background image

80A09 26 GHz ESD Protection Device Instructions

Environmental Compliance

Product end-of-life

handling

Observe the following guidelines when recycling an instrument or component:

Equipment recycling.

Production of this equipment required the extraction and

use of natural resources. The equipment may contain substances that could be
harmful to the environment or human health if improperly handled at the product’s
end of life. To avoid release of such substances into the environment and to
reduce the use of natural resources, we encourage you to recycle this product in
an appropriate system that will ensure that most of the materials are reused or
recycled appropriately.

This symbol indicates that this product complies with the applicable European
Union requirements according to Directives 2002/96/EC and 2006/66/EC
on waste electrical and electronic equipment (WEEE) and batteries. For
information about recycling options, check the Support/Service section of the
Tektronix Web site (www.tektronix.com).

Restriction of hazardous

substances

This product is classi

fi

ed as an industrial monitoring and control instrument

accessory, and is not required to comply with the substance restrictions of the
recast RoHS Directive 2011/65/EU until July 22, 2017.

Contacting Tektronix

Tektronix, Inc.
14150 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA

For product information, sales, service, and technical support:

In North America, call 1-800-833-9200.
Worldwide, visit www.tektronix.com to

fi

nd contacts in your area.

80A09 Instructions

5

Summary of Contents for 80A09

Page 1: ... following guidelines to prevent ESD when using the 80A09 or anytime that you are connecting signals or handling the 80A09 or the 80E04 Electrical Sampling Module Always wear a grounded antistatic wrist strap when handling or connecting the 80A09 to the 80E04 module when connecting cables to the 80A09 or when handling or installing sampling modules in the mainframe instrument Wear anti static clot...

Page 2: ...5 in lb 2 Connect the cable from the DUT to the 80A09 Make sure to discharge the cable center and shield to ground before connecting to the 80A09 Use a torque wrench to tighten the connector to 7 5 in lb CAUTION To prevent damaging the 80A09 80E04 module connectors do not put excess pull or lateral movement on the cable attached to the 80A09 80E04 assembly Verify that 80A09 is functional Use the f...

Page 3: ...test limits as specified Always disable the SMU output before connecting or disconnecting the SMU supply from the test setup Set the SMU at zero volts before enabling the output Procedure CAUTION Follow ESD handling guidlelines when connecting cables to the 80A09 See page 1 Best practices to prevent ESD 1 If connected remove the cable from the 80A09 2 Remove the 80A09 from the 80E04 module input C...

Page 4: ...utput 2 0 VDC Verify that the measured current is less than 100 μA 8 Set the SMU to source 65 mA with the overvoltage limit set to 3 5 V Verify that the measured voltage is 3 42 VDC 9 Set the SMU to sink 65 mA with the overvoltage limit set to 3 5 V Verify that the measured voltage is 3 42 VDC 10 Set the SMU output to zero volts disable the SMU output and disconnect the SMA to BNC adapter from the...

Page 5: ...ropriately This symbol indicates that this product complies with the applicable European Union requirements according to Directives 2002 96 EC and 2006 66 EC on waste electrical and electronic equipment WEEE and batteries For information about recycling options check the Support Service section of the Tektronix Web site www tektronix com Restriction of hazardous substances This product is classifi...

Reviews: