Instructions for Use
40
Placing and Installation
Choosing the Right Place
Place the appliance in dry and well ventilated room. Allowed ambient
temperature depends on the model (class) of the appliance and is
stated on the rating plate of the appliance. Never place the appliance
near heat emitting devices (e.g. cooker, radiator, water heater and
similar devices) and do not expose it to direct sunlight.
The appliance should be positioned at least 3 cm away from the
electric or gas cooker and at least 30 cm away from the oil or coal
stove. If this is not possible, use an appropriate insulation.
Class
Ambient temperature
SN (sub-normal)
from + 10°C to + 32°C
N (normal)
from + 16°C to + 32°C
Connection to Power Supply
Connect the appliance with the cable and plug to the power supply
socket outlet with a ground terminal (safety socket).
Required nominal voltage and frequency are indicated on the rating
plate.
The connection to the mains supply and earthing have to be made
according to current standards and regulations. The appliance resists
temporary voltage tolerance up to -15 to +10 %.
Adjusting the height of the appliance
The appliance is equipped with four adjustable legs, so that the height
may be adjusted from 82 to 90 cm. The height must be adjusted prior
building the appliance into the opening slot, and it should be set at such
height that the top panel of the appliance fits exactly below the kitchen
worktop (see
Mounting Instructions
).