background image

DUOS IoT GATEWAY 

 

Product Manual 

 

19 

 

 

Figure 9 - Graph with the latest registers of the hub 

 

Measurements 

 

The graph on this page shows the transmitter registers that are being received by the gateway. 

The available filters restrict the user's window of interest and select the variables to be 

displayed. 

NOTE: the graph shows the latest registers. Whenever a new value appears, the oldest is 

removed from the graph. 

 

 

Filters 

1.1

 

Default filter 

The default filter displays all measurements from the last two hours received by the gateway, 

from this particular hub. To apply the default filter, click on the 

Clear

 button at the top of the 

graph. 

1.2

 

Filter by date and time 

The date and time filter allows the display of registers that are between the agreeded time 

intervals. 

Summary of Contents for PA160410220

Page 1: ...DUOS IoT GATEWAY Product Manual 1...

Page 2: ...echnical specifications 7 2 2 Technical Drawings 10 2 3 Connections 10 2 4 LED Indicators 11 2 5 Label 11 2 6 Web interface features 12 3 Updates 13 4 Initial configuration 13 4 1 System requirements...

Page 3: ...le page of web interface 25 Figure 16 Page with list of registered users 27 Figure 17 Form to update user information 28 Figure 18 Form to create a new user 29 Figure 19 Form to delete user 29 Figure...

Page 4: ...fields 16 Table 4 Network hubs listing 18 Table 5 Properties page fields and description 22 Table 6 Possible hub states 23 Table 7 Modbus data 24 Table 8 Modbus address identification fields 27 Table...

Page 5: ...hodology design manufacture or necessary corrections Tekon Electronics is not responsible for any error or damage resulting from any misuse of this document and or by third parties NOTE This equipment...

Page 6: ...Gateway has a native integration with the Tekon IoT Platform The gateway uses the Modbus TCP IP and Ethernet communication protocols for sending and receiving data to clouds and the Modbus RTU protoc...

Page 7: ...S WIRELESS GATEWAY 868MHZ IoT PA160410240 DUOS WIRELESS GATEWAY 868MHZ IoT WH PA160410260 DUOS WIRELESS GATEWAY 915MHZ IoT PA160410280 DUOS WIRELESS GATEWAY 915MHZ IoT WH 2 Product This topic describe...

Page 8: ...485 Baudrates 4 8 kbps to 115 2 kbps Data format 8 data bits no parity even odd 1 2 stop bit Available modbus addresses 1 to 247 Ethernet communication port Interface Porta Ethernet RJ45 Speed 100Mbp...

Page 9: ...ess channel 13 26 Wireless network ID Serial number Wireless device ID Serial number Configuration time window at startup 10 seconds Serial Communication RS 485 Modbus Modbus Address 1 Baudrate Bits P...

Page 10: ...Gateway has a compact format compared to the identical category products on the market Figure 1 Technical dimensions of Duos IoT Gateway 2 3 Connections The physical inputs on the product are located...

Page 11: ...a transmission via radio Blue LED General status of operations Red LED RS485 port communications Table 1 LED s colour and description 2 5 Label The DUOS IoT Gateway is identified with a label that con...

Page 12: ...icted only to registered users The security policy is based on the authentication mechanism through the username and password with a function permission scheme that sets the level of access to certain...

Page 13: ...the Duos IoT Gateway are reserved exclusively for Tekon Electronics In case of a severe error contact technical support to assess the problem with your device 4 Initial configuration 4 1 System requi...

Page 14: ...limit the action within the tool The following table shows the limitations for the type of user Feature Permission Role Regular user Administrator Sensor Network Sensor Hub access sensor hubs list x x...

Page 15: ...urements for a specific timeframe or sensor hub x x Data Import Export import data base structure x Data Import Export export database structure x Network access network tab x x Network know which IP...

Page 16: ...ost Recent Values At the top of the page we have the Most Recent Values table that includes the hub registers grouped with the DUOS IoT Gateway at the time of configuration Each row in this table matc...

Page 17: ...gure 6 Detailed information on hub registers Status Overview At the bottom of the page there is an overview of the network status which provides a brief description of the network and gateway status F...

Page 18: ...ate time of registers in seconds Status Hub status Table 4 Network hubs listing The list of associated sensors can be copied or exported The Copy Excel CSV and PDF buttons exemplify the options availa...

Page 19: ...s to be displayed NOTE the graph shows the latest registers Whenever a new value appears the oldest is removed from the graph Filters 1 1 Default filter The default filter displays all measurements fr...

Page 20: ...clock icon to open the time selection window This step is optional When the time is not selected the selection is made automatically according to the current local time 4 Select the hours and minutes...

Page 21: ...n Realtime Measurements Update button located at the top of the graph When you activate this option the From and To fields are empty since the records are appearing in real time Figure 12 Option to up...

Page 22: ...rk id Firmware Version Hub firmware version Communication Period seconds Communication period in seconds Status Hub state Description Hub additional information Synchronize to Cloud Sync enable disabl...

Page 23: ...ption Insert the text in the Description field UTF 8 characters are allowed 3 5 Enable sending registers to the Cloud When a hub is initially registered at the gateway sending data to the cloud is dis...

Page 24: ...ddress Register Value Register values in hexadecimal format Register Type Type of object linked to the register Register Format Register data format Table 7 Modbus data Figure 14 Hub modbus registers...

Page 25: ...terfaces Cloud Services configure cloud services Monit service access monitoring tool System system configuration and control NOTE each task that will be described in the following steps can only be p...

Page 26: ...the communication module exchange per unit of time In the BAUDRATE field click on the configured option and select one of the available values in the selection box that will be displayed NOTE this fie...

Page 27: ...e The USERS tab allows to Edit information of existing users Delete users Create users Each user has the following attributes Username username used to log in Password password that validates the user...

Page 28: ...7 Form to update user information 3 Do your changes Please note the following conditions FIRST NAME and LAST NAME attributes are optional It can be left blank the role of Administrator can be assigned...

Page 29: ...E and LAST NAME Click on the ADMIN checkbox if you want to assign administrator permissions to the new user Click on ADD button to create the user account Figure 18 Form to create a new user 4 3 4 Del...

Page 30: ...le hubs or click on SELECT ALL HUBS if you want to select all hubs If you choose to select all hubs and want to undo the selection click on SELECT NONE 3 Click on DOWNLOAD CSV button to export the dat...

Page 31: ...ot selected the selection is automatically made according to the current local time 4 Select hours and minutes 5 In the To field click on the calendar icon to open the calendar window 6 Replicate step...

Page 32: ...the several interfaces of the gateway network and their status or configuration The interfaces are listed based on the following parameters Interface parameters Description Interface Network interfac...

Page 33: ...e the DHCP IP Address Netmask and Gateway parameters This feature allows the assignment of the gateway IP within the network to occur automatically or manually Click on the MANAGE button to open the i...

Page 34: ...h assumes the role of establishing the time window that the server is using as a reference associated with recording the date and time of all processes You can choose to use the time server configured...

Page 35: ...redentials are configured and tested to enable the sending of data to the Tekon IoT Platform Within SETTINGS menu click on the CLOUD SERVICES tab Figure 27 Page to configure the connection to Tekon Io...

Page 36: ...te Credentials option allows the credentials to be given as valid and saved in the database as the correct ones If the credentials have not been tested and are incorrect the connection will not be mad...

Page 37: ...nes If the credentials have not been tested and are incorrect the connection will not be made 4 7 Monit The DUOS IoT Gateway follows with a web monitoring tool provided by third parties called Monit w...

Page 38: ...al 1 In the new window place the access credentials provided below Username admin Password bresimar Table 10 Credentials for access Figure 31 Window to enter credentials 2 Click on OK to validate cred...

Page 39: ...n this manual You can find more information on the tool owner s documentation page https mmonit com documentation 4 8 System In this page you will have access to information about the DUOS IoT Gateway...

Page 40: ...fies the gateway of the local IP network Once changed the gateway can be detected and accessed on the local IP network through the new hostname with the suffix local 4 8 2 Update timezone 1 Click in t...

Page 41: ...dure does not turn off the DUOS IoT Gateway It just turns off all the services 4 8 5 Reset factory settings ATTENTION this action resets the system settings to their initial state Any changes made wil...

Page 42: ...ess gateway IP address Port 1502 Table 11 Data for connection via Modbus Once connected requests for reading and writing can be carried out in the registers Currently the allocation of addresses to re...

Page 43: ...f this step is not done automatically there is no DHCP server which provides and assigns IP addresses automatically on your network Check your network for a DHCP server Verifique o estado do par metro...

Page 44: ...V3 1 1 EN 301 489 1 V2 2 0 EN 301 489 3 V2 1 1 8 Glossary Terms Definition DHCP Dynamic Host Configuration Protocol used to configure network identifiers automatically Gateway Device with physical int...

Page 45: ...monitoring Modbus Data communication protocol used in industrial automation systems NTP Network Time Protocol Used to keep a system s timekeeping synchronized with a time server Sensor hub Device tha...

Page 46: ...IoT GATEWAY Product Manual 46 Tekon Electronics Avenida Europa 460 Quinta do Sim o Esgueira 3800 230 Aveiro Portugal T 351 234 303 320 M 351 937 270 062 sales tekonelectronics com www tekonelectronics...

Reviews: