               ATTENTION:  

 

Read the manual carefully before starting to use the control unit. Keep the instructions for future reference. 
 
  
                Do not open the device, touching any internal components can cause electric shock. Contact with 110-240 Volts 
AC can be fatal. To reduce the risk of electric shock, do not dismantle the back of the device for any reason. Moreover its 
opening would void the warranty. B

efore connecting the device to the power supply, make sure that all the 

connections are correct.

 Always disconnect the unit from the supply before any cabling modification. 

                 Any intervention on the equipment must be entrusted to a qualified repair engineer

         Failure to comply with these instructions can cause damages, fires or electric shock, and possible serious injuries! 

 

POWER SUPPLY

 

 

The VRT300 series can be supplied by 230Vac 50/60Hz o a 12Vac –Vcc, depending on the model purchased. 
Before using it, make sure the power cable is not damaged, kinked or pinched. Do not tamper with the power cable. Never 
disconnect the unit by pulling the cable, avoid touching the pins. Do not carry out any connecting/disconnecting with wet 
hands. To disconnect the device, do not use objects such as levers. Immediately disconnect the device if you smell burning 
or see any smoke: contact technical service.  

 

LIQUIDS

 

Do not expose the equipment to splashes or drops, do not position it in places with humidity exceeding 90% and never touch 
with wet or humid hands during storms. If any liquid penetrates the control unit, disconnect it immediately and contact 
technical service. 

 
CLEANING 

Disconnect the power cable before cleaning the control unit, use a dry cloth to dust it, without any solvent or detergents, and 
compressed air. 

 
OBJECTS 

Never insert any objects into the cracks of the control unit. If this happens, disconnect the control unit and  
contact an engineer. 

 
USE RESERVED TO QUALIFIED PERSONNEL 

The purchased goods are a sophisticated electronic device that is totally unsuitable to be used by non-qualified personnel. 
Any intervention must be carried out by a specialist engineer. 

 
ACCESSORIES 

The use of non-original accessories or spare parts might damage the unit and endanger users' safety.  In the event of faults, 
contact technical service. 

 
LOCATION 

Install the control unit indoors, in a place protected from water splashes and sun rays. Do not place near heat sources 
exceeding the parameters stated in this manual. Position on a stable surface, far from any possible vibrations. Position the 
unit as far as possible from any intense magnetic fields. 

 
REPAIRS 

Do not open the control unit. For any fault, always use qualified personnel. The opening of the control unit and/or the removal 
of the series identifying label entails the automatic forfeiture of the warranty. The Warranty seal is applied to all devices, any 
attempt to open the unit would break the seal and cause the consequent automatic forfeiture of the warranty. 

 
 

TECHNICAL INFORMATION  

 

Mail: [email protected] — tel: 02/4581861

 

 SAFETY REQUIREMENTS  

Summary of Contents for VRT300 Series

Page 1: ...ISO9001 2008 certified quality system http www tecsystem it R 1 0 16 09 13 Translations of the original instructions ENGLISH TECSYSTEM S r l 20094 Corsico MI Tel 39 024581861 Fax 39 0248600783 VRT300...

Page 2: ...NUAL IS VALID AND COMPLETE FOR THE VRT300 AND VRT300 U VERSIONS PAGE 1 SAFETY REQUIREMENTS 3 2 ACCESSORIES 4 3 TECHNICAL SPECIFICATIONS 5 4 FRONT PANEL 7 5 INSTALLATION 8 6 ELECTRICAL CONNECTIONS 9 VR...

Page 3: ...0 and never touch with wet or humid hands during storms If any liquid penetrates the control unit disconnect it immediately and contact technical service CLEANING Disconnect the power cable before cle...

Page 4: ...3 2 Supply and relay terminals 3 poles pitch 5 Code 2PL0367 1 motor line terminal 6 poles pitch 5 Code 2PL0372 1MN0030 REV 2 The above terminals are optional according to the configuration purchased A...

Page 5: ...max Connections on extractable terminal blocks OUTPUTS 1 fault sensor or operating failure FAULT relay SPDT Output relay with 5A 250Vac res COS 1 contacts 3 M1 M2 M3 outputs 250Vac max 10 5A max 50 6...

Page 6: ...C Humidity 90 non condensing Housing NORYL 94 _V0 Absorption 4VA max Electronic protection only on customer s request Polycarbonate IP65 front DISPLAY AND DATA MANAGEMENT LED s alarm undercurrent over...

Page 7: ...red 15 M1 motor in over current LED red 5 M3 motor in under current LED yellow 16 Current variation LED yellow 6 M2 motor in under current LED yellow 17 Fans local management LED red 7 Fixing block 18...

Page 8: ...eet 2 1 3 1MN0063 REV 0 1 Control unit 2 Panel hole dimensions 0 8mm tolerance 3 Identification label Fix the unit securely with the blocks supplied 1 2 3 4 1MN0008 REV 0 1 Control unit 3 Fixing screw...

Page 9: ...signal 2 Remote enabling contact ENABLE 5 Fan line supply 250Vac 10 15 amp max 50 60Hz 3 Control unit supply 230 Vac 10 50 60 Hz 4VA Note with the power to the unit ON the FAULT relay switches contact...

Page 10: ...AULT relay fault signal 2 Remote enabling contact ENABLE 5 Fan line supply 250Vac 10 15 amp max 50 60Hz 3 Control unit supply 12Vac dc 10 4VA Note with the power to the unit ON the FAULT relay switche...

Page 11: ...W TO CHECK THE ALARM STATUS Running LED OFF no ventilation activation control Running LED ON REMOTE or LOCAL ventilation activation Over and under current LEDs OFF motor operating correctly Over curre...

Page 12: ...lt 5 7 Motor start for automatic calibration CAL LED ON To perform the automatic calibration all motors must be connected as per final configuration At the START the motors are switched ON for 60 seco...

Page 13: ...M1 M2 M3 under current yellow LED ON Check the condition of the fans the cables and the supply Re program the device All the LEDs are flashing Memory error press RESET and repeat the programming proc...

Page 14: ...14 VRT300 SERIES TECHNICAL INFORMATION ufficiotecnico tecsystem it COMMERCIAL INFORMATION info tecsystem it PRODUCT INFORMATION CATALOGUES DOWNLOAD CONTROL UNIT MANUALS ACCESSORIES USEFUL CONTACTS...

Reviews: