T
EE
J
ET
5000
O
PERATORS MANUAL
F
ERTILISER DISTRIBUTOR
,
R
AUCH
A
XERA
H
4.121
FERTILISER CALIBRATION:
Prepare the spreader as follows before the fertiliser calibration procedure takes
place:
1.
To ease the calibration procedure it is only necessary to calibrate one section
of the spreader. Using the switch box open this one section and shut all of
the other sections. The main on/off switch should be set to off.
NOTE:
The calibration procedure can be done using both sections. The
optimal accuracy is achieved using both sections, but an adequate
accuracy can be achieved by measuring the amount of fertiliser
from one section.
If both sections are used for calibration, the total amount from both
sides must be encoded.
Do
not
open any other sections during the calibration procedure.
2.
3 different “fixed” application rates used during operation must be encoded
now. Press thereafter the
“CALIB. PROCED”
key.
3.
The minimum and maximum forward speed at which the spreader will be
operating must be encoded by moving the cursor and then using the
numerical keypad. Encodement range
3.0 – 30.0 KPH
4.
Start the machine and let it run at the recommended speed.
5.
Press
the
“START”
key and the computer is ready for
CALIBRATION TEST
1
.
6.
Switch the main on/off switch to ON.
The
TeeJet 5000
will count seconds under the test.
To ensure accurate calibration, use as much fertiliser as possible.
7.
When a suitable amount has been released switch the spreader off.
8.
Weigh the released fertiliser as accurately as possible, remember to deduct
the weight of the bucket. Encode the amount with 1 decimal using the
numerical keypad.
9.
Press
the
“CALIB. TEST 2”
key and the computer is ready for calibration
test 2, proceed as described for calibration test 1 (steps 4-7).
10.
Press
the
“CALC. AND SAVE”
Key and it is possible to save the calibration
result in 1 of 3 positions. Select which position to save the result in using the
arrow keys, press thereafter the
“SELECT”
key.
If the “CALCULATE” key is pressed, the calibration will be used until
another calibration procedure takes place or another calibration
(previously saved) is selected.
If
the
metered/encoded
amounts from the calibration procedure are not
accurate enough for the TeeJet 5000, an warning will be given and the
calibration procedure must be carried out again.
Summary of Contents for 5000
Page 56: ...SPRAYER TEEJET 5000 OPERATORS MANUAL 3 14 ...
Page 58: ......
Page 80: ...FERTILISER DISTRIBUTOR OTHER TYPE WITH REG TEEJET 5000 OPERATORS MANUAL 4 22 ...
Page 92: ...FERTILISER DISTRIBUTOR BØGBALLE TEEJET 5000 OPERATORS MANUAL 4 34 ...
Page 118: ...FERTILISER DISTRIBUTOR BREDAL HYDR B TEEJET 5000 OPERATORS MANUAL 4 60 ...
Page 132: ...FERTILISER DISTRIBUTOR BREDAL HYDR K TEEJET 5000 OPERATORS MANUAL 4 74 ...
Page 146: ...FERTILISER DISTRIBUTOR BREDAL K RAMP TEEJET 5000 OPERATORS MANUAL 4 88 ...
Page 182: ...FERTILISER DISTRIBUTOR RAUCH AXERA H TEEJET 5000 OPERATORS MANUAL 4 124 ...
Page 194: ......
Page 253: ...TEEJET 5000 OPERATORS MANUAL SEED DRILL LEMKEN 5 59 ...
Page 254: ...SEED DRILL LEMKEN TEEJET 5000 OPERATORS MANUAL 5 60 ...
Page 276: ...BALER TEEJET 5000 OPERATORS MANUAL 6 8 ...
Page 278: ......
Page 291: ...TEEJET 5000 OPERATORS MANUAL SLURRY SPREADER OTHER TYPE 7 13 ...
Page 292: ...SLURRY SPREADER OTHER TYPE TEEJET 5000 OPERATORS MANUAL 7 14 ...
Page 350: ...FITTING INSTRUCTIONS TEEJET 5000 OPERATORS MANUAL 12 2 ...
Page 352: ...FITTING INSTRUCTIONS TEEJET 5000 OPERATORS MANUAL 12 4 GENERAL OVERVIEW ...
Page 365: ...TEEJET 5000 OPERATORS MANUAL FITTING INSTRUCTIONS 12 17 ...