S
LURRY SPREADER
,
O
THER TYPE
(H
YDR
.)
T
EE
J
ET
5000
O
PERATORS MANUAL
7.20
AUTO/MAN:
Select between automatic or manual operation. If manual
operation is selected,
MAN
will flash in the lower part of the
display,
+
and
–
will also appear as function keys.
+:
Is only displayed if manual operation is selected.
Increase application. When this key is pressed, the application
rate is increased. The speed at which the rate increases depends
on the speed of the regulating system.
-:
Is only displayed if manual operation is selected.
Decrease application. When this key is pressed, the application
rate is decreased. The speed at which the rate decreases
depends on the speed of the regulating system.
Pressing the
”NEXT PAGE”
key displays the
first
available functions.
MANUAL BOOM SECTION CONTROL:
It is possible to work with up to 9 individual boom sections (presupposes
encodement of the sections under DISTRIB. WIDTH in encode).
These boom sections can be opened/closed manually with the numerical keypad.
When the numerical key that corresponds to the boom section is pressed for
approx. 3 seconds the boom section is opened or closed.
If the spreader has 5 boom sections giving a total working width of 16 metres, the
boom sections can be encoded as follows:
Sections 1 and 5 = 50 centimetres
Sections 2 and 4 = 150 centimetres
Section 3 = 1200 centimetres
It is now possible to reduce the spreading width from 16M to 15M by closing
sections 1 and 5, closing sections 2 and 4 thereafter reduces the working width to
12M.
Which sections are open/closed is displayed on the screen.
BOOM SECTIONS ON/OFF:
Pressing this key starts or stops slurry spreading. Can
only be used if
“SLURRY SPREADER”
has been
selected as the implement sensor under
“IMPLEM.
SENSOR”
in encode.
Also works as the area override sensor.
The picture to the left shows a slurry spreader with 2
boom sections encoded. One section is open and one
section is closed. To open the other section, press the
number
2
on the numerical keypad for approx. 3
seconds. To close the first section press number
1
on
the numerical keypad for approx. 3 seconds.
I
When the area override sensor is activated (not
counting area) “I” is displayed and all sections will
disappear.
Summary of Contents for 5000
Page 56: ...SPRAYER TEEJET 5000 OPERATORS MANUAL 3 14 ...
Page 58: ......
Page 80: ...FERTILISER DISTRIBUTOR OTHER TYPE WITH REG TEEJET 5000 OPERATORS MANUAL 4 22 ...
Page 92: ...FERTILISER DISTRIBUTOR BØGBALLE TEEJET 5000 OPERATORS MANUAL 4 34 ...
Page 118: ...FERTILISER DISTRIBUTOR BREDAL HYDR B TEEJET 5000 OPERATORS MANUAL 4 60 ...
Page 132: ...FERTILISER DISTRIBUTOR BREDAL HYDR K TEEJET 5000 OPERATORS MANUAL 4 74 ...
Page 146: ...FERTILISER DISTRIBUTOR BREDAL K RAMP TEEJET 5000 OPERATORS MANUAL 4 88 ...
Page 182: ...FERTILISER DISTRIBUTOR RAUCH AXERA H TEEJET 5000 OPERATORS MANUAL 4 124 ...
Page 194: ......
Page 253: ...TEEJET 5000 OPERATORS MANUAL SEED DRILL LEMKEN 5 59 ...
Page 254: ...SEED DRILL LEMKEN TEEJET 5000 OPERATORS MANUAL 5 60 ...
Page 276: ...BALER TEEJET 5000 OPERATORS MANUAL 6 8 ...
Page 278: ......
Page 291: ...TEEJET 5000 OPERATORS MANUAL SLURRY SPREADER OTHER TYPE 7 13 ...
Page 292: ...SLURRY SPREADER OTHER TYPE TEEJET 5000 OPERATORS MANUAL 7 14 ...
Page 350: ...FITTING INSTRUCTIONS TEEJET 5000 OPERATORS MANUAL 12 2 ...
Page 352: ...FITTING INSTRUCTIONS TEEJET 5000 OPERATORS MANUAL 12 4 GENERAL OVERVIEW ...
Page 365: ...TEEJET 5000 OPERATORS MANUAL FITTING INSTRUCTIONS 12 17 ...