Technical specifications

Measurement range

20°C / 42,2°C

Screen resolution

0,1°C

Precision

from 32°C to 42°C : +/- 0,2°C
< 32°C and > 42°C : +/- 0,3°C

Operation conditions -  

+16°C / +35°C

room temperature

Relative humidity less than 85%

Storage conditions 

- 20°C / +80°C

Relative humidity less than 95%

Energy source 

1 lithium battery 3V type CR2032

Service life: approximately 5000 measures

In compliance with the European directive 93/42 (Medical appliances) and EN 12470-5 
(medical thermometer). 
CE 0120 marking

Comments: these technical specifications may be subject to modifications to improve the
appliance, without prior warning.

Made in China by Hubdic CNS
Imported and distributed by TEFAL SAS
Italia - EC Representative: Bremed Italia S.r.l. Via Alviano 4/1 Gorizia - Italia 
TEFAL SAS BP 89 74156 RUMILLY Cedex FRANCE

Before first use

Installing the battery

The appliance is delivered with a lithium battery 3V (CR2032) already in place.

At the first use, open the battery cover then remove the strip which ensures the protection of the
battery (fig. 1/fig. 2). Replace the cover (fig. 3).

Functionning

Ear measurement

• Remove the protection cap. 

• To switch on press and hold the button          until the indications in fig. 4 are displayed in the

screen the appliance automatically displays the Ear mode. The screen shows the corresponding
function fig. 5 and the luminous diode corresponding to the symbol          blink 5 times.

• Gently pull the ear upwards and backwards to straighten the ear canal. Insert the thermometer

into the ear canal fig. 6.

Description

1 - Lens
2 - Probe
3 - Battery compartment
4 - Luminous diodes to show temperature mode : ear or forehead 
5 - Screen 
6 - Take temperature and memory function button
7 - On/Off and Ear or forehead temperature Mode button 
8 - Protection / vertical storage cap.

Precautions for use

This ear and forehead thermometer receives the infra-red rays emitted by the skin’s surface and
in the ear drum area. It allows you to check your child’s temperature easily. This is how to use
the appliance:
• The TEFAL thermometer is exclusively dedicated to take ear or forehead temperatures.

We would like to re-iterate that this appliance does not replace the advice of a doctor. In case of
doubt or fever, contact your doctor. TEFAL cannot be held responsible for poor interpretation of results.

The simple take of temperature cannot be considered as a medical advice

, DO NOT

modify the proportion of any drugs prescribed by your doctor without seeking medical advice first.

• To ensure the reading is accurate, the probe and the lens must be absolutely clean.
• Do not use the thermometer if it has been dropped or shows any signs of damage
• Always place the protection cap back after use.
• In cases of movement from one room to another, wait for half an hour minimum before using

the appliance.

• Wait for half an hour after physical training, bathing or eating before measuring temperature.
• Keep the thermometer out of reach of children.
• Do not expose the thermometer:

- To any warm sources (radiator, sun rays, ...)
- To dust or humidity.

• Never immerse the thermometer in liquid.
• Do not touch the lens with your fingers.

BODY TEMPERATURE: the normal human body temperature varies during the day. It is measured
along a scale of values defined according to the part of the body where the temperature is taken:
- Rectal measurement: 36,6° - 37,8°C
- Axillary measurement (under the arm): 34,7° - 37,3°C
- Oral measurement (in the mouth) or forehead: 35,5° - 37,5°C
- Ear measurement: 35,8° - 37,8°C

Warning, this appliance is not suitable for dectecting  hypothermia.

Average temperatures 

Forehead Ear  Rectal  Oral  Axillary

temperature

temperature

temperature

temperature

temperature

36,1°C

36,4°C

37,0°C

36,6°C

36,1°C

GB

24

25

TE211422 Notice Thermo Auri 13 L  13/10/06  12:29  Page 24

Summary of Contents for BH1110

Page 1: ...CULAIRE ET FRONTAL infrared ear and forehead thermometer www groupeseb com 211422 10 06 R C S TEFAL annecy B 301 501 920 R f 2000942790 RO HR IR SK H BG CZ GB F PL UA RUS TE211422 Notice Thermo Auri 1...

Page 2: ...8 1 2 3 4 5 6 7 fig 2 fig 1 fig 5 fig 6 fig 4 fig 8 fig 7 fig 3 TE211422 Notice Thermo Auri 13 L 13 10 06 12 29 Page 2...

Page 3: ...C 32 C 42 C 0 2 C 32 C 42 C 0 3 C 16 C 35 C 85 20 C 80 C 95 1 3 CR2032 5000 93 42 EN 12470 5 CE 0120 Hubdic CNS Made in China by Hubdic CNS TEFAL SAS Bremed Italia S r l Via Alviano 4 1 Gorizia TEFAL...

Page 4: ...fig 4 fig 7 5 fig 8 o OFF 60 10 MEMORY 10 SAV TEFAL 16 C 35 C 30 6 7 RUS TE211422 Notice Thermo Auri 13 L 13 10 06 12 29 Page 6...

Page 5: ...TEFAL fig 1 CR2032 3 fig 3 1 2 3 4 5 6 7 8 30 36 6 37 8 C 34 7 37 3 C 35 5 37 5 C 35 8 37 8 C 36 1 C 36 4 C 37 0 C 36 6 C 36 1 C UA 8 9 TE211422 Notice Thermo Auri 13 L 13 10 06 12 29 Page 8...

Page 6: ...3 CR2032 5000 93 42 EN 12470 5 CE 0120 Hubdic CNS TEFAL SAS Bremed Italia S r l Via Alviano 4 1 Gorizia TEFAL SAS BP 89 74156 RUMILLY Cedex 3 CR2032 fig 1 fig 2 fig 3 fig 4 fig 5 5 fig 6 fig 4 fig 7 5...

Page 7: ...10 MEMORY 10 16 C 35 C 30 fig 1 CR2032 3 fig 3 UA 12 13 TE211422 Notice Thermo Auri 13 L 13 10 06 12 29 Page 12...

Page 8: ...a na kt rej temperatura jest mierzona Pomiar w odbycie 36 6 37 8 C Pomiar pod pach pod ramieniem 34 7 37 3 C Pomiar doustny w ustach lub czo owy 35 5 37 5 C Pomiar douszny 35 8 37 8 C Uwaga to urz dz...

Page 9: ...wo ci nale y korzysta z pomiaru dousznego przypominamy e mi dzy pomiarem dousznym i czo owym wyst puje znaczna r nica Wy czenie Urz dzenie mo na wy czy r cznie przez naci ni cie i przytrzymanie przyci...

Page 10: ...teur rayons du soleil A la poussi re l humidit Ne pas plonger le thermom tre dans un liquide Ne pas toucher la lentille du thermom tre avec les doigts TEMPERATURE DU CORPS la temp rature normale du co...

Page 11: ...e front avant la mesure et de nettoyer la lentille En cas d cart important ou de doute c est la mesure auriculaire qui doit tre privil gi e nous vous rappelons qu il y a un cart significatif entre une...

Page 12: ...ratures possibles La temp rature mesur e est en dehors de la plage de temp ratures possibles Changer la pile Si l cran reste blanc contacter un centre SAV TEFAL Changer la pile Renouveler la prise de...

Page 13: ...ecautions for use This ear and forehead thermometer receives the infra red rays emitted by the skin s surface and in the ear drum area It allows you to check your child s temperature easily This is ho...

Page 14: ...The temperature is automatically recorded Notice For optimal precision the ear should not be obstructed by wax or a plug Do not use this thermometer with an ear infection otitis Moreover if your chil...

Page 15: ...zdroji tepla radi toru slune n m paprsk m prachu i vlhkosti Nepono ujte teplom r do tekutiny Nedot kejte se o ky teplom ru prsty TEPLOTA T LA norm ln teplota lidsk ho t la se i u t ho jedince v pr b h...

Page 16: ...elo a o istit o ku V p pad v znamn odchylky nebo pochybnosti je t eba d t p ednost u n mu m en p ipom n me e mezi u n m a eln m m en m existuje v znamn odchylka Vypnut P stroj se vyp n manu ln tak e...

Page 17: ...v m m en m a stejn se pokra uje i d le P e ten teplot ulo en ch do pam ti V robek mus b t vypnut Dr te tla tko stisknut dokud se nezobraz MEMORY Informace se na displeji objevuj st dav P klad Chcete l...

Page 18: ...e v kone n ku 36 6 37 8 C Meranie v podpa 34 7 37 3 C Meranie v stach alebo na ele 35 5 37 5 C Meranie v uchu 35 8 37 8 C Pozor tento pr stroj sa nehod na zis ovanie hypotermie Priemern teploty Teplot...

Page 19: ...m sa odpor a osu i elo a o isti o ovku V pr pade v znamnej odch lky alebo pochyby treba d t prednos u n mu meraniu pripom name e medzi u n m a eln m meran m existuje v znamn odch lka Vypnutie Pr stro...

Page 20: ...n kell alkalmazni A TEFAL h m r kiz r lag a f l s a homlok h m rs klet nek m r s re alkalmas Szeretn nk megism telni hogy a k sz l k semmilyen esetben sem helyettes ti az orvos szakv lem ny t Amennyib...

Page 21: ...ts gei vannak akkor r szes tse el nyben a f lben t rt n m r st Felh vjuk a figyelm t hogy jelent s elt r sek vannak a f ln l s a homlokn l t rt n m r sek k z tt Kikapcsol s A k sz l k k zileg kikapcso...

Page 22: ...klet a lehets ges h m rs klet tartom ny alatt helyezkedik el A m rt h m rs klet a lehets ges h m rs klet tartom ny felett helyezkedik el Cser lje ki az elemet Ha a k perny feh r marad forduljon egy mi...

Page 23: ...2032 5 000 93 42 EN 12470 5 CE 0120 Hubdic CNS Made in China by Hubdic CNS TEFAL SAS Imported and distributed by TEFAL SAS Bremed Italia S r l Via Alviano 4 1 Gorizia Italia EC Representative Bremed I...

Page 24: ...fig 4 fig 7 5 fig 8 OFF 60 10 MEMORY SAV TEFAL 16 C 35 C 30 BG 46 47 TE211422 Notice Thermo Auri 13 L 13 10 06 12 29 Page 46...

Page 25: ...anta m surarea exact capul de citire a aparatului i n special lentila trebuie s fie perfect curat Evita i ocurile i c derile termometrului n caz c apar astfel de situa ii asigura i v c termometrul fun...

Page 26: ...ea nainte de a lua temperatura i s cur a i lentila n cazul unei diferen e importante sau dac ave i dubii este prioritar valoarea ob inut prin m surare auricular v reamintim c exist o diferen important...

Page 27: ...urilor posibile Temperatura m surat este sub domeniul temperaturilor posibile Temperatura m surat este n afara domeniului temperaturilor posibile nlocui i bateria Dac ecranul nu afi eaz nimic contacta...

Page 28: ...nje 36 6 37 8 C Osnovno mjerenje ispod pazuha 34 7 37 3 C Oralno ili eono mjerenje u ustima 35 5 37 5 C U no mjerenje 35 8 37 8 C Pa nja ovaj ured aj nije prikladan za utvrd ivanje hipotermije Srednje...

Page 29: ...a i o istiti le u U slu aju bitnih razlika ili sumnje u no mjerenje je to koje treba imati prednost podsje amo vas da postoji zna ajna razlika izmed u u nog mjerenja i eonog mjerenja Zaustavljanje Ure...

Page 30: ...NO Pri postavljanju baterije uvijek sa ekajte pola sata prije uporabe ured aja Odr avanje istite tijelo toplomjera mekom krpicom istite sondu toplomjera uz pomo dezinfekcijske krpe ili uz pomo vate na...

Page 31: ...60 61 TE211422 Notice Thermo Auri 13 L 13 10 06 12 29 Page 60...

Page 32: ...62 63 TE211422 Notice Thermo Auri 13 L 13 10 06 12 29 Page 62...

Page 33: ...64 65 IR TE211422 Notice Thermo Auri 13 L 13 10 06 12 29 Page 64...

Page 34: ...66 67 IR TE211422 Notice Thermo Auri 13 L 13 10 06 12 29 Page 66...

Page 35: ...68 69 TE211422 Notice Thermo Auri 13 L 13 10 06 12 29 Page 68...

Page 36: ...70 TE211422 Notice Thermo Auri 13 L 13 10 06 12 29 Page 70...

Reviews: