Start-up of the cabinet 

 

Before use, we recommend that the cooler is cleaned, see the section on maintenance and cleaning. 
 

Important ! 

If the cooler has been vertically placed during transport, please wait 2 hours before starting up the 
cabinet. 

 
Thermostat 

 
The thermostat is placed in the control panel, see fig. 2.0. 
 

Fig. 2.0 

 

The thermostat has been pre-set and in most cases it is not necessary to adjust the settings.  
 
When turning on the cabinet the display will show the current temperature in the cabinet.  
 

Display set temperature: 

 Press this key and the display will show the set temperature. Press the key again to return to 

          normal reading 
 

Set new temperature: 

 Press this key continuously for more than 3 seconds and the display shows the set 

temperature. 

 Press this key to increase the set temperature. 

 Press this key to lower the set temperature. 

 Press this key to save the new settings. The display will flash with the new value and will 

          then return to normal reading. 
 

Alarm codes: 

 

‘P1’  

Flashing in the display: indicates that the cabinet sensor is defective. 

         The cabinet will strive to keep the set temperature until it has been repaired. 
 

‘P2’  

Flashing in the display: indicates that the evaporator sensor is defective. 
This does not influence the operation of the cabinet, but should be repaired as soon as 
possible.  

 

 
 

Summary of Contents for VOC100

Page 1: ...1 Model VOC100 Brugsvejledning DK 3 Users manual UK 6 114 160412...

Page 2: ...Opstart 3 Termostaten 4 Afrimning 4 Lys 5 Vedligeholdelse 5 Service 5 Bortskaffelse 5 UK Contents Important safety instructions 6 Unpacking and installation 6 Electrical connection 6 Start up of the...

Page 3: ...beregnet for tilslutning til 220 240 V 50 Hz Tilslutningen skal ske ved en stikkontakt der b r v re let tilg ngelig Denne k ler skal ekstrabeskyttes if lge st rkstr msreglementet Dette g lder ogs selv...

Page 4: ...den nye indstilling display blinker med den nye v rdi og vender derefter tilbage til normal visning Fejlkoder P1 Blinkende i display betyder at skabets rum f ler er defekt tilkald service Skabet vil t...

Page 5: ...rflader og p det indvendige k lesystem Der m ikke spules med vand ind i kompressorrummet da der kan opst kortslutninger og skader p de elektriske dele Service K lesystemet er et hermetisk lukket syste...

Page 6: ...ctrical appliances inside the refrigerated storage compartment Any repair of the appliance should be carried out by a skilled technician EN 60335 2 89 2010 Unpacking and installation Carefully examine...

Page 7: ...splay will show the set temperature Press the key again to return to normal reading Set new temperature Press this key continuously for more than 3 seconds and the display shows the set temperature Pr...

Page 8: ...ance and cleaning Switch the freezer off at the socket The cabinet must be periodically cleaned Clean the external and internal surfaces of the cabinet with a light soap solution and subsequently wipe...

Page 9: ...osal Disposal of the cooler must take place in an environmentally correct way Please note existing regulation on disposal There may be special requirements and conditions which must be observed A13040...

Reviews: