13
1)
Switch on the product, the power is off and the indicators of CC & CV are light off.
2)
Adjust voltage value is over 5V and current value is over 1A.
3)
Push and light the
OUT
button.
4)
Connect the output terminals by wire for short circuit, the light of
OUT
button is off and output
off.
1.44 The USB charging function check
This is for checking USB charging function.
1)
Switch on the product, the power is off and the indicators of CC & CV are light off.
2)
Push and light the
USB
button. Adjust the voltage as 5.1V and current as 2.0A.
3)
Push and light
OUT
button.
4)
Make sure the power supply under CV mode, the CV indicator is light in LCD.
5)
Setting the current value and make sure the current value can be adjusted from 0A to the max.
value of measuring range. Do not adjust voltage.
II. Specification
2.1 Major Specification