Calibration— Type 323
14. Calibration shield. Tektronix calibration fixture 067-
0571-00.
15. Adapter. Adapts GR874 connector to BNC male con
nector. Tektronix Part No. 017-0063-00.
16. Termination. Impedance, 50 ohms; accuracy, ± 3 % ,
connectors, BNC. Tektronix Part No. 011-0049-00.
17. 10X attenuator.
Impedance, 50 ohms; accuracy,
± 3 % ; connectors, BNC. Tektronix Part No. 011-0059-00.
18. Input RC normalizer. Time constant, 1 megohm X
47 pF; attenuation, 2 X ; connectors, BNC. Tektronix cali
bration fixture 067-0541-00.
19. 10X probe for Type 323. Tektronix P6049 Probe rec
ommended (supplied accessory).
20. BNC post jack. Tektronix Part No. 012-0092-00.
21. 10X probe for test oscilloscope. Tektronix P6006
Probe recommended.
22. BNC T connector. Tektronix Part No. 103-0030-00.
23. Patch cord. Length, six inches; connectors, banana
plug-jack and BNC male. Tektronix Part No. 012-0089-00
(supplied accessory).
Adjustment Tools
24. Screwdriver. Three-inch shaft, 3/ 32-inch bit for slotted
screws. Tektronix Part No. 003-0192-00.
25. Low-capacitance screwdriver. 1 ’/ 2-inch shaft. Tektronix
Part No. 003-0000-00.
SHORT-FORM CALIBRATION PROCEDURE
This short-form calibration procedure is provided to aid
in the calibration of the Type 323. It may be used as a
calibration guide by the experienced calibrator, or it may
be reproduced and used as a permanent record of cali
bration. Since the step numbers and titles used here cor
respond to those used in the complete procedure, this pro
cedure also serves as an index to locate a step in the com
plete Calibration Procedure. Performance requirements listed
here correspond to those given in Section 1 of this manual.
Type 323, Serial No. ______________________
Calibration D a t e ____________________________
Calibrated by ___ .__ _________________________
□
1. Adjust Charging Current (R644)
Page 6-6
54 millivolts, ± millivolts across R615 at FULL CHG.
Check for about 20 millivolts across R615 at TRICKLE
CHG.
|~1
2. Adjust High-Voltage Supply and Check
Page 6-7
Regulation (R513)
—1900 volts, ± 3 8 volts. Must maintain this toler
ance over DC power input range.
r~|
3. Adjust Intensity Limit (R583)
Page 6-7
1.00 volt, ±0 .0 5 volt at point K on Power Regu
lator board.
0
4. Adjust - f 5-Volt Power Supply (CAL
Page 6-8
OUT Voltage) (R552)
Adjust for +0.500 volt, ± 2 .5 millivolts, at CAL
OUT jack with Q9 removed. Check for +5.0 volts,
±0.1 volt, output from supply.
1 I
5. Adjust —5-Volt Power Supply (R566)
Page 6-8
—5 Volts, ±0.1 volt.
n
6. Check + 14-Volt and + 175-Volt
Page 6-8
Power Supplies
+ 14-Volt Supply, ± 2 .8 volts
+ 100-Volt Supply, ± 5 Volts
+ 175-Volt Supply, + 1 4 or
—7
volts.
0
7. Check Low-Voltage Power Supply
Page 6-8
Ripple
Power supply
Maximum ripple over
DC power input range
-5 -V o lt
10 millivolts
+5-V olt
10 millivolts
+ 1 4-Volt
150 millivolts
+ 100-Volt
150 millivolts
+ 175-Volt
500 millivolts
0
8. Check Low-Voltage Power-Supply
Page 6-8
Regulation
Power supply
Maximum output change
of supply (regulation) over
DC power input range
-5 -V o lt
±0 .0 3 volt
+5-V olf
±0.025 volt
+ 14-Volt
± 2 .8 volts
+ 100-Volt
± 5 .0 volts
+ 175-Volt
± 1 4 volts
0
9. Check Low Batteries Indicator
Page 6-9
LOW BATT light flashes with DC input voltage
of 6.25 volts, ±0.31 volt.
□ 10. Adjust Variable Volts/Division
Page 6-9
Balance (R40)
Less than one division vertical trace shift as the
VARIABLE VOLTS/DIV control is rotated through
out its range.
0 11. Adjust Vertical X 10 Balance (R39)
Page 6-9
Less than 1.5 division vertical trace shift as the
X 1 0 VERT GAIN switch is pulled out.
0 12. Adjust Deflection Plate DC level (R91,
Page 6-9
R93)
Voltage range at the collectors of Q163 and Q173
as the vertical POSITION control is rotated through
out its range centered about + 5 0 volts.
6-2
®
Summary of Contents for 323
Page 4: ...Type 323 Fig 1 1 Type 323 Oscilloscope ...
Page 14: ...Operating Instructions Type 323 2 2 Fig 2 1 External controls connectors and indicators ...
Page 39: ...Circuit Description Type 323 3 4 Fig 3 3 Paraphase Am plifier simplified ...
Page 51: ...Circuit Description Type 323 3 16 Fig 3 8 Blocking Oscillator simplified ...
Page 71: ...Maintenance Type 323 4 15 Fig 4 13 Transistor data ...
Page 147: ...T Y P E 3 2 3 O S C I L L O S C O P E B L O C K D IA G R A M MRI4 i ...
Page 157: ...BL OCK DIAGRAM ...
Page 158: ......
Page 161: ...A TYPE 323 OSCILLOSCOPE ...
Page 162: ...1 TYPE 323 OSCILLOSCOPE ...
Page 163: ...FIG 2 CABINET ...
Page 164: ...OPTIONAL ACCESSORIES 016 0119 00 1 POWER PACK 016 0112 00 1 COVER protective oscilloscope ...