Commissioning and Monitoring 

3.1

 

Required Equipment 

The following equipment is required for commissioning and monitoring the Kona Micro 
Outdoor Gateway. 

1.

 

A laptop running Windows XP/Vista/7.  

2.

 

A Cat5 or better Ethernet cable. 

3.2

 

Procedure 

Once the DC power and GPS and LoRa RF antenna connections are in place the Kona Micro 
Outdoor Gateway may be commissioned. 

1.

 

Connect an Ethernet cable between the Host PC and the bulkhead copper  Ethernet 
connector (RJ45). For a PoE powered installation, a PoE power injector may be required.  

2.

 

Apply  DC power to the Kona Micro Outdoor  Gateway. The initial current draw is 
expected to be greater than 0.1A. If there is no current, the polarity of the DC power 
cable connection may be reversed or the power source may not be configured properly. 

3.

 

The Kona Micro Outdoor Gateway supports DHCP; from the Gateway MAC ID label on 
the enclosure, determine the IP address using your local DHCP tools. 

4.

 

Install the Tektelic Kona Factory Test Tool on a PC and follow the operating instructions 
as detailed in the reference document T0004142_GUI_Instructions. 

 

Summary of Contents for Kona Micro Gateway

Page 1: ...ment is subject to change without notice The material herein is solely for information purposes and does not represent a commitment by TEKTELIC or its representatives TEKTELIC has prepared the information contained in this document solely for use by its employees agents and customers Dissemination of this information and or concepts to other parties is prohibited without the prior written consent ...

Page 2: ...rison First release 0 3 Feb 01 2018 Draft S Morrison Added language translation 0 31 Feb 13 2018 Draft T Danshin Updated Table 1 and Table 4 to only reference North American models 0 32 Feb 13 2018 Draft T Danshin Updated product descriptions in Table 1 and 4 0 33 Feb 14 2018 Approved T Danshin Updated MPE information 0 34 Feb 14 2018 Approved T Danshin Updated Radio Compliance Statements ...

Page 3: ...Installation 13 2 6 Direct DC Power Cable Installation 14 2 7 RF Cable Installation 15 2 8 Copper Ethernet Cable Installation 15 3 Commissioning and Monitoring 16 3 1 Required Equipment 16 3 2 Procedure 16 4 Radio Compliance Statements 17 5 Description du produit 18 5 1 aperçu 18 5 2 Interfaces physiques 19 5 3 Spécifications 21 6 Installation 23 6 1 Précautions de sécurité 23 6 2 Déballage et ins...

Page 4: ...34 TEKTELIC Communications Inc Confidential Page 4 of 32 6 7 Installation du câble RF 29 6 8 Installation du câble Ethernet en cuivre 29 7 Mise en service et surveillance 30 7 1 Équipement requis 30 7 2 Procédure 30 8 déclarations de conformité radio 31 ...

Page 5: ... 3G 4G wireless Table 1 presents the currently available Kona Micro Outdoor Gateway models for the North American market Table 1 Kona Micro Outdoor Gateway Models Product Code Description RF Region T0004937 LORA GATEWAY MODULE KONA MICRO OUTDOOR NA FDD LTE MODEM NA T0005129 LORA GATEWAY MODULE KONA MICRO OUTDOOR NA FDD LTE MODEM GEOLOCATION CAPABLE NA T0005247 LORA GATEWAY MODULE KONA MICRO OUTDOO...

Page 6: ... 34 TEKTELIC Communications Inc Confidential Page 6 of 32 Figure 1 Kona Micro Outdoor Gateway Common Dimensions 1 2 Physical Interfaces Figure 2 illustrates the bulkhead layout for the Kona Micro Outdoor Gateway All models share the same bulkhead layout ...

Page 7: ...t all other connectors must be terminated with mating connectors or covered with the supplied protective cap when not in use in order to be water tight Connector types and their mating connectors are listed in Table 2 Table 2 Kona Micro Outdoor Gateway Interface Connector Types Interface Connector Type Mating Connector LoRa Antenna Ports N Type female Industry standard N Type male DC Power 2 pin C...

Page 8: ...re listed in Table 3 Table 3 Kona Micro Outdoor Gateway Specifications Attribute Specification Dimensions 222 2mm 8 7 wide x 101mm 4 0 deep x 287 3mm 11 3 tall Weight 5 1 kg 11 3 lbs Operating Temperature 40 C to 60 C 40 F to 140 F at sea level Including solar loading Relative Humidity 10 to 100 Operating Altitude 60 m to 4 000 m 197 ft to 13 123 ft Power Input Direct DC 48 VDC nominal 37 to 57 VD...

Page 9: ...s properly terminated prior to the connection of any other interface The Kona Micro Outdoor Gateway contains primary lightning surge suppression on the Direct DC power port the Copper Ethernet port and the LoRa RF antenna port The primary lightning protectors have the ability to bridge the interface to chassis isolation boundary during over voltages Ensure that the Protective Earth Ground connecti...

Page 10: ... the shipping carton and report any significant damage to TEKTELIC 2 Unpacking should be conducted in a clean and dry location when possible 3 Do not discard the shipping box or foam inserts as they will be required if a unit is returned for repair or re configuration 2 3 Required Equipment for Installation The following tools are required to install the Kona Micro Outdoor Gateway module 1 A 6 poi...

Page 11: ...cations The mounting bracket is a single part that bolts to the back surface of the Gateway using supplied hardware four M6x1 0 14 mm bolts with flat and star lock washers as illustrated in Figure 4 The Gateway module must be oriented with the connector bulkhead facing down towards earth Mounting screw location Mounting screw location Mounting screw location Mounting screw location ...

Page 12: ...edure is as follows 1 Bolt the wall mounting bracket to the Gateway module using the supplied bolts and washers 2 Install 2 site supplied M8 bolts into the wall at 139 7 mm 5 5 center spacing leaving the bold heads protruding with a 2mm gap from the wall surface 3 Hang the Kona Micro Outdoor Gateway with bracket from the two bolts by inserting the keyhole slots at the top of the bracket onto the 2...

Page 13: ... Outdoor Gateway grounding system shall follow local and national electrical codes The Protective Earth Ground conductor terminated at the double hole lug point is mandatory and must be the first connection made to the Kona Micro Outdoor Gateway during installation Proper routing and termination of this cable is key to robust lightning withstand performance in high susceptibility installations eve...

Page 14: ...ad The direct DC power input is isolated from chassis earth with the exception of the primary surge suppressors One lead of the DC power feed is normally earth referenced external to the Kona Micro Outdoor Gateway usually at the power source by convention The DC power cable shall be rated for outdoor application according to local and national electrical codes The CPC direct DC connector shall be ...

Page 15: ...01 Follow the taping procedures outlined by the supplier of this tape system Note that the 3G 4G modem antenna is internal to the Kona Micro Outdoor Gateway 2 8 Copper Ethernet Cable Installation The Kona Micro Outdoor Gateway Ethernet port may be used on a temporary basis for commissioning and maintenance or may be permanently connected for backhaul When the port is not in use the weatherproof pr...

Page 16: ...t cable between the Host PC and the bulkhead copper Ethernet connector RJ45 For a PoE powered installation a PoE power injector may be required 2 Apply DC power to the Kona Micro Outdoor Gateway The initial current draw is expected to be greater than 0 1A If there is no current the polarity of the DC power cable connection may be reversed or the power source may not be configured properly 3 The Ko...

Page 17: ...dio TV technician for help To comply with FCC IC RF exposure limits for general population uncontrolled exposure the antennas used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmitter This product must be installed by professional trained RF technicians...

Page 18: ...et cuivre ou 3G 4G sans fil Le tableau 4 présente les modèles Kona Micro Outdoor Gateway actuellement disponibles pour le marché nord américain Table 4 Modèles de Kona Micro Outdoor Code produit La description Région RF T0004937 LORA GATEWAY MODULE KONA MICRO OUTDOOR NA FDD LTE MODEM NA T0005129 LORA GATEWAY MODULE KONA MICRO OUTDOOR NA FDD LTE MODEM GEOLOCATION CAPABLE NA T0005247 LORA GATEWAY MO...

Page 19: ... Communications Inc Confidential Page 19 of 32 Figure 7 Kona Micro Outdoor Gateway Dimensions communes 5 2 Interfaces physiques Figure 8 illustre la disposition de la cloison de la Kona Micro Outdoor Gateway Tous les modèles partagent la même disposition de cloison ...

Page 20: ...tre terminés avec des connecteurs correspondants ou recouverts avec le capuchon de protection fourni lorsqu ils ne sont pas utilisés pour être étanches à l eau Les types de connecteurs et leurs connecteurs correspondants sont répertoriés dans Table 5 Table 5 Kona Micro Outdoor Gateway Types de connecteurs d interface Interface Type de connecteur Connecteur compatible Ports d antenne LoRa N Type fe...

Page 21: ...s de Kona Micro Outdoor Gateway sont répertoriées dans Table 6 Table 6 Kona Micro Outdoor Gateway Spécifications Attribute Spécifications Dimensions 222 2mm 8 7 large x 101mm 4 0 Profond x 287 3mm 11 3 grand Poids 5 1 kg 11 3 lbs Température de fonctionnement 40 C à 60 C 40 F à 140 F au niveau de la mer Y compris le chargement solaire Humidité relative 10 to 100 Altitude de fonctionnement 60 m to ...

Page 22: ...or User Guide T0005158_UG Version 0 34 TEKTELIC Communications Inc Confidential Page 22 of 32 FCC Pt 15 RSS 247 EN 301 489 1 Protection contre les surtensions Toutes les interfaces sont protégées aux niveaux primaires ...

Page 23: ...à la terre de protection de la passerelle Kona Micro Outdoor Gateway est correctement terminée avant de connecter toute autre interface La passerelle Kona Micro Outdoor Gateway contient une suppression de surtension de foudre primaire sur le port d alimentation CC direct le port Ethernet cuivre et le port d antenne RF LoRa Les parafoudres primaires ont la capacité de relier l interface à la limite...

Page 24: ...arte SIM 6 2 Déballage et inspection Les éléments suivants doivent être pris en compte lors du déballage d une nouvelle Kona Micro Outdoor Gateway 1 Inspecter le carton d expédition et signaler tout dommage important à TEKTELIC 2 Le déballage doit être effectué dans un endroit propre et sec lorsque cela est possible 3 Ne jetez pas la boîte d expédition ou les inserts en mousse car ils seront néces...

Page 25: ...ur être monté sur un poteau ou un mur vertical en utilisant le support de montage fourni qui se fixe aux quatre emplacements de vis à l arrière du module illustré dans Figure 9 Figure 9 Emplacements des vis de fixation du support de montage Kona Micro Outdoor Gateway Emplacement de la vis de montage Emplacement de la vis de montage Emplacement de la vis de montage Emplacement de la vis de montage ...

Page 26: ...ure 10 Kona Micro Outdoor Gateway Module avec support de montage Assurez vous que la structure sur laquelle la passerelle est montée est sécurisée et capable de supporter une charge permanente d au moins 136 kg 300 lb La zone ci dessous doit être libre de toute obstruction à l entrée de câble La procédure de montage mural Kona Micro Outdoor Gateway est la suivante 1 Visser le support de montage mu...

Page 27: ... cosse à double trou centrale de 1 4 x 0 75 po jusqu au point de terminaison au sol illustré à Figure 11 La jauge de câble de masse recommandée est 10 AWG Le système de mise à la terre Kona Micro Outdoor Gateway doit être conforme aux codes électriques locaux et nationaux Le conducteur de terre de protection terminé au point de cosse à double trou est obligatoire et doit être la première connexion...

Page 28: ...C directe est isolée du châssis terre à l exception des suppresseurs de surtension primaires Une dérivation de l alimentation en courant continu est normalement reliée à la terre à l extérieur de la Kona Micro Outdoor Gateway généralement à la source d alimentation par convention Le câble d alimentation CC doit être conçu pour une application extérieure conformément aux codes électriques locaux et...

Page 29: ... procédures d enregistrement décrites par le fournisseur de ce système de bande Notez que l antenne du modem 3G 4G est interne à la Kona Micro Outdoor Gateway 6 8 Installation du câble Ethernet en cuivre Le port Ethernet Kona Micro Outdoor Gateway peut être utilisé temporairement pour la mise en service et la maintenance ou peut être connecté en permanence pour le backhaul Lorsque le port n est pa...

Page 30: ...te et le connecteur Ethernet cuivre de cloison RJ45 Pour une installation alimentée par PoE un injecteur de puissance PoE peut être nécessaire 2 Appliquer l alimentation CC à la Kona Micro Outdoor Gateway Le tirage de courant initial devrait être supérieur à 0 1A S il n y a pas de courant la polarité de la connexion du câble d alimentation CC peut être inversée ou la source d alimentation peut ne ...

Page 31: ...mentez la distance entre l équipement et le récepteur Connectez l équipement à une prise d un circuit différent de celui auquel le récepteur est connecté Consulter le revendeur ou un technicien radio TV expérimenté pour obtenir de l aide Pour respecter les limites d exposition RF FCC IC pour la population générale exposition incontrôlée les antennes utilisées pour cet émetteur doivent être install...

Page 32: ...gardez toujours une distance de séparation d au moins 13 8 pouces 35 cm de toute antenne connectée Avant de réparer le produit l antenne ou les câbles désactivez la fonction de transmission ou l alimentation de l unité si vous devez vous rapprocher de la distance de séparation minimale Ce produit doit être installé par des techniciens RF qualifiés ...

Reviews: