9
6
- finding mode this mode of operation the patented tried-and-space at the same time, underground imaging
modes. When this mode is selected on the screen after the setting is made of the soil in a straight line is observed.
The shapes of metal detection on this line upwards, downward shapes how we perceive space. This mode to the
ground during use of the coil in case of a change in the distance can lead to erroneous information.
Attention! This product is basically a metal detector. Finder space. In space mode in use, detection distance,
detection distance is lower than are realized as metal. Space is a feature of the discovery process it should be
noted that the secondary detector. Since the basic operation of the detector metal detection, metal detection
performance will be the difference between gap detection performance.
AVR
: detection of the detector that you will use for the calculation of the filter coefficient that determines the
part. The parameter used here is also increasing in direct proportion to the level of filtering. Filtering the electrical
noise reduces the sensitivity of the detector to high. However, the speed and accuracy of detection reduces. High
AVR sensitivity value should not be set necessarily to live and work in situations that should be taken into account
a slowdown in losses. The value should not be increased and therefore unnecessary AVR should be kept as low as
possible.
FRK:
you set the ground tone volume of the detector, if desired the part where Semin muted state. The sound
must be set to 0 if the ground is required.
TSpd:
the land of the detector that will be set with the automatic setting, adjust the speed to be set is the part
where what happens to the soil. In this section, The parameter is set to 0 when the soil is done automatically in
the setting of the detector. Any number except 0 when the parameter is set, the detector automatically begins
adjusting to the changes of the soil. This setting is made according to the speed parameter value takes place. The
speed setting is directly proportional to the value of the parameter. Value grows as the speed of adjustment is
increasing.
Attention! The recommended setting for this section is high in mineral soils, mineral soils of the low values in the
selection. If the value for this setting and leave at 5 If you understand the logic.
Tlmt:
the land of the automatic setting of the detector is the part which determines what will be done to detect
level. In this section, The number to be selected as one grows higher detection will automatically reset. Figure 9 in
this section if you selected as the automatic setting as the infinite limit of soil is determined.
Attention! The recommended setting for this section is high in mineral soils, mineral soils of the low values in the
selection. If you understand the logic, please leave at 9 If the value for this setting.
Attention! Automatic soil setting within the limit specified in the selected detector for inability to comply with
Section tkmt will make all the perception. How is this being complied with in a time of tspd in part by the selection
of the speed will be determined. In the light of this information if the user waits motionless on a metal metal
detector can perform the attunements, and normal soil are passed onto an automatic adjustment in the back
ground until you make unless may perform metal detection.