NT210 K

 

 

 

 

 

 

                       

          ATTENTION:

 

 

Read the manual carefully before starting to use the control unit. Keep the instructions for future reference. 

 
  

              Do not open the device, touching any internal components can cause electric shock. Contact with voltage over  
50  Volts  can  be  fatal.  To  reduce  the  risk  of  electric  shock,  do  not  dismantle  the  back  of  the  device  for  any  reason. 
Moreover its opening would void the warranty. 

Before  connecting  the  device  to  the  power  supply,  make  sure  that  all  the  connections  are  correct.  A

lways 

disconnect the unit from the supply before any cabling modification. 

 

               

Any intervention on the equipment must be entrusted to a qualified repair engineer 

 

Failure  to  comply  with  these  instructions  can  cause  damages,  fires  or  electric  shock,  and  possible  serious 
injuries!

 

 

POWER SUPPLY

 

 

The NT210 K series has UNIVERSAL power supply, i.e. it can be supplied by 24 to 240 Vac-Vdc, irrespectively of polarity 
in Vdc.  
Before  using  it,  make  sure  the  power  cable  is  not  damaged,  kinked  or  pinched.  Do  not  tamper  with  the  power  cable. 
Never  disconnect  the  unit  by  pulling  the  cable,  avoid  touching  the  pins.  Do  not  carry  out  any  connecting/disconnecting 
with wet hands. To disconnect the device, do not use objects such as levers. Immediately disconnect the device if you 
smell burning or see any smoke: contact technical service.  

 

LIQUIDS

 

 

Do not expose the equipment to splashes or drops, do not position it in places with humidity exceeding 90% and never 
touch  with  wet  or  humid  hands  during  storms.  If  any  liquid  penetrates  the  control  unit,  disconnect  it  immediately  and 
contact technical service. 

 

CLEANING

 

 

Disconnect the power cable before cleaning the control unit, use a dry cloth to dust it, without any solvent or detergents, 
and compressed air. 

 

OBJECTS 

 

Never insert any objects into the cracks of the control unit. If this happens, disconnect the control unit and  
contact an engineer. 

 

USE RESERVED TO QUALIFIED PERSONNEL 

 

The  purchased  goods  are  a  sophisticated  electronic  device  that  is  totally  unsuitable  to  be  used  by  non-qualified 
personnel. Any intervention must be carried out by a specialist engineer. 

 

ACCESSORIES

 

 

The  use  of  non-original  accessories  or spare  parts might damage the  unit and  endanger users' safety.   In the  event  of 
faults, contact technical service. 

 

LOCATION 

 

Install the control  unit indoors,  in a  place  protected from  water splashes and sun  rays.  Do  not place near  heat sources 
exceeding the parameters stated in this manual. Position on a stable surface, far from any possible vibrations. Position 
the unit as far as possible from any intense magnetic fields. 

 

REPAIRS

 

 

Do  not  open  the  control  unit.  For  any  fault,  always  use  qualified  personnel.  The  opening  of  the  control  unit  and/or  the 
removal of the series identifying label entails the automatic forfeiture of the warranty. The Warranty seal is applied to all 
devices, any attempt to open the unit would break the seal and cause the consequent automatic forfeiture of the warranty. 
 
 

TECHNICAL INFORMATION 

 

 

Mail: [email protected] 

— tel: 02/4581861

 

 SAFETY REQUIREMENTS  

Summary of Contents for NT210 K

Page 1: ...ISO9001 2008 certified quality system http www tecsystem it R 1 5 31 01 18 Translations of the original instructions TECSYSTEM S r l 20094 Corsico MI Tel 39 024581861 Fax 39 0248600783 NT210 K TPL503...

Page 2: ...TY REQUIREMENTS 4 2 ACCESSORIES 5 3 TECHNICAL SPECIFICATIONS 6 4 TPL503 SENSOR INSTALLATION PROCEDURE 8 5 FRONT PANEL 10 DISPLAY 11 CHECKING THE WORK PROGRAM LED TEST ALARM RELAY TEST ALARM RELAY SILE...

Page 3: ...ORK RS485 ELECTRICAL CONNECTIONS DATA FRAME DATA PACKET FUNCTION CODE 21 CODE 3 10 CODE 16 10 NOTES FOR REMOTE PROGRAMMING ERROR CODES exception code POLLING FREQUENCY MODBUS MAPPING TABLE 22 CRC CALC...

Page 4: ...exceeding 90 and never touch with wet or humid hands during storms If any liquid penetrates the control unit disconnect it immediately and contact technical service CLEANING Disconnect the power cabl...

Page 5: ...itch 5 Code 2PL0359 Screws tightening torque 0 5Nm 1 RS485 terminal 3 poles pitch 3 81 Code 2PL0366 Screws tightening torque 0 25Nm 1 TPL503 sensor Tecsybus terminal 4 poles pitch 3 81 Code 2PL0368 Sc...

Page 6: ...h 131mm terminal block included Hole 92 x 92 mm TEST AND PERFORMANCE Construction in compliance with CE regulations Protection from electrical interference EN 61000 4 4 Dielectric strength 1500 Vac fo...

Page 7: ...temperature and pressure memory recorded since the last reset Front alarm reset button Sensor fault diagnostics FLT TPL503 TECHNICAL SPECIFICATIONS TPL503 POWER SUPPLY Direct connection to the Power...

Page 8: ...e from welding or painting residue and perfectly clean The cork rubber gasket TPL base must adhere fully to the support surface note replace the gasket every time it is removed to the TPL base NECESSA...

Page 9: ...air is released Attention bleeding must be carried out taking into consideration the transformer operating conditions with the transformer switched off and a temperature of about 20 C or ambient the i...

Page 10: ...7 FAN warning green LED 6 FAULT warning red LED 18 T P L alarm activation AL1 red LED 7 RS communication TPL503 green LED 19 T P L alarm activation AL2 red LED 8 Scanning mode selection button 20 T ma...

Page 11: ...are tested regularly For this operation press the TEST button briefly all the displays light up for 2 seconds ALARM RELAY TEST This function allows carrying out a test of the relay operation without...

Page 12: ...t 2 1 3 1MN0007 REV 0 1 Control unit 2 Panel hole dimensions 0 8mm tolerance 3 Identification label Fix the unit securely with the blocks supplied 1 2 3 4 1MN0008 REV 0 1 Control unit 3 Fixing screw 2...

Page 13: ...nector connection colours 1 RS white 2 PWL brown 3 PWL black 4 RS Blue Note with the power to the unit ON the FAULT relay switches contacts 8 9 open NO and 7 9 closed NC read paragraph ALARMS AND VENT...

Page 14: ...esholds are exceeded The FAULT relay switches when the unit is powered contacts 7 9 closed NC and 8 9 open NO and holds till one of the following events takes place Data storage fault Ech message TPL5...

Page 15: ...alteration of the programmed data at start up Ech is displayed with the relative warning of the Fault contact In this case for safety reasons the default parameters are loaded automatically see the pr...

Page 16: ...ds until the control unit is reset This operation will allow compensating for any reading tolerances due to differences in altitude or transformer filling pressure For the system to be operating corre...

Page 17: ...old is displayed 6 Set the desired threshold Default 100mbar 7 The pressure TRIP AL2 threshold is displayed 8 Set the desired threshold Default 200mbar 9 The level gas ALARM AL1 threshold is displayed...

Page 18: ...d Modbus transmission speed Default 9 6 Kb s 31 Set the desired speed From 2 4 Kb s to 38 4 Kb s 32 PAR datum is displayed Parity bit selection Default NO 33 Set the desired speed None No Even EVE Odd...

Page 19: ...evented as shown above Corrective actions check the installation of the sensor extension cable is in line with the instructions given in the paragraph on the TPL503 connections on page 15 Identificati...

Page 20: ...emperature reading mode while it is inactive when it is in the following modes display programming and relay test RS485 ELECTRICAL CONNECTIONS As to the signal cable to use in order to guarantee corre...

Page 21: ...00 17 00 18 00 24 The same must be remembered for the Trip thresholds registers 00 25 00 26 00 32 and for each quantity measured Temperature Pressure Level Note the Alarm level thresholds must be prog...

Page 22: ...er 1 2 3 see level indication page 16 00 05 00 TPL503 sensor temperature Holding register Temperature Range 40 120 DATA LO 50 10 00 06 00 Not used Holding register 00 07 00 Oil pressure Holding regist...

Page 23: ...ster 00 14 00 Not used Holding register 00 15 00 Not used Holding register 00 16 00 Not used Holding register 00 17 00 Oil Temperature Set Alarm Holding register C 00 18 00 Oil Pressure HI Set Alarm H...

Page 24: ...bled 00 29 00 Oil pressure Trip Holding register mbar 10 00 30 00 Not used Holding register 00 31 00 Not used Holding register 00 32 00 Not used Holding register 00 33 00 Hfn Holding register See page...

Page 25: ...45 00 Oil Temperature alarm history Holding register See note 2 on page 28 00 46 00 Oil Pressure alarm history Holding register 00 47 00 Oil Level alarm history Holding register 00 48 00 Not used Hold...

Page 26: ...olding register 00 60 00 Not used Holding register 00 61 00 Not used Holding register 00 62 00 Not used Holding register 00 63 00 Not used Holding register 00 64 00 Not used Holding register 00 65 00...

Page 27: ...00 Not used Holding register 00 80 00 Not used Holding register NOTE 1 STATUS REGISTER The status register contains information on the status of the alarms of the channel it refers to Each bit repres...

Page 28: ...NOTE 3 GENERAL FLAG REGISTER The general function register contains information on the enabling of general functions FLG_GEN GENERAL FLAGS B7 B6 B5 B4 B3 B2 B1 B0 FREE PRES DEP FREE SYSTEM FLAG ECH E...

Page 29: ...bytes in the packet excluding the 2 of the CRC G Polynomial 1010 0000 0000 0001 shr shift to the right ALGORHITHM 1 0xFFFF A 2 0 i 3 0 j 4 Di AL AL 5 j 1 j 6 shr A 7 if carry then G A A 8 if NOT j 8...

Page 30: ...roblem persists European directives 2012 19 EC WEEE and 2011 65 EC RoHS have been approved to reduce electrical and electronic waste and promote the recycling and reuse of the materials and components...

Reviews: