Designing an Interface Between a P6434 Probe and a Target System
16
P6434 Probe Instructions
You can contact AMP for more detailed information on the Mictor connectors.
For the address, refer to the
Replaceable Parts
section on page 47.
You can purchase latch housing mechanisms to use with Mictor connectors. The
latch housing surrounds the Mictor connector in your target system and provides
positive retention of the P6434 probe.
Figure 14 shows the dimensions of the optional latch housings.
31.50 mm
(1.240 in)
12.19 mm
(.480 in)
4.95 mm
(.195 in)
1.27 mm
(.050 in)
28.20 mm
(1.110 in)
25.63 mm
(1.009 in)
7.11 mm
(.280 in)
1.52 mm
(.060 in)
1.40 mm
(.055 in)
5.08 mm
(.200 in)
.51 mm
(.020 in)
2.64 mm
(.104 in)
9.90 mm
(.390 in)
3.63 mm (.143 in)
3.55 mm (.140 in)
1.42 mm (.056 in)
25.40 mm
(1.000 in)
Straddle mount
Figure 14: Latch housing dimensions
NOTE
. Refer to the
Replaceable Parts List
section under
Standard Accessories
on
page 48 for information on ordering surface-mounted or straddle-mounted latch
housings.