BD-1/07-002
25
15.4. User Phone Numbers Test
System calls user and sends alarm tone. Answer phone then [Press] “*” and enter
your code.
16. MANUAL CONTROL OF PGM OUTPUT
User can control status of PGM(s) outputs manually.
* There is no PGM2 in VAP2xx, VAP3xx.
** There is noPGM3 in VAP2xx, VAP3xx and VAP404.
PGM changes its position (ON→OFF, OFF→ON).
17. TIME AND DATE SETTING
Master user can set time and date according to following table.
Address
Sample
LCD Menu
Time
01 01
For 9:05 enter 0905.
Basic Settings/Clock Setting/Time
Date
01 02
12/05/2004
(dd/mm/yyyy)
enters 120504.
Basic Settings/Clock Setting/Date
17.1. Setting Time
For VPC016, VPC104, VPC108, VPC116 and VPC132 keypads;
For VPC301 keypad;
[Press] (Test) key long until you hear long beep.
[Press] and then key (for user phone-1)
key (for user phone-2)
key (for user phone-3)
:
:
[Press] (Test) key long until you hear long beep.
[Press] and then key (for PGM1)
key (for PGM2)*
key (for PGM3)**
:
:
Enter to the master program.
[Enter] (Program) key long until you hear a long beep.
[Enter] Your 4 digit master code.
[Enter] address 01 01.
[Enter] Time as shown above table.
[Enter] (Ok) key.
Enter to the master program.
[Enter] (Program) key long until you hear a long beep.
[Enter] Your 4 digit master code.
[Enter] Basic Settings/Clock Setting/Time.
[Enter] Time as shown above table.
[Enter] (Ok) key.
Summary of Contents for VAP Series
Page 1: ...VAP Series Alarm System User s Manual Issue Date 13 02 2007 TD 1 07 002 ...
Page 33: ...BD 1 07 002 32 ...
Page 34: ...BD 1 07 002 33 ...