![TECSYSTEM NT210 K Instruction Manual Download Page 22](http://html1.mh-extra.com/html/tecsystem/nt210-k/nt210-k_instruction-manual_1073020022.webp)
22
NT210 K
MODBUS MAPPING TABLE
Address HI
(10)
Address LO
(10)
Data HI
Data LO
Primary tables
Notes
00
01
00
Oil temperature
Holding register
Temperature
Range
-40+120°
DATA LO
-50
(10 )
00
02
00
Oil pressure HI
Holding register
mbar see note
page 22.
00
03
00
Oil pressure LO
Holding register
mbar see note
page 22.
00
04
00
Oil level
Holding register
1-2-3, see level
indication page 16.
00
05
00
TPL503 sensor
temperature
Holding register
Temperature
Range
-40+120°
DATA LO
-50
(10 )
00
06
00
Not used
Holding register
00
07
00
Oil pressure
Holding register
mbar/10 see note
page 22.
00
08
00
Not used
Holding register
NOTE: The pressure is readable in the form of mB of 0 to 500 bytes of HI (register 2) and LO byte (register 3).
Or it is available in the form of mBar / 10 (single byte register 7).
The sign is present in bit 6 of the flag FLG_GEN register 49 (HI + sign pressure, LO sign - and then depressure).