Technology Solutions
Instruction Manual
Tek-Wave 4300C
www.tek-trol.com
10
•
Indirect echo will be affected by multiple echoes.
•
Multiple echoes may have a larger signal threshold than real echoes because multiple echoes can
be concentrated through the top. Therefore, it cannot be installed in the center position.
Fig 11: Installation at Round Tank
•
Height requirement of connecting pipe: the antenna must extend at least 3/8” (10mm) into the
tank.
Fig 12: Installation with Height Requirement
3⁄
4”
(10
mm
)