 503A DUAL POWER SUPPLY INSTRUCTION MANUAL...
Page 4: ...Fig 1 1 PS 503A Dual Power Supply plug in module PS 503A...
Page 36: ...Options PS 503A OPTIONS No options are available at this time...
Page 41: ...I8S4 OX R V P FEB IR77 PS 5O3A...
Page 42: ...is 4 qx FL V P FEB IR77 Poweb Supply J bm bowo t above...
Page 45: ...TO...
Page 46: ...1834 04...
Page 47: ...PARTIAL POWER SUPPLY...
Page 52: ...REV A DEC 1975 21...
Page 53: ......