background image

 

4

Introduction   

                                                              

 
Thank you for selecting the TP3016M Switching DC Power Supply, please read this user guide before 
the operation. 

 

 

Safety 

 
This manual contains important safety and operation instructions for correct use of power supply. 
Read through the manual and pay attention to the markings and labels of this unit to be connected.  
 
Do not install the substituted spare parts or operate the modification without permission, please 
send the unit back for A/S to our authorized dealers or factory for guaranty of the stability of the unit.      
 
Pay special attention to the information of WANRINGS or CAUTIONS to avoid the damage to power 
supply or connected equipment and human injured.   
 
Please contact the trained technicians for repair service.  

 
Safety Marks  
 

WARNING:  

Summary of Contents for TP3016M Series

Page 1: ...1 User Guide TP3016M Series Switching Mode DC Power Supply...

Page 2: ...n 1 2 Pre Checking 1 3 Quick Start 1 4 Output Checking II Specifications 2 1 Major Specification 2 2 Supplementary Characteristic III Operation 3 1 Keypad 3 2 Front Panel 3 3 Voltage Setting 3 4 Curre...

Page 3: ...3 3 7 Recall Saving Operation 3 8 USB Power Charging IV Calibration 4 1Voltage Calibration 4 2 Current Calibration...

Page 4: ...he markings and labels of this unit to be connected Do not install the substituted spare parts or operate the modification without permission please send the unit back for A S to our authorized dealer...

Page 5: ...result in damage to equipment and improper functioning of power supply Grounding High Voltage Attention on the Warning or Caution Specification Compliance TP3016M Switch mode DC Power Supply is compli...

Page 6: ...ltage and current through the keypad of front panel and save the setting groups for further performance TP3016M also has the 4 digit voltage and current meter as well as the fantastic handheld size Th...

Page 7: ...k points on TP3016M for making sure the proper operation as well as the functions of TP3016M 1 1 Front Panel Description 1 Current Setting Indicator 2 Voltage Setting Indicator 3 Measured Value Displa...

Page 8: ...8 1 2 3 4 5 6...

Page 9: ...ion User Guide 1PC Connect with power and switch on TP3016M the unit start the self system checking the LCD displays 0 5s date of manufacturing production lot model number version number in turn 1 3 Q...

Page 10: ...ecrease the contrast of LCD Press RIGHT arrow key to increase the contrast of LCD V A Key Press the V A key to activate voltage measurement and read the voltage value from display Push the V A key aga...

Page 11: ...button by pressing the direction arrow keys to adjust the voltage value setting Push the V A button to switch the current value setting mode by pressing the direction arrow keys to measured current v...

Page 12: ...power supply under constant current mode 1 Switch on the product the power is off and the indicators of CC CV are light off 2 Adjust voltage value as 30V 3 Connect the resistance 3 50W between output...

Page 13: ...function check This is for checking USB charging function 1 Switch on the product the power is off and the indicators of CC CV are light off 2 Push and light the USB button Adjust the voltage as 5 1V...

Page 14: ...A Measurement Accuracy Voltage 10mV Current 1mA Measured Value Accuracy 25 of output offset Voltage 0 05 5mV Current 0 05 5mA Measurement Speed Voltage 100ms ones Current 100ms ones Setting Value Accu...

Page 15: ...ature 0 to 40 Storage Temperature 20 to 70 III Operation Check the rating label of the power supply and ensure that it complies with the AC mains voltage that is to be used Connect the power supply to...

Page 16: ...g range is from 0 50V to 30V follow the setting steps as below 1 Switch on the power supply 2 Push the OUT button to stop the output setting and light off OUT button 3 Push and light the SET ENTER but...

Page 17: ...1 66A follow the setting steps as below 1 Switch on the power supply 2 Push the OUT button to stop the output setting and light off OUT button 3 Push and light the SET ENTER button the max value posi...

Page 18: ...button again to exit output mode 3 6 Data Saving Operation 1 Under the voltage setting or current setting mode push the STORE button to save the values of voltage or currents into memory of power sup...

Page 19: ...on the power supply 2 Push RECALL button to enter data recall mode the min value position is flickering and displayed RECALL icon in LCD 3 Move UP or DOWN arrow keys to recall the stored group serial...

Page 20: ...can be as 0A Connect the mobile phone via USB cable for power charging The USB ports are suitable for both android mobile phone and l Iphone with automatic check function the product can set the prop...

Page 21: ...er current meter resistance 10 100W into the output terminals calibration follow the steps start from point of zero voltage voltage coefficient current zero current coefficient Hold the SET button to...

Page 22: ...LEFT or RIGHT arrow keys to move the cursors to left or right and push the UP or DOWN arrow keys to adjust the values same as readings of external reference voltage meter then click ENTER button to f...

Page 23: ...keys to move the cursors to left or right and push the UP or DOWN arrow keys to adjust the values same as readings of external reference voltage meter then click ENTER button to finish the current gai...