Installing & Working With System Components 4-2
•
W15: Selects the desired multiplier to set the internal CPU clock speed (2, 3 or 4
times the external bus speed):
- Shorted: 2X (or 4X for AMD 5x86-133 only),
- Or open: 3X.
For DX microprocessors, external bus speed is set to the maximum CPU internal clock
speed or less.
For DX2 microprocessors, external bus speed is set to half the maximum CPU internal
clock speed or less.
For DX4 microprocessors, external bus speed is set to one third the maximum CPU
internal clock speed or less.
For 5x86 microprocessors, external bus speed is set to one fourth the maximum CPU
internal clock speed or less.
Jumper locations and settings appear in Section 3 of this manual.
4.01.2 CPU FAN
You must use a 5V CPU fan on the VIPer808. Pin 1 of the fan connector at J11 is supplied
with 5V (not 12V). A 5V CPU fan assembly (including cables) is available from
TEKNOR.
IMPORTANT: Use a 5V CPU fan on the VIPer808.
Summary of Contents for VIPer808
Page 21: ...Installing Memory 2 3 DIAGRAM 2 1 Assembly Top...
Page 22: ...Installing Memory 2 5 DIAGRAM 2 2 Assembly Bottom...
Page 26: ...Setting Jumpers 3 3 DIAGRAM 3 1 VIPer808 Jumper Locations with Default Settings...
Page 28: ...Setting Jumpers 3 6 TABLE 3 1a Jumper Settings W1 W4 W13 W14...
Page 29: ...Setting Jumpers 3 7 TABLE 3 1b AMD DX2 DX4 CPU Jumper Settings W1 W15 W15C...
Page 30: ...Setting Jumpers 3 8 TABLE 3 1c AMD 5x86 CPU Jumper Settings W1 W15 W15C...
Page 31: ...Setting Jumpers 3 9 TABLE 3 1d Intel CPU Jumper Settings W1 W15 W15C...
Page 32: ...Setting Jumpers 3 10 TABLE 3 1e SGS CPU Jumper Settings W1 W15 W15C...
Page 33: ...Setting Jumpers 3 11 TABLE 3 1f Jumper Settings W18 W20 W23...
Page 92: ...Memory I O Maps B 1 APPENDIX B MEMORY I O MAPS B 01 MEMORY MAPS DIAGRAM B 1 Memory Map Diagram...
Page 96: ...Mechanical Layout Block Diagram C 3 DIAGRAM C 1 Mechanical Specifications...