ELECTRICAL CONNECTION
•
The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician who is aware of the normative regulations and who respects
them scrupulously.
•
The electrical parts should always be protected after the building-in.
•
The necessary data of connection are on the stickers placed on the bottom of the appliance.
•
The appliance should be separated from the mains by using a multipolar circuit breaker. The
contact opening must be at least 3 mm.
•
The electrical circuit must be separated from the mains by using adapted devices, such as
circuit breakers, fuses or (differential) contactors.
•
If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
•
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob or
oven.
Caution!
This appliance can only be connected to a network 230 V~ 50/60 Hz.
You should always connect the earth wire.
Respect the connection diagram.
Use the connecting cable that is attached to the device.
The green / yellow wire corresponds to the earth wire, the blue wire corresponds to the neutral wire
and the brown wire correspond to the phase.
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Caution! Be careful to correctly engage and tighten the cables.
Mains
Connection
Cable diameter
Cable
Protection calibre
230V~ 50/60Hz
1 Phase + N
3 x 1,5 mm²
H 05 VV - F
H 05 RR - F
16 A *
We cannot be held responsible for any incident resulting from incorrect connection or which could
arise from the use of an appliance which has not been earthed or has been equipped with a faulty
earth connection.