Scenes (System Override)
Section M
Scenes provide an easy way to save energy while away on vacation, or override
a programmable schedule when plans change.
Away Key
-----------------------------------------------------------
-----------------------------------------------------------
This thermostat includes an Away Key to quickly turn down the heating temperatures
and increase the cooling temperatures on all thermostats and suspend heating
the domestic hot water tank to maximize energy savings. To enable, go the Scene
menu and set Away Key to on.
Additional Scenes
---------------------------------------------------
---------------------------------------------------
Additional energy saving scenes are available when a User Switch or Gateway is
installed. A complete listing of each scene is shown below.
Scene
Number
Scenes
= None
Operation
Scenes
= Away
Operation
Scenes
= All
Operation
Scenes
= Guest
Operation
1
Permanent
or Schedule
Permanent
or Schedule
Permanent
or Schedule
Permanent
2
Scene 1
Away
Away
Away
3
Scene 1
Scene 1
Permanent
Permanent
4
Scene 1
Scene 1
Configurable
Permanent
5
Scene 1
Scene 1
Permanent
or Schedule
Permanent
or Schedule
6
Scene 1
Scene 1
Temporary
3 Hours
Permanent
7
Scene 1
Scene 1
Temporary
4 Hours
Permanent
8
Scene 1
Scene 1
Temporary
8 Hours
Permanent
To activate the Away scene, touch “Going Away” on the
screen.
Select PERM (permanent) or a number of days using
the or arrow. Range is 1 to 180 days.
Press the home button to accept the setting or leave
the screen untouched for several seconds.
“Scene Away” is displayed on the home screen until
the number of days expires.
Touch “Cancel Away” to cancel at any time.
Note:
The temperature is not adjustable while the thermostat
is in Away.
•
•
•
•