![Tektronix 485 Instruction Manual Download Page 38](http://html1.mh-extra.com/html/tektronix/485/485_instruction-manual_1078906038.webp)
Maintenance—4 8 5 /R 4 8 5 Service
F.) A t TP1958 H.V. Current Sens during sampling period
with short on —2950 supply.
G.) A t TP 1926. Inverter Current Sens during sampling period
with all supplies normal.
H.) At TP 1926. Inverter Current Sens during sampling period
with short on +15 supply.
0 V
.5 V /D IV
20 psec/DIV
I.) A t TP1926. Inverter Current Sens during normal opera
tion.
J J
I
.5 V /D IV
20 psec/DIV
►
0 V
J.l At TP1919. Mono Ramp during normal operation.
5 V /D IV
20 psec/DIV
0 V
K.) At collector of Q1900 during normal operation.
50 m V /D IV
20 psec/DIV
L.) A t TP +59.4. Ripple on +59.4 supply during normal
operation (AC coupled).
M.) X10 Probe at Anode of CR1660 Normal operation with
intensity off.
Fig. 4-2. Power Supply Waveforms cont.